ALSTOM GBCDG61EG040SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Relay Technical specification Relay model no CDG61EG040SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Aux.Contacts With Flag 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set conts.With flag CAG 13 / 2M S/R Name plate RFG9125 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG041SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG041SGCH Relay type CDG 61 Case size 3D H 30T Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set CAG 13 Name plate RFG9126 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG042SHCH IDMT 2 O/C & 1 E/F RELAY WITH HIGH SET Technical specification Relay model no- CDG61EG042SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 2M2B H/R 2M S/R Output contacts - 2M2B H/R 2M S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 0.2 to 0.8 amps High set - O/C Setting- 4 to 16 amps High set - E/F Setting - 1 to 4 amps High set - CAG 13 Name plate - RFG9126 902 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG044SHCH IDMT 3 O/C RELAY WITH HIGH SET CAG 13 Technical specification Relay model no - CDG61EG044SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 3 O/C Current setting - 0.5 to 2 amps Contacts / Output contacts - 2 N/O 2 N/C H/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs High set - O/C Setting - 4 to 16 amps High set - CAG 13 High set contacts - 2 N/O S/R Name plate - RFG9126 771 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG046SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no - CDG61EG046SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting O/C- 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 1 to 4 amps High set - O/C Setting- 25 to 100 amps High set - E/F Setting- 10 to 40 amps High set - CAG 13 Name plate - RFG9126 904 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG054SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG054SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden / Operating time - 3 VA / 1.3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 2 to 8 amps High set CAG 13 Name plate RFG9125 902 Outline drawing MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG057SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG057SGCH Relay type - CDG 61 Case size - 3D HOR. Application - 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R C.T.Secondary 1 amps Frequency 50 Hz Burden / Operating time 3 VA / 3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 1 to 4 amps High set CAG 13 Name plate RFG9126 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG058SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG058SGCH Relay type CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 2.5 to 10 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden / Taps - 3 VA / Std Operating time - 1.3 Secs Current setting - E/F - 0.5 to 2 amps High set - O/C Setting - 25 to 100 amps High set - E/F Setting - 10 to 40 amps High set / High set cont. - CAG 13 / 2 N/O S/R Name plate - RFG9125 903 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
Gbcdg61eg101zmch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zm(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o S/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c Setting - 2.5 - 10 Amps. Name Plate - Rfg9126 774 Outline Diagram - Mfj 014 Wiring Diagram - Madz821.31
Gbcdg61eg101znch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zn(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o 2 N/c H/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c or O/v Setting - 2.5 - 10 Amps. Name Plate Rfg9126 774 Outline Diagram Mfj 014 Wiring Diagram Madz821.32
GBCDG61EG101ZRCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical Specification Model No - CDG61EG101ZRCH Relay Type - CDG61/CAG17(MRK-III) Application - 2 O/C + 1 E/F Case Size - 3D Horz C.T. Secondary - 5 Amp C.T. O/C Setting - 2.5 - 10 Amps. E/F Setting - 0.5 - 2 Amps Contacts - 2 N/O S/R Flag - Yes Frequency - 50 Hz Burden / D.M.T - 3 Va / 3 Sec High Set Type / Conts. - CAG17 / 2 N/O S/R Highset O/C Setting - 12.5 - 100 Amps. HighSet E/F Setting - 5 - 40 Amps Mounting - Flush Name Plate - RFG9126 903 Outline Diagram - MFJ 014 Wiring Diagram - MADZ821.31
GBCDG61EG101ZSCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI TECHNICAL SPECIFICATION Model No - CDG61EG101ZSCH CDG61/CAG17(MRK-III) Application - 2 O/C + 1 E/F Case Size - 3D Horz C.T. Secondary - 5 Amps O/C Setting - 2.5 - 10 Amps. Frequency / Tap - 50 HZ / Std Burden / D.M.T - 3 Va / 3 Sec Contacts - 2 N/O 2 N/C H/R E/F Setting - 0.5 - 2 Amps. Flag - Yes High Set Type / Contacts - CAG17 / 2 N/O S/R HighSet E/F Setting - 5 - 40 Amps HighSet O/C Setting - 12.5 - 100 Amps. Mounting - Flush Name Plate - RFG9126 903 Outline Diagram - MFJ 014 Wiring Diagram - MADZ821.32
GBCDG61EG102ZMCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Model No : CDG61EG102ZMCH CDG61/CAG17(MRK-III) APPLICATION - 3 O/C BURDEN - 3 VA C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O S/R D.M.T - 3 SEC. FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET O/C SETTING - 2.5 - 20 Amps. MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. Name Plate RFG9126 771 Outline drawing MFJ 014 Wiring Diagram MADZ821.31
ZJJ DC insulation monitoring relay monitorsthe insulation of the DC bus, and it sendsalarm signal when the bus-to-groundinsulation drops to a certain value,also it ispanel mounted type,and the relay has a high-sensitivity grounding resistance monitoringand display circuit, it is great significance forthe safe operation of the DC system. Monitoring of the DC circuit bus barinsulation resistance RF to LCD screen display resistance value. Bridge balance method for resistancemeasurement. Adjustable response value ranges of 0-100k�©. Smaller short-circuit grounding current forsafe operation.
AFR arc flash protective relay is a costeffective solution that reduces arc-fault damage by detecting the light from an arc flash and rapidly tripping in low-voltage (LV) and medium-voltage (MV) electrical networks. three remote light sensors can be connected to one relay. It used to limits damages to equipment, improve safety, avoid and protect personnel injuries. It's also can be used as a stand-alone arc protection relay or applied in more complex switchgear layouts.
Three phase 100A Latching relay TP41-10: -Three phase 100A switching capability ; -Multi layer blades, lower temperature rise ; -Conform to fault making capacity and short circuit current; -carrying capacity of requirement of IEC62066-31( UC3) and IEC61810-1. -It can be applied in three phase 100A electricity meter.
Single phase 80A Latching relay TP41-26: -Single phase 80A switching capability ; -Multi layer blades, low temperature rise ; -Environment protection ( Comply with ROHS) -It can be applied in single phase or three phase 60A Electricity meters.
Deyang YOYIK strong technical force, with CNC lathes, machining centers, 1.6M vertical lathe, 2.5M vertical lathe, 3.2M vertical lathe, 4M vertical lathe, CNC boring machine, gantry planing, gantry milling, 80mm Bending Machine and other sophisticated equipment, Strong welding capacity. Deyang YOYIK also long-term supply of power plants, steel accessories are as follows: YOYIK provides multiple types of spare parts and equipments for power plant : #DF-Relay WDZ-5271-DF Displacement Sensor(LVDT) TDZ-1E-32oil station globe check valve J15C-1.6P Oil filter fluid transfer pump YW100-250 solenoid directional valve 4WE10Y-3X/CG24N9K4 axial piston variable pump PVH098R01AJ30A250000002 O ring HY.SO.0048.V mechanical seal for pump 125-80-250 RTD temperature probe WZP2-231 pressure hose SMS-15/N1/4-915mm-C screw pump diagram HSNH440-46NZ Electric Valve 3 wire thermocouple TC03A2-KY-2B/S15 transfer pump vane F3-SV20 Temperature sensor, Pt100 WZPK2-338S Filter element SDSGLQ-68T-40 Filter element SRA-14413-T pressure hose S110-AC-FB-0150 furnace thermocouple WRNK2-231-R1/4\K pipe panel 7500mm globe throttle check valve KJC25-2.5P temperature thermocouple TE-104 three screw pump ACF090N41RBP sealing ring HB4-56J8-177 CV Disc rotary vane vacuum pump F3V201S8S1C11 oil change pump 50AY35*12 thermocouple range TE-203 coupling RE.0444R1B 0.06 EG heater thermocouple WRNK2-0901T �?5 Oil filter element outlet end of EH oil pump flange coupling 125LY-23-8 pressure hose S100-AC-AC-0080 vacuum oil pump 125LY-35-4B REGULATING VALVE DISC Thermocouple Control WRNK2-346 Relay WDZ-5271 vane vacuum pump F3-V10-IS6S-1C-20 Globe valve J61Y-320 high pressure oil pump 50SDZLJ-50 chemical centrifugal pump DFB100-65-260-03 servo valve 72559A oil station globe check valve J50C-1.6P Network Switch EKI-2528ceramic thermocouple WRNK2-331 Electrical Epoxy Insulating paint 188 Heating rod ZJ-20-3 vacuum pump 264v P-2037 thermocouple replacement TC03A2-KY-2B/S19 centrifugal pump YCZ50-250 ELECTRICAL LINEAR VARIABLE DIFFERENTIAL TRANSFORMER 1000TD Accumulator Spare parts NXQ-A-40/31.5-L-Y rtd thermocouple WRN2-239 0-600â?? screw pump manufacturer ACF080K41RBP vane pump parts F3V10-1S6S-1C20 thermocouple protection tube WRNK2-221 piston pump hydraulic PVH131Q1C.RSF.10.C25 vacuum pumps P-1758 thermocouple wzpk 230 pt100 WRNK2-391 pressure switch 1RN-EE45-M4-C1Abalanced vane pump F3-20V5A-1C22R thermistor TE-204 thermocouple k type WRNKB-446S/TG thermocouple thermometer TE-404 furnace thermocouple TC03A2-KY-2B/S3 hydraulic piston pump 80AY50*6 Relay WDZ-5271 DFYL-2022-3-17-ZYR
Deyang Dongfang Yoyik is a professional company dedicated to the production, development, sale of power plant spare parts and accessories. Our company has strict requirements to ensure all our products meet the needs of customers. Through more than 20 years of efforts, the majority of customers have been fully recognized. Look forward to your emails and inquiries. Your satisfaction is our greatest comfort. YOYIK provides multiple types of spare parts and equipments for power plant : #DF-Relay GR-2C-AC230V-DF Globe valve J961Y-64I SWITCH PRESSURE 101NN-EE3-N4-C1A Globe valve J961Y-16P radial piston pump hydraulic PV29 2RID CO2 mechanical seal in pump CM104-45 water pump YCZ65-250B SENSOR, TEMPERATURE WRKK2-221 thermocoupl 1000â?? WRN2-239 twin screw pump HSNS210-54NZ Seal ring Sheathed thermocouple WRNK2-0901T �?5 pumps parts hydraulic 80AY-50X10 vaccum pump 30SPEN TC Sensor TE-204 Two-Color water Level Gauge Accessories SFD-SW32-(ABC) vacuum pump price P-1759 thermocouple voltage WRNKB-446S/TG Vent piping YOT51-20-00 vaccum pump SW-30 ksb pump centrifugal 65-250A burgmann mechanical seal N.D.E L270 mechanical shaft seal BF108-45u pump vacuum 30-WS P-2811 thermocouple type k WREK2-191 vacuum pump compressor P-2412 Thermocouple Cylindrical sensor WRNK2-346 mechanical seal 31 mm 11-SHF11/135-E10-A3 00 11 Resistance Thermometers WREX-001 vacuum pump oil P-1945 thermocouple type k WRN-332NM globe throttle check valve KJC25C-1.6P three screw pump HSNH440-46NZ thermowell WRNK-221Filter Element QTL-6027A.02 LCD Screen of Coal Feeder M402SD07G thermocouple digital WRN-330 Relay GR-2C-AC230V vacuum pump oil P-1753 Servo Moog Model : G771K202A VACCUM CIRCUIT BREAKER ZN63-VS1-2000-40KApt100 thermocouple TE-111 Oring mechanical seal pump 108-45 multistage centrifugal pumps CZ65-200 Position Sensor of Guide Vanve GEFRAN LT-M-0225-Pthermocouple wzpk 230 pt100 WPNKZ-630 thermowell flange TE-105 thermowell flange TE-404 rotary vane vacuum pump F3-20V12A-1C22 magnetic coupling centrifugal pump KSB50-250-007 hydraulic screw pump 3GR25*4-2.0/1.0 Current Transformer LBJ1-900A/10V Displacement sensor (LVDT) DET200Ametering piston pump SY400-YB-22 hand valve J61Y-P55 170V DN25 Platinum-Iridium Wire WREX2-001 Control Concepts Z6206052 Seal Oil Pressure Switch 6SC-KK5-N4-C2A Surface Thermocouple WREK2-230 Valve Z961H-64 DN200 metering piston pump Type K Thermocouple Cartridge WREX-001 O-ring HZB253-640-03-09 part no.:39 HP Back up Pump 2CY-45/9-1A transfer pump oil SDH150-125-400 Platinum Thermocouple Wire TE-403 Relay GR-2C-AC230V DFYL-2022-3-15-ZYR
India Thermal Power THERMAL OVERLOAD RELAY ZB32-1.6 Dongfang Yoyik Engineering Co., Ltd is located in Deyang, Sichuan, provides different kinds of industrial products and brands. Our company is specialized in researching and developing hear-resisting and wear-resisting materials. As a pump and valve manufacturer ourselves, we also offer other brands both domestic and from abroad. YOYIK provides multiple types of spare parts and equipments for power plant : #DF-THERMAL OVERLOAD RELAY ZB32-1.6-DF Spare Part Kit DN50 three screw pump ACG070K7NVBP Pressure filter element HP065-1-A10AN rtd thermocouple WRNK2-331 thermocouple wzpk 230 pt100 TE-107 Gasket item 6 2730-13-02 mechanical seals DZXB870-R67 screw pump diagram 3GR30X4W2 STEM D74.16B thermowell TE-108 dc screw pump 3GR30X4W2 axial piston pump PVH131QIC-RSF-13S-11-C25-31 centrifugal pump parts DFB100-65-230 vacum pump air vacuum KZ100-WS pump screw ACF080K5IVBP Accumulator HOPPECKE 3 OSP.HC105 Platinum Wire WRNK2-191M vacuum oil pump ZS-185A rotary vane pump F3V10-1S6S-1C20 Thermocouple Assemblies WRKK2-221 three screw pump 3Gr70Ã??2 thermocouple protection tube WRNR2-12 solenoid valve 24EI1-H6B-T pressure hose SMS-10/12-305mm-C pt100 rtd probe thermowell TE-205 thermocouple cable WRKT2-11 THERMAL OVERLOAD RELAY ZB32-1.6 thermocouple thermometer WREX2-001 electric oil transfer pump 50IY50A solenoid relief valve DBW10B-1-30/100UG24NZ5L Check valve 216C15 o-ring 140X3.55 EH oil feeder D1000A-690500B screw pump working principle HSNH280-43N7 3 wire thermocouple WREKD2-04 manual vacuum pump 30-WS thermocouple k WRNN2-4325 hydraulic vane pump F3-SDV10-1B7B-1A THERMOMETER WTY-1021 electric centrifugal pump head SDH200-150-315 type k thermocouple WREK2-294 screw pump working 3GR30*4 Globe valve J61Y-100 DN25 HYDRAULIC PUMP PD060PC02SRS5AAM0E1200000 bellows globe valve core WJ40F1.6P.03 Filter element BR110+EF4-50 Network Switch EKI-2528 vacuum pump 265v P-2332 rotary vacuum pump P-1964-1 Ignition set XDH-20C rotary piston pump PV2R3-76-RBAF1 fuel pump YH50-32-160 axial piston pumps PVH074R01AB10A2500000001E010A electric vacuum pump P-2335 THERMAL OVERLOAD RELAY ZB32-1.6 DFYL-2022-3-8-ZYR