Please click here to check who's online and chat with them.

Find Verified Electric Contactors Suppliers, Manufacturers and Wholesalers

Sep-06-17
 
Variable Vacuum Capacitor CKTB750/28/220
vacuum capacitor CKTB750/28/220 Cross reference
Jennings Type: CVFP750-40S

comet old type: CV2C-750E/40
comet new type: CVMA-750AC/40-AAB
The CKTB750/28/220 capacitor use vacuum as dielectric with ceramic envelope ,which have the following features:High voltage , Small size , High Q value, Stabilization capability , High reliability ,Low price.
The capacitor is Variable ceramic vacuum capacitors widely used in influence heating ,medium heating ,the equipments for communication transmitters and broadcasting etc.
Sep-05-17
 
Chv-450/3.6(1.14) contactor has the same performance and function with baker ac contactor, while it's more aligned with chinese national standards on some parameter index, contactor has independent drive with insolating function and the ability of breaking short time current. It has current/voltage mutual inductor which can realise the zero-current-break and comprehensive protection function; adopt quick pipe connection mode which is easy to use and maintain; highly integrated with small size and compact structure.
Sep-06-17
 
Variable vacuum capacitor cktb500/10/100(
Cktb500/10/100( vacuum capacitor cross reference
Jennings type: csvf 500-0315

Comet old type: cv1c-500t/15
Comet new type: cvve-500ac/15-bca-m
The cktb500/10/100( capacitor use vacuum as dielectric with ceramic envelope , which have the following features:high voltage , small size , high q value, stabilization capability , high reliability , low price.
The capacitor is variable ceramic vacuum capacitors widely used in influence heating , medium heating , the equipments for communication
Aug-17-16
 
HVJ3 12KV VACUUM CONTACTOR
Detailed product description:
The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 12kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear.

Working condition:
1) Altitude should not be over 1,000m;
2) Ambient temperature: -5~40°C;
3) Average temperature in 24 hour not exceed 35°C;
4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%;
5) Pollution degree: class 3

.Main models and technical parameters
Rated voltage: 12 KV
Control voltage: 220/110/380
Rated current: 160A, 250A, 400A, 630A
Clearance: 5±0.5 mm
Over travel: 2±0.2 mm
Pressure: >85N
Main circuit power frequency withstand voltage: 42000 v
Auxiliary circuit power frequency withstand voltage: 2500 v
Control circuit power frequency withstand voltage: 2000 v
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit opening current(A): 10Ie
Overload: 8Ie,10 s
Mechanism life: 1 million times
Weight: 30KG
Note: “Ie” represents the rated current of main circuit
Aug-17-16
 
1. General
HVJ5 1.14kv 125A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1,140V and rated current to 125A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on.
2. Main technical parameter
Rated voltage: 1140 V
Control voltage: 36V, 110V, 220V, 380V
Rated current: 125A
Opening distance: 1.8±0.2 mm
Over travel: 1±0.2 mm
Final pressure: 30±3 N
Main circuit power frequency voltage withstand: 4200 V
Auxiliary circuit power frequency voltage withstand: 2500 V
Control circuit power frequency voltage withstand: 2000 V
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit breaking current(A): 2000,3 times
Electricity life times AC3: 60*104
Electricity life times AC4: 60*104
Mechanical life times: 300*104
Overload capacity: 8Ie 10 S
Remark: “Ie” is Rated current of main circuit.
339 Electric Contactors Suppliers
Short on time? Let Electric Contactors sellers contact you.
Aug-17-16
 
1. General
HVJ5 1.14 kv 250A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1140V and rated current to 250A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on.
2. Main technical parameter
Rated voltage: 1140 v
Control voltage: 36V, 110V, 220V, 380V
Rated current: 250A
Opening distance: 2±0.2 mm
Over travel: 1±0.2 mm
Final pressure: 30±3 N
Main circuit power frequency voltage withstand: 4200 V
Auxiliary circuit power frequency voltage withstand: 2500 V
Control circuit power frequency voltage withstand: 2000 V
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit breaking current(A): 4500,3 times
Electricity life times AC3: 60*104
Electricity life times AC4: 60*104
Mechanical life times: 300*104
Overload capacity: 8Ie 10S
Remark: “Ie” is Rated current of main circuit.
Aug-17-16
 
1. General
HVJ5 1.14 kv 1000A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1,140V and rated current to 1000A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on.
2. Main technical parameter
Rated voltage: 1140 V
Control voltage: 36 V, 110 V, 220 V, 380 V
Rated current: 1000A
Opening distance: 2±0.2 mm
Over travel: 1±0.2 mm
Final pressure: 30±3 N
Main circuit power frequency voltage withstand: 4200 V
Auxiliary circuit power frequency voltage withstand: 2500 V
Control circuit power frequency voltage withstand: 2000 V
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit breaking current(A): 10000,3 times
Electricity life times AC3: 60*104
Electricity life times AC4: 1.5*104
Mechanical life times: 300*104
Overload capacity: 8Ie 10S
Remark: “Ie” is Rated current of main circuit.
Aug-17-16
 
HVJ20 series vacuum contactor has higher rated current, smaller size and anti-dusty advantages. It can be used in AC50 ~ 60Hz, 2KV power system, rated current to 800A, for long distance making-breaking and frequent starting and controlling of AC motor.
Rated voltage: 2 kv / 2 kv
Rated current: 630A / 800A
Main circuit making ability (A/100 times): 6300 / 6300
Main circuit break-make ability (A/10 times): 5000 / 6000
Maximum breaking ability (A/3 times): 6300 / 6300
Electrical life AC3(times): 600,000 / 600,000
Electrical life AC4(times): 100,000 / 100,000
Mechanical life(times): 1,000,000 / 1,000,000
Rated operating frequency AC3(times /h): 300 / 300
Rated operating frequency AC4(times /h): 120 / 120
Short-time operating frequency times /h(20S): 1200 / 1200
Clearance between open contacts(mm): 3±0.3 / 3±0.3
Over travel(mm): =1 / =1
Aug-17-16
 
HVJ3 7.2KV VACUUM CONTACTOR
1. General
The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 7.2kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear.

2. Working condition:
1) Altitude should not be over 1,000m;
2) Ambient temperature: -5~40°C;
3) Average temperature in 24 hour not exceed 35°C;
4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%;
5) Pollution degree: class 3

Main models and technical parameters
Rated voltage: 7.2 kv
Control voltage: 380/220/110
Rated current: 160A, 250A, 400A, 630A, 800A, 1000A
Clearance: 3.5±0.3 mm
Over travel: 2±0.2 mm
Pressure: >85N
Main circuit power frequency withstand voltage: 32000 v
Auxiliary circuit power frequency withstand voltage: 2500 v
Control circuit power frequency withstand voltage: 2000 v
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit opening current(A): 10Ie
Overload: 8Ie,10 s
Mechanism life: 1 million times
Weight: 25.5 KG
Note: “Ie” represents the rated current of main circuit
Aug-17-16
 
HVJ30 1.14kv vacuum contactor 1000A 1250A
HVJ30-1.14/1000?1250 series AC vacuum contactor is applicable for AC 50HZ power system of rated voltage 1.14KV and rated current up to 1000 A~1250Ato open and close circuit, start and control AC motor frequently. It is suitable for composed magnetic starter with various protective devices (JDB electronic integrated protector, JR9 type over current protection device, resistance-capacitance absorbers). It is particularly suitable for compose a explosion-proof magnetic starter and large mineral switchgear.
Rated voltage: 1.14 kv
Rated current: 1000A 1250A
Making capacity(A): 5000(100 times)
Breaking capacity(A): 4500(10 times)
Limit breaking capacity(A): 5000(3 times)
Electrical life times(AC3): 600,000 times
Electrical life times(AC4): 6,000 times
Mechanical life times: 1,000,000 times
Rated operating frequency (AC3): 600 times /h
Rated operating frequency (AC4): 120 times /h
Short-time operating frequency(20s): 1000 times /h
Contacts separation: 2.8±0.1 mm
Over travel: 1.0±0.1 mm
Aug-17-16
 
JCZR 7.2kv 12kv Indoor Vacuum Contactor-Fuse Combination Electric Appliance

General:
This combination electric appliance may install in the switch cabinet to form the F-C loop, use with the integrated protection device. It is used for loading of the switching on and switching off the power pant as well as the industry and mining enterprise, dropout AC high-tension motor, the transformer, capacitor and so on, and it has overload, short circuit protection function. This combination electric appliance may use in AC 50 HZ three-phase power systems.

Technical Data:
1. Main Technical Parameter see Table 1.
Rated voltage: 7.2 kv / 12 kv
Power frequency withstand voltage phase to phase, to earth: 32 kv / 42 kv
Power frequency withstand voltage the fracture impact withstand voltage(fracture): 60 kv / 75 kv
Fuse rated current A: 25-250 / 25-250
Prospective short circuit breaking current KA: 50 / 50
Prospective short circuit making current(peak value) KA: 130 / 130
Prospective short circuit withstand current( peak value) KA: 10 / 10
Rated short time withstand current( effective value) KA: 4 / 4
Rated short circuit duration S: 4 / 4
Rated making current KA: 4 / 4
Rated breaking current KA: 3.2 / 3.2
Limit breaking current KA: 4.5 / 4.5
Contactor distance between fixed and moving contact mm: 4.5 / 5
Contactor over-travel mm: 1.5 / 1.5
Mechanical life times: Model J:100,000; Model D:300,000 / Model J:100,000; Model D:300,000
Closing coil Rated operation voltage(V): DC220,DC110
Opening coil Rated operation voltage(V): DC220,DC110
Holding coil Rated operation voltage(V): DC220,DC110
Closing coil power: 1200 W
Holding coil power: 15 W
Opening coil power: 80 W
Closing coil Normal work voltage range: 85%-110% rated voltage
Holding coil Normal work voltage range: 85%-110% rated voltage
Opening coil Normal work voltage range: 60%-120% rated voltage
Aug-17-16
 
1. Introduction
JCZ5 7.2 kv vacuum contactor
HVJ6-7.2 series indoor high-voltage AC vacuum contactor has two types: One is Mechanical holding type, the other is Electromagnetic holding type. It is applicable for three-phase AC 50HZ power system of rated voltage 7.2KV and below and rated current up to 630 A to open and close circuit remotely and control electrical equipment like high-voltage motor, transformer and capacitive load. It is especially suitable for fields operated frequently. The contactor uses the international fashionable up and down structure arrangement and has the advantages of small, light, easy to maintain and form a complete set of F-C circuit equipment.
2. Service condition
a) Ambient air temperature: -25?- +40?.
b) Altitude not exceed 2000m
c)Humidity:
-Relative humidity: daily mean not higher than 95?,monthly mean not higher than 90?;
-Aqueous vapor pressure: daily mean not exceed 2.2 KP, monthly mean not exceed 1.8 KP
Ambient air should not be obviously polluted by corrosive or flammable gas or vapor;
C)Free of frequent severe vibration; When running, angle of inclination between installation surface and horizontal plane should not exceed 5?.

Main technical parameters
Rated voltage: 7.2 kv
Control voltage: 110V, 220V
Rated current: 200A, 400A, 630A
Contacts separation: 4.5+1-0.5mm
Over travel: 1.5±0.5 mm
Main circuit power frequency voltage withstand: 32000 V
Auxiliary circuit power frequency withstand voltage: 2500 V
Control circuit power frequency withstand voltage: 2000 V
Making capacity: 10le,100 times
Breaking capacity: 8le, 25 times
Limit breaking current(A): 10le
Mechanical life times: 30×104
Weight: 28KG
Oct-28-23
Supplier From Naif Deira dubai, Dubai, United Arab Emirates
 
TeSys D contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V).

It provides a 220V 50/60Hz AC coil and 1NO+1NC built-in auxiliary contacts.

Multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh)
May-09-19
 
1. General
The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 7.2kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear.

2. Working condition:
1) Altitude should not be over 1,000m;
2) Ambient temperature: -5~40°C;
3) Average temperature in 24 hour not exceed 35°C;
4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%;
5) Pollution degree: class 3

Main models and technical parameters
Rated voltage: 7.2 kv
Control voltage: 380/220/110
Rated current: 630A
Clearance: 3.5±0.3 mm
Over travel: 2±0.2 mm
Pressure: >85N
Main circuit power frequency withstand voltage: 32000 v
Auxiliary circuit power frequency withstand voltage: 2500 v
Control circuit power frequency withstand voltage: 2000 v
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit opening current(A): 10Ie
Overload: 8Ie,10 s
Mechanism life: 1 million times
Weight: 25.5 KG
Note: Ie represents the rated current of main circuit
May-09-19
 
1. General
The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 7.2kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear.

2. Working condition:
1) Altitude should not be over 1,000m;
2) Ambient temperature: -5~40°C;
3) Average temperature in 24 hour not exceed 35°C;
4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%;
5) Pollution degree: class 3

Main models and technical parameters
Rated voltage: 7.2 kv
Control voltage: 380/220/110
Rated current: 630A
Clearance: 3.5±0.3 mm
Over travel: 2±0.2 mm
Pressure: >85N
Main circuit power frequency withstand voltage: 32000 v
Auxiliary circuit power frequency withstand voltage: 2500 v
Control circuit power frequency withstand voltage: 2000 v
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit opening current(A): 10Ie
Overload: 8Ie,10 s
Mechanism life: 1 million times
Weight: 25.5 KG
Note: Ie represents the rated current of main circuit
May-09-19
 
1. General
The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 7.2kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear.

2. Working condition:
1) Altitude should not be over 1,000m;
2) Ambient temperature: -5~40°C;
3) Average temperature in 24 hour not exceed 35°C;
4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%;
5) Pollution degree: class 3

Main models and technical parameters
Rated voltage: 7.2 kv
Control voltage: 380/220/110
Rated current: 160A
Clearance: 3.5±0.3 mm
Over travel: 2±0.2 mm
Pressure: >85N
Main circuit power frequency withstand voltage: 32000 v
Auxiliary circuit power frequency withstand voltage: 2500 v
Control circuit power frequency withstand voltage: 2000 v
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit opening current(A): 10Ie
Overload: 8Ie,10 s
Mechanism life: 1 million times
Weight: 25.5 KG
Note: Ie represents the rated current of main circuit
Feb-19-19

Hvj3 Vacuum Contactor

$413.00
MOQ: Not Specified
 
HVJ3 12KV VACUUM CONTACTOR
Detailed product description:
The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 12kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear.

Working condition:
1) Altitude should not be over 1,000m;
2) Ambient temperature: -5~40°C;
3) Average temperature in 24 hour not exceed 35°C;
4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%;
5) Pollution degree: class 3

.Main models and technical parameters
Rated voltage: 12 KV
Control voltage: 220/110/380
Rated current: 160A, 250A, 400A, 630A
Clearance: 5±0.5 mm
Over travel: 2±0.2 mm
Pressure: >85N
Main circuit power frequency withstand voltage: 42000 v
Auxiliary circuit power frequency withstand voltage: 2500 v
Control circuit power frequency withstand voltage: 2000 v
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit opening current(A): 10Ie
Overload: 8Ie,10 s
Mechanism life: 1 million times
Weight: 30KG
Note: â??Ieâ?? represents the rated current of main circuit

Model Rated voltage(v) Rated current
ï¼?Main circuitï¼?(A) Parameter of main contacts Power frequency
Withstand voltage
V(effective value)
Main
circuit Control
circuit Clearance
(mm) Over travel
(mm) pressure
(N)
Main
circuit Auxiliary
circuit Control
circuit
HVJ3-12/160 12000 220/110/380 160 5±0.5 2±0.2 >85N 42000 2500 2000
HVJ3-12/250 12000 220/110/380 250 5±0.5 2±0.2 >85N 42000 2500 2000
HVJ3-12/400 12000 220/110/380 400 5±0.5 2±0.2 >85N 42000 2500 2000
HVJ3-12/630 12000 220/110/380 630 5±0.5 2±0.2 >85N 42000 2500 2000
 
Model Making capacity Breaking capacity Limit opening current(A) Overload Mechanism life Weight(kg)
HVJ3-12/160 10Ie,100times 8Ie,25times 10Ie 8Ie,10s 1million times 30
HVJ3-12/250 10Ie,100times 8Ie,25times 10Ie 8Ie,10s 1million times 30
HVJ3-12/400 10Ie,100times 8Ie,25times 10Ie 8Ie,10s 1million times 30
HVJ3-12/630 10Ie,100times 8Ie,25times 10Ie 8Ie,10s 1million times 30
Note: â??Ieâ?? represents the rated current of main circuit
Oct-03-18

Vacuum Contactor

$426.00
MOQ: Not Specified
 
1.Introduction
JCZ5 7.2 kv vacuum contactor
HVJ6-7.2 series indoor high-voltage AC vacuum contactor has two types: One is Mechanical holding type, the other is Electromagnetic holding type. It is applicable for three-phase AC 50HZ power system of rated voltage 7.2KV and below and rated current up to 630 A to open and close circuit remotely and control electrical equipment like high-voltage motor, transformer and capacitive load. It is especially suitable for fields operated frequently. The contactor uses the international fashionable up and down structure arrangement and has the advantages of small, light, easy to maintain and form a complete set of F-C circuit equipment.
2. Service condition
a) Ambient air temperature: -25- +40.
b) Altitude not exceed 2000m
c)Humidity:
-Relative humidity: daily mean not higher than 95,monthly mean not higher than 90;
-Aqueous vapor pressure: daily mean not exceed 2.2 KP, monthly mean not exceed 1.8 KP
Ambient air should not be obviously polluted by corrosive or flammable gas or vapor;
C)Free of frequent severe vibration; When running, angle of inclination between installation surface and horizontal plane should not exceed 5.

Main technical parameters
Rated voltage: 7.2 kv
Control voltage: 110V, 220V
Rated current: 200A, 400A, 630A
Contacts separation: 4.5+1-0.5mm
Over travel: 1.5±0.5 mm
Main circuit power frequency voltage withstand: 32000 V
Auxiliary circuit power frequency withstand voltage: 2500 V
Control circuit power frequency withstand voltage: 2000 V
Making capacity: 10le,100 times
Breaking capacity: 8le, 25 times
Limit breaking current(A): 10le
Mechanical life times: 30104
Weight: 28KG
Oct-03-18

Vacuum Contactor

$464.00
MOQ: Not Specified
 
1.Introduction
JCZ5 12kv vacuum contactor
HVJ6-12 series indoor high-voltage AC vacuum contactor has two types: One is Mechanical holding type, the other is Electromagnetic holding type. It is applicable for three-phase AC 50HZ power system of rated voltage 12KV and below and rated current up to 630 A to open and close circuit remotely and control electrical equipment like high-voltage motor, transformer and capacitive load. It is especially suitable for fields operated frequently. The contactor uses the international fashionable up and down structure arrangement and has the advantages of small, light, easy to maintain and form a complete set of circuit equipment.
2. Service condition
a) Ambient air temperature: -25- +40.
b) Altitude not exceed 2000m
c)Humidity:
-Relative humidity: daily mean not higher than 95,monthly mean not higher than 90;
-Aqueous vapor pressure: daily mean not exceed 2.2 KP, monthly mean not exceed 1.8 KP
Ambient air should not be obviously polluted by corrosive or flammable gas or vapor;
C)Free of frequent severe vibration; When running, angle of inclination between installation surface and horizontal plane should not exceed 5.

Main technical parameters
Rated voltage: 12000 v
Control circuit: 110V 220V
Rated current: 200A 400A 630A
Contacts separation: 5+1-0.5 mm
Over travel: 1.5±0.5 mm
Main circuit power frequency withstand voltage: 42000 v
Auxiliary circuit power frequency voltage withstand: 2500 v
Control circuit power frequency voltage withstand: 2000 V
Making capacity: 10le,100 times
Breaking capacity: 8le, 25 times
Limit breaking current(A): 10le
Mechanical life times: 30104
Weight: 32KG
Jul-31-18
Supplier From Yueqing, Zhejiang, China
 
CJX2(LC1-F 3) Magnetic Contactor ac contactor is applicable in the circuit rated voltage up to 1000V AC. 50Hz or 60Hz,rated current up to 780A, for long distance breaking circuit and frequently starting or controlling the motor. It also can be used for the control of distributing circuits of rated current from 200A to 1600A.(AC-1)/115A to 780A(AC-3)
339 Electric Contactors Suppliers
Short on time? Let Electric Contactors sellers contact you.