Covid 19 test kits, forehead thermometers, ventilators, elisa reader washer, rt pcr.
We are the leading manufacturer, exporter and supplier of Oxygen Plants, Nitrogen Plants, Air Seperator Plants, Acetylene Plants, Nitrous Oxide Plants and Carbon Di-oxide Plants. O�ered in various capacities, sizes and other related speci�cations as per the preferences laid by our clients these products are manufactured by our skilled industry experts as per the set international standards. We also manufacture and export related Allied Equipment's and spares for the above stated Plants. PROCESS DESCRIPTIONS: Step1: Compression of Atmospheric Air Step 2: Puri�cation of Air Step 3: Cooling of Air Step 4: Separation of Liquid Air into Oxygen and Nitrogen. Step 5: Compression / Withdrawal and Filling of Oxygen and Nitrogen by latest liquid oxygen pump technology to �ll bone dry high purity oxygen in Cylinders. USES OF OXYGEN: Oxygen is obtained on a commercial scale through the liquefaction and desolation of ambient air at air separation plants. Oxygen (O2) is a colorless and odorless gas. It is vital for most life forms on earth. We absorb oxygen through the air we breathe. Medical oxygen is essential in hospital and clinical care for resuscitator and surgery and for various therapies. It is also mixed with nitrogen or helium to create underwater diving mixtures. FOR DETAILS: Please contact me for further details related to operation, installation and plant design according to client user requirements. Contact: BABAR SALEEM / Email: bew-uae@brooklyn-bh.com
Oxygen Lance Tubes Thermic Lance Tubes
Cutback Bitumen ( Liquid Bitumen ) is Bitumen that is dissolved in a solvent . Typical solvents include Naptha, gasoline and kerosene, white spirit etc. The type of solvent controls the curing time while the amount determines the viscosity of the Cutback Bitumen. The advantage Cutbacks have over Emulsions is a much higher residual Bitumen percent, typically over 80% compares with over 40-65% for Bitumen emulsions. The result is more Bitumen left on the roadway after curing, for the same volume of binder applied. Application Cutback bitumen’s suitable for primer sealing can also be used in the manufacture ofpre-mix asphalt, which is used in patch repairs.Cutback bitumen’s are used extensively in sprayed sealingapplications, particularly in cooler weather where theyprovide improved initial stone retention due to their Price of Product (USD) : 503 Product Origin : Merco W.L.L Bahrain Key Specifications / Special Features : Cutback Classification Cutbacks are divided into two classifications, Rapid-Curing (RC) and Medium-Curing (MC) depending on the solvent used. They are further defined by a number which indicates the minimum kinematic viscosity (fluidity) of the cutback. Grades & Properties Grade Curing Speed Viscosity Penetration of Residue MC 30 Medium 30-60 120- 150 MC 70 Medium 70-140 120- 150 MC 250 Medium 250- 500 120- 150 MC 800 Medium 800- 1600 120- 150 MC 3000 Medium 3000- 6000 120- 150 RC 70 Rapid 70-140 80- 120 RC 250 Rapid 250-500 80- 120 RC 800 Rapid 800- 1600 80- 120 RC 3000 Rapid 3000- 6000 80- 120 Minimum Order size and packgaing detail Palletizing is required for Cutback Bitumen & Emulsions -200kg drums shall be secured as 4 drums per pallet.
Ppe products,textile,agriculture,food,oil,packing, application services artificial intelligence automation business process outsourcing business strategy change management cloud customer experience data & analytics ecosystem partners finance consulting industry x infrastructure marketing mergers & acquisitions (m&a) operating models security supply chain management sustainability technology consulting technology innovation zero based budgeting (zbb), artificial intelligence blockchain cloud competitive agility covid 19 cyber security future systems future workforce industry x blogs podcasts, aerospace & defense automotive banking capital markets chemicals communications and media consumer goods and services energy health high tech industrial equipment insurance life sciences natural resources public service retail software and platforms travel utilities.
Safety shoes & coveralla / uniforms (for oil / gas plants, construction, facilities / cleaning / maintenance).
.Third paty inspection services, technical staff supply, ndt inspector supply
Data/voice/CCTV/wifi cabling, fiber optic cabling, splicing, testing, data and voice CAT5 & CAT6 cables, patch cords, patch panels, face plates, I/O modules, fiber optic cables, fiber optic patch cords, F.Optic patch panels, media converters, server room cabinets installation.
Medical Equipment S, Spare Parts, Plastic Granules.
Bitumen emulsion is a mixture of fine droplets of bitumen and water. But as the bitumen is a petroleum product it doesn’t mix with water and as it is sticky in nature, it doesn’t easily gets disintegrated into fine droplets. To overcome this problem an emulsifier is used. Emulsifier can be defined as a surface-active agent. Emulsifier keeps the bitumen in its fine droplet state by disallowing it to mix with other droplets. As the droplets are very fine they suspend in water. Therefore, bitumen emulsion is a dispersed liquid consisting of three products, i.e. water, bitumen and emulsion. Bitumen emulsion is a mixture of fine droplets of bitumen and water. But as the bitumen is a petroleum product it doesn’t mix with water and as it is sticky in nature, it doesn’t easily gets disintegrated into fine droplets. To overcome this problem an emulsifier is used. Emulsifier can be defined as a surface-active agent. Emulsifier keeps the bitumen in its fine droplet state by disallowing it to mix with other droplets. As the droplets are very fine they suspend in water. Uses Cationic emulsions may be used at ambient temperatures with aggregates, which need not be completely dry. Emulsions are less hazardous to use and can be applied in a wider range of conditions. Advantages a) Cationic emulsions may be used at ambient temperatures with aggregates, which need not be completely dry. b) Lower costs are incurred due to a considerable saving on fuel for heating purposes. c) Operating at lower temperatures for cold mixing gives a greater margin of safety, even though these emulsions may contain fluxing oil. d) Not only may cold mix be stockpiled for long periods, but it may also be packaged in small containers and stored. This facilitates the treatment of very small areas quickly, cleanly and economically. Disadvantages A regular water supply is required and this can be a great problem in very hot countries, where water can be in very short supply. Price of Product (USD) : 432 Product Origin : Merco W.L.L Bahrain Key Specifications / Special Features : Type Viscosity @25°C Penetration & Solubility Residue Tack Coat K1- 40 25 Max 60- 200 & (97.5) 38% Rapid Setting RS-1K 20-50 60- 200 & (97.5) 50% Rapid Setting K1-60 -NA & (97.5) 57% Rapid Setting CRS-160- 200 & (97.5) 60% Rapid Setting CRS-2-60- 200 & (97.5) 65% Rapid Setting K1-70NA & (97.5) 67% Medium Setting K2-NA & (97.5)57% Medium Settng CMS 2-60- 200 & (97.5) 65% Slow Setting K3 20- 100 60- 200 & (97.5) 56% Slow Setting CSS-1 20- 100 60- 200 & (97.5) 57% Minimum Order size and packgaing detail 16.00(=/-3%) Metric tons per 20 Foot Container. 200 kgs(+/-3kgs) in one drum.Total no of drums in 1 container 80
Benzene, xylene, toluene, naphtha,, methanol, kerosene, gas oil, white spirit, furnace oil, fuel oil,, base oil (virgin & recycle), used engine oil, light diesel oil, crude oil,, burner oil, light cycle oil, aromatics, pygas, caustic soda flakes (naoh) >99.5 % (dry basis), caustic soda lye (naoh) 50%,, hydrochloric acid (hcl) 31 33 %, sodium hypochlorite (naocl) 15%, calcium chloride anhydrous granules (cacl2) 94 97%, linear alkyl benzene sulphonic acid.
Test Parameters Method Unit Result Color Density 76.5 Flash
Test Parameters Method Unit Result Color Light Yellow Density 0.777 Approx Flash
Test Parameters Method Unit Result Color White Density 0.67 Flash
Test Parameters Method Unit Result Color Water white Density 76.5 Flash
Bitumen penetration grade 60/70 means the penetration value is in the range 60 to 70 at standard test conditions which commonly used as a Paving Grade. Bitumen is applicable for the production of hot mix asphalt for bases and pavements and for road construction.Penetration Grade Bitumen supplied by MERCO Bahrain. Its penetration grade ( the measure of bitumen hardness) is between 60 to 70. Bitumen is specified by the penetration and softening point test.Penetration determines the hardness of bitumen by measuring the depth to which a standard loaded the needle will vertically penetrate in 5 seconds, in a sample of bitumen maintained at a temperature of 25 degrees Celsius. Price of Product (USD) : 503 Product Origin : Merco W.L.L Bahrain Key Specifications / Special Features : Test Name Test Method Unit Result Specific Gravity @25°C ASTM D70 kg/cm³ 1.01-1.06 Penetration @25°C ASTM D5 mm/10 60/70 Softening Point °C ASTM D36 °C 49/56 Ductility @25°C ASTM D113 cm 100 min Loss on Heating (wt%) ASTM D6 wt% 0.2 max Drop in Penetration after heating % ASTM D5-D6 % 20 max Flash Point °C ASTM D92 °C 232 min Solubility in Trichlorethylene ASTM D2042 wt% 99 min Spot Test A.A.S.H.O.T102 Negative Minimum Order size and packgaing detail we will provide both 20FT as well as 40FT Containers (200 Liter per drum both open as well as closed top Drums), also in 1 MT flexi bags. Steel Drum Sizes Drum Size 200 kg Drum Height 980mm Diameter 520 550mm Thickness 0.6 –0.8mm
Iron oxides are widely used as inexpensive, durable pigments in paints, coatings and colored concretes. Product Origin : Merco W.L.L Bahrain Actual Chemical Analysis Results : Actual results tested by a competent laboratory on sample taken at load port with the following findings Specifications Results Fe 66.40 PCT FeO 13.12 PCT Sio2 2.79 PCT CaO 1.27PCT Al2O3 0.49 PCT P 0..32 PCT S 0.035 PCT CaO : Sio2 0.46 Moisture 0.12 PCT Size 0-3 MM 37.20 PCT 3-5MM 26.60 PCT 5-10MM 36.20 PCT
ECOFLAM BURNERS have Special Versions: Ecoflam is known for its ability to conceive and manufacture flexible products and to propose customized solutions able to find a solution to any type of request. The flexibility of the Ecoflam range makes it possible to guarantee a rapid response to each customer, even in the case of installations characterized by extremely high technical specifications. Satisfied customers and a history full of successes all over the world show that over the years Ecoflam has been able to work at the customer's service, offering a wide range of special products able to satisfy even the most complex needs. ECOFLAM Customized solutions for any type of application. The flexibility of Ecoflam solutions has enabled the introduction of a range of highly customizable products: from ECOFLAM family 12 kW to 80 MW.
Transformers (2 Units) Load tap switching transformer Standard JEC-220-2014 Phase number 3 Rated frequency 50Hz Cooling method ONAN / ONAF Rated Capacity (KVA) Primary 20000/22000 Secondary 20000/22000 Rated voltage (V) primary 66000 secondary 6600 Rated current (A) primary 175/192 secondary 1750/1925 Test voltage value (KV) primary L1 350 AC 140 secondary L1 60 AC22 Temperature rise limit Number of turns 65K Oil 60K 23T each in weight
Copper Refrigeration Tubes, Insulated Copper Kits, Pancake Coils, Level Wound Coils, Inner Groove Tubes And Refrigerants..