EZ9R36225 // Easy9 Residual Current Circuit Breaker - 2P - 25 A - 30 mA - AC type - 230 V EZ9F56232 // Miniature circuit breaker, Easy9, 2P, 32 A, C curve, 6000 A
Brands : Schnieder, Abb, Legrand, L&T, C&S, Chint, HPL, Hager, Havells, etc Current Rating : 6A to 125A No Of Poles : 2P, 4P Voltage Rating : 230 - 240 VAC, 230 VAC, 240 - 415 VAC, 400 - 415 VAC , 415 V Breaking Capacity : 6KA to 10KA Sensitivity (mA) : 30 mA to 500mA Buy RCCB online from India at wholesale rates. If you have been looking for Schneider, ABB, L&T, Siemens, Chint, havells, HPL, Hager etc RCCB dealers, your search ends here as you can get the best RCCB distributors in countries such as USA, UK, Australia, Sweden, Africa, Middleeast, Europe, Asia etc. You can purchase RCCB of the finest quality and rest assured to get the best in terms of both durability and performance. If you are bothered about the prices, you can be totally sure to get the best rates as brings you genuine Products.
More Information Brands : Schneider, Siemens, Chint, Havells, Abb, Hager, C&S, L&T, HPL etc HSN : 85362030 Number of Poles : 1, 2, 3, 4 Poles Current Rating (Amp) : 0.5 A to 125A Curve : B Curve, C Curve, D Curve Frequency Rating : 50/60 Hz
Vcb best quality having topmost brands available here Brands : Siemens, Abb, Schnieder, Havells, Kirloskar, BCH, Bharat Bijlee etc Out door and Indoor Type Of Breaker: Vcb Rated Bus Bar Current: 630, 1250A / 630, 1250, 1600, 2000, 4000A Rated Voltage: 11Kv /12kv/33kv/ 36Kv Short Time Withstands Current: 16Ka, 26.3Ka / 25Ka-40Ka
Features Type : MCCB Number of Poles :1, 2, 3, 4 P Breaking Capacity (kA) :10 to 100kA Trip Type :Thermal Magnetic Trip/ Microprocessor Brands : Siemens, C&S, Schnieder, L&T, ABB, Chint, Havells, Hager, HPL etc
Conforms to IEC 60947-2 Accurate protection through microprocessor based trip unit & Thermal magnetic Unique ready-to-close interlock for maximum safety Mechanical contact erosion indicator Fully rated upto 55 degree C Neutral 100% rated Standard breaking capacity Ics = 100% Icu Fixed/Drawout Brands : Schnieder, Siemens, Abb, Legrand, L&T, C&S, Havells, Chint etc No. of Poles : 3 & 4 Current Rating : 400A to 6300A EDO & MDO
Safety plug-If the wiring of the device is loose, the electrical device becomes dangerous. The OAONAN Safe RCD connector can help you by detecting current leakage current and stopping power supply within 100ms. Protect you from injury or even fatal electric shock Fully compatible-suitable for any standard socket. Compatible electronic equipment (220V-240V) Passed CE certification-composed of non-conductive and fire-resistant PC material. The sturdy design is suitable for indoor and outdoor use. For example, in high temperature, humidity and other harsh environments Wide range of uses-suitable for kettles, electric blankets, power tools, lawn mowers, Christmas lights, hedge trimmers, etc.
MCB 6A to 63 A - 6KA & 10KA : - 1P, 1PN, 2P, 3P, 3PN,4P.
Double Door Ready to use DBs â??IP43 Protection available, Provided with 100A insulated phase bus-bar/neutral bar with shroud/earth bar/sticking saddles/ cement spill protector/color-coded Interconnecting wire set/cable ties/blanking plates and circuit identification label. With provision for DP MCB/Isolator/RCCB/RCBO as incomer and SP MCBs as outgoing.
WSD-ZW32-24D Outdoor AC high voltage vacuum circuit breaker (hereinafter referred to as circuit breaker) is a rated voltage of 24 KV, 50 HZ three-phase AC outdoor distribution equipment.The utility model has the advantages of stable and reliable interruption performance, no danger of combustion and explosion, maintenance-free, small size, light weight and long service life.It is mainly used for breaking and closing the load current, overload current and short circuit current in power system.It is suitable for protection and control in power distribution systems of substations and industrial and mining enterprises, and more suitable for rural power grids and frequently operated places. This product meets GB1984-2003 "High Voltage AC Circuit Breakers" and DL/T402-2007 "Technical Conditions for Order of High Voltage AC Circuit Breakers" and DL/T403-2000 "Technical Conditions for Order of 12 kV~40.5 kV High Voltage Vacuum Circuit Breakers" and other technical standards.
CHARACTERISTICS 1. The vacuum arc extinguishing chamber uses longitudinal magnetic field arc extinguishing technology, which has the characteristics of long electric life and high reliability. 2. The imported silicone rubber/epoxy resin for outdoor use and the present APG vacuum injection technology are adopted. 3. Anti-ultraviolet, moistureproof, anti-corrosion, with the advantages of preventing surface discharge, good hydrophobicity and high mechanical strength. 4. Using simple and reliable spring operating mechanism, it has the advantages of small size and light weight. 5. high voltage vacuum circuit breaker can be equipped with isolation switch and three-phase linkage. It has visible breaks when the isolation switch is switched off. It also has anti-mistake interlock between the isolation switch and the circuit breaker body. It can be equipped with arrester strut insulators. Operational sequence When operating the disconnector, the first step is to confirm that the circuit breaker should be in the open state. Use the insulated tie rod hook to fasten the closing pull ring or the opening pull ring of the operating handle of the isolation closure, pull down slightly, drive the spindle to rotate, open or close the isolation switch. When the spindle rotates the dead point position of the compression spring, a certain tension is maintained so that the blade can be reliably closed or opened to a safe isolation position.
Circuit breaker The circuit breaker mainly serves for protecting the circuits of ac 50 hz, 230vof single pole, 230v/400v of two poles and 400v of three or four poles from overload or short-circuit, and also for unfrequent making and breaking electrical apparatus and lighting circuit. Packed in export cartons
IPCE Circuit Simulator Product Introduction IPCE Circuit Simulator is TDM OVER IP Device. As long as the IP address of two terminals can recognize each other, then this device can transmit E1 signal via IP network readezvous point and can achieve join monolithically with existing TDM Terminal, Such as PSTN connection, ATM, Frame relay, ISDN, concentrated user exchange and so on. Provides various operation of TDM directly and don't need change any Terminal. Product Feature 1. Transmit frame or unframed E1 signal via IP net, Filly compatible with G.703 2.High transmission rate and low transmission delay 3.Clock revert stably, small dithering and excursion 4.Possess QoS guarantee, supports transmit with date at the same time, assure E1 date prior transmission 5.Convenient to use, don't need complex setting 6. Transmission package look for address base on IP address and can be configured and revisable 7. Transmission package base on IP date package, shield specific transmission medium, not only can be used in Ethernet /Token-ring or other wired network, but also can be used to increase point to point TDM of wireless LAN. Even can be used in network which mix with wired and wireless 8 Developed a echo counteract device to E1 that it can cancel echo of outside 128ms for some IP transmission network delay is too large and echo problem in voice communication Setting and Diagnosis 9 IPCE provides menu mode setting service, convenient to use 10 IPCE provides long-distance login connector to set long-distance device via telnet 11 IPCE supports dynamic upgrade, when download new software edition, the old software will be save in backup section. so, if new software be damaged, system can still use old software 12 System provides various alarm: LOS, AIS, LOF and so on 13 IPCE provides local startup auto-inspection, and the inspection result can be observe via super terminal 14 IPCE provides statistic of network affair: date package lose, date package delay, date package wobble and so on Technologies reference 15 LAN interface: Port standard: IEEE802.3,IEEE802.3U Port type: RJ45 Port mode: Auto-adapt to 10/100M Protocol: CSMA/CD 16 E1 interface: Line code: HDB3 Bit rate: 2048KBIT/S+-50ppm
4p 1000V DC Solar Mini Circuit Breaker Description: PQB1Z-63 4P PV DC breaker supplementary protectors are designed to provide overcurrent protection within appliances or electrical equipment, where a branch circuit protaction is already providedd or not required. Devices are designed for direct current(DC) control circuit applications. Technical Parameter: Item DC MCB Code PQB1Z-63 Pole 1P 2P 3P 4P Voltage 250VDC 550VDC 800VDC 1000VDC Current 1A,3A,6A,10A,16A,20A,32A,40,50A,63A Standard IEC/EN60947 Breaking Capacity 6KA,10KA Characteristic Curve B,C,D Working Temperature "-5°"to +40° Protection Degree IP20 Electrical life More than 8000times Mechanical life More than 2000times Dimension(W)X(H)X(D) 18X80X71 36X80X71 54X80X71 72X80X71 Installation 35MM DIN RAIL Accessory YES Installation Altitude â?¤2000M
3P 800V DC solar mini circuit breaker Description: PQB1Z-63 2P PV DC breaker supplementary protectors are designed to provide overcurrent protection within appliances or electrical equipment, where a branch circuit protaction is already providedd or not required. Devices are designed for direct current(DC) control circuit applications. Technical Parameter: Item DC MCB Code PQB1Z-63 Pole 1P 2P 3P 4P Voltage 250VDC 550VDC 800VDC 1000VDC Current 1A,3A,6A,10A,16A,20A,32A,40,50A,63A Standard IEC/EN60947 Breaking Capacity 6KA,10KA Characteristic Curve B,C,D Working Temperature "-5°"to +40° Protection Degree IP20 Electrical life More than 8000times Mechanical life More than 2000times Dimension(W)X(H)X(D) 18X80X71 36X80X71 54X80X71 72X80X71 Installation 35MM DIN RAIL Accessory YES Installation Altitude â?¤2000M
2P 500V DC solar mini circuit breaker Description: PQB1Z-63 2P PV DC breaker supplementary protectors are designed to provide overcurrent protection within appliances or electrical equipment, where a branch circuit protaction is already providedd or not required. Devices are designed for direct current(DC) control circuit applications. Technical Parameter: Item DC MCB Code PQB1Z-63 Pole 1P 2P 3P 4P Voltage 250VDC 550VDC 800VDC 1000VDC Current 1A,3A,6A,10A,16A,20A,32A,40,50A,63A Standard IEC/EN60947 Breaking Capacity 6KA,10KA Characteristic Curve B,C,D Working Temperature "-5°"to +40° Protection Degree IP20 Electrical life More than 8000times Mechanical life More than 2000times Dimension(W)X(H)X(D) 18X80X71 36X80X71 54X80X71 72X80X71 Installation 35MM DIN RAIL Accessory YES Installation Altitude â?¤2000M
1P 250V DC solar mini circuit breaker Description: PQL7 PV DC breaker supplementary protectors are designed to provide overcurrent protection within appliances or electrical equipment, where a branch circuit protaction is already providedd or not required. Devices are designed for direct current(DC) control circuit applications. Technical Parameter: Item DC MCB Code PQB1Z-63 Pole 1P 2P 3P 4P Voltage 250VDC 550VDC 800VDC 1000VDC Current 1A,3A,6A,10A,16A,20A,32A,40,50A,63A Standard IEC/EN60947 Breaking Capacity 6KA,10KA Characteristic Curve B,C,D Working Temperature "-5°"to +40° Protection Degree IP20 Electrical life More than 8000times Mechanical life More than 2000times Dimension(W)X(H)X(D) 18X80X71 36X80X71 54X80X71 72X80X71 Installation 35MM DIN RAIL Accessory YES Installation Altitude â?¤2000M
circuit breaker position indicator with symbol place of origin : Zhejiang Province,China(Mainland) brand name : NIN type : AD16-22W/D color : white green red yellow blue lamp voltage : DC/AC 6V 12V 24V 36V 48V 110V 220V 380V lamp life : more than 30000 hours IP rating : IP65 If you are interested in our products,please contact us, we will reply you as soon as possible. Tel:+86 0577-61718928 Fax:+86 0577-61718928 Mobile: +86 15057787869(Whatsapp/Wechat) Email:tess@yq.nindq.com Webiste: www.nindq.com
F 200 A type with neutral pole on the left Function: protection against the effects of sinusoidal alternating and direct pulsating earth fault currents; protection against indirect contacts and additional protection against direct contacts (with In=30 mA). Product helpful where for installation habits, for wiring with busbars or cables, for special needs neutral on the left is needed. Application: residential, commercial, industrial. Standard: IEC/EN 61008-1; IEC/EN 61008-2-1 Marking: according to EN 61008-1; EN 61008-2-1 F204 A-25/0.03 F204 A-40/0.03 F204 A-63/0.03 F204 A-80/0.03 F204 A-100/0.03 F204 A-125/0.03 F204 A-25/0.1 F204 A-40/0.1 F204 A-63/0.1 F204 A-25/0.3 F204 A-40/0.3 F204 A-63/0.3 F204 A-80/0.3 F204 A-100/0.3 F204 A-125/0.3 F204 A-25/0.5 F204 A-40/0.5 F204 A-63/0.5
Specifications Description: Very fast-acting, currentlimiting fuse. Dimensions: See page 12 for Class Tdimensions. Construction: Melamine tube with silverfuse element. Ratings: Volts 300Vac (or less) 160Vdc (15-600A) 170Vdc (601-1200A) Amps 1-1200A IR 200,000 RMS Sym. 20,000A dc @ 160Vdc 100,000A dc @ 170Vdc Agency Information: CE, Std. 248-15, Class T, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787. Features and Benefits Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer. Current limitation for non-inductive circuits provides Class T current-limiting response to maximum ground fault and short-circuit conditions. 200,000A interrupting rating provides high ratings at all circuit locations. Small footprint allows more efficient use of available space. Typical Applications Large Apartment Complexes Multi-Family Meter Stacks VFD Line Protection JJN-1 JJN-2 JJN-3 JJN-6 JJN-10 JJN-15 JJN-20 JJN-25 JJN-30 JJN-35 JJN-40 JJN-45 JJN-50 JJN-60 JJN-70 JJN-80 JJN-90 JJN-100 JJN-110 JJN-125 JJN-150 JJN-175 JJN-200 JJN-225 JJN-250 JJN-300 JJN-350 JJN-400 JJN-450 JJN-500 JJN-600 JJN-700 JJN-800 JJN-1000 JJN-1200