Main characteristics:
Single-pole NO speed regulation control
With close locking
With forward & reversal rotation device
With speed adjustable knob
Optional output waveform:half wave or full wave.
With dustproof function
Single-speed and double-speed are optional
Mechanical life:more than 1E5 times.
Leader tuning fork level limit switch ld-yc-yg
Free from service
Against high pressure and corrosion
Suitable for both solid and liquid media
No mechanical parts, free from service
PROTOCONTROL offers Signal Isolators to isolate and convert field signals like resistance, current, voltage, frequency to 4-20 mA. These isolators find use in process control industries for signal isolation. Variety of models is available for specific applications.
Transmitters are the field devices which receives signal from field sensors like temperature sensor (Pt 100, thermocouple) or load cell & convert these in suitable form like 4-20mA, O-20 mA, 0-10V as an input for panel instruments.
In the field, many signals are generated such as motor current, armature voltage, position feedback in the form of change in resistance or signals obtained from various types of traducers in standard voltage or current form. These signals are not isolated from input and not suitable for transmission over long distance. Converters are specially developed to overcome these problems in transmission such as line drop, interference, ground looping, and non compatibility to standard processing unit.
Salient features includes complete galvanic isolation between input output and control supply , Independent zero and span adjustments ,Stable current output eliminates need for special cable, shielding,
The isolators are housed in din rail mounting engineering plastic enclosure. Special robust cast Al. enclosures suitable for field mounting are also available.
These Isolators are extensively used in cement, fertiliser, chemical, and processing plants.
Individual packing.
2638 Electric Switches Isolators Suppliers
Short on time? Let Electric Switches Isolators sellers contact you.
1.Endurance with nice elasticity. Its life can be achieved over over 1,000.000 times touch.
2.High abrasive resistance with lubricative
3.Good tightness It can be water, dust and gas resistance so its not easily oxidized.
4.Small volume with good quality.
5.Colorful with surface beautiful.
6.Low cost for electromechanical products.
1.Endurance with nice elasticity Ití»s life can be achieved over over 1,000.000 times touch.
2.High abrasive resistance with lubricative
3.Good tightness It can be water, dust and gas resistance so its not easily oxidized.
4.Small volume with good quality.
5.Colorful with surface beautiful.
6.Low cost for electromechanical products.
1)Compact structure
2 temperature and current sensitive
3)Quick and accurate action
4)CertificationsUL, CUL, VDE, RoHS.
*Compact structure*Simultaneously sensing temperature and current
*Quick and accurate action*Customized service for cables at various specifications is available.
*The riveted terminals can be classified into two types: identical, opposite
* Certifications: UL, CUL, VDE, RoHSProduct specifications:
*Function: single transition: while the temperature reached, it automatically disconnects the power.
*Rated voltage: 22A/125V 10A/250V 20A/16VDCProduct Details: Action temperature difference: ?2? ?3? ?5?
Application temperature range: 50-180? Max.
Current: 22A life
cycle: 10000 Max. Voltage: 125V.
Description
The APL-200 series limit switch box with position indicator provides open to close switch signaling and continuous visible rotational degree monitoring of quarter turn valves. The rugged and compact design is best suited for small ball valve assemblies, or any place where space is limited.
Features
1. Weather proof IP67(NEMA4,4X)
2. Compact and Beautiful Design
Aluminum die-casting housing and powder coated
3. Bolts on Visual Position Indicator,Secure waterproof
4. "Quick-Set" Cam,Spring loaded splined cam
No need to adjust again after initial setting
Easy setting without tool
5. Multipoint terminal strip
Standard 8 points and enough strips for connection
6. Dual cable entries
2X1/2NPT (Standard)
M20X1.5 , PG13.5, PT1/2,PF1/2(Option)
7. Captive cover bolts
No worry to loose bolts while cover opens
8. Easy mounting
NAMUR standard stainless steel shaft and bracket.
Current Rating 5 A max.
Voltage Rating 250 VAC max.
Insulation Resistance 100 Mº+ min.
Dielectric strength AC 1000V for 60 sec.
Operating force 150g max.
Pre Travel 28mm max.
Protection IP 67.
Operating principle : Mechanical diaphragm.
Contact type : Normally open / Normally close.
Input voltage : 12 / 24V DC.
Operating temperature : -30C to +100C.
Connector : 2 Pin connector as per customers requirement.
Mounting : M10 X1 or as per customers requirement.
External load : 1.2W Lamp load.
End fitments : Down stream of Air filter.
MZ series isolation terminals ars applicable to non-explosion proof during the industrial automation and process control, they are used to connect between on-site meters and control rooms, in an attempt to collection, detection, isolation, transmission, distribution and convertion. The applicaion of isolators aim to improve the anti-interference capabilities of automatic control systems of industrial manufacture process, to protect device and enhance the stability and reliability of the systems.
MZ series adopt new modular design, which features super-thin shell, small volume, low power comsumption, high conversion accuracy and anti-interference. They can be combined with other units and DCS, PLC systems etc. In the fields of oil, chemical,power, steel, machinery, metallurgy and light industry.
6.2mm super-thin structure,unified shell dimension.
Modular design,small volume,low power comsumption and high conversion accuracy.
Isolation among input, output and power.
Standard DIN rail mounting.
Stable time: 3~5m.
CE certified.
TM 6000 series is a kind of electrical interface equipment developed by our company which is applicable for non-explosion-proof areas and can be used to connect site instruments and control room.
Through reliable power-input-output isolation, it can resolve the site interference of auto-control system and make sure the stability and reliability of the system. TM 6000 series, including many models selectable, can satisfy the need of signal isolation, distribution, transformation, allocation and alarm driving in the auto-control system.
Our control system can be connected with dimmable led driver and it is controlled by our remote controller with dimming
Brightness function, snap & fade & flash color function, color speed function, 7 colors display for white, red, green, blue, yellow, magenta, cyan. Each current loading for our r, g and b channels can take is 6w, which make the one single channel to 18w ( max 300w ). Please understand that this controller can operates 12v or 24v and we can offer you a complete set of remote controller, receiver and led strips and synchronize for you up to 200w
Applications:
Air and other non-combustible, non-aggressive gases
Monitor overpressure, vacuum and differential pressure for
air and compatible gases
Possible applications are:
monitor air filters and ventilators
monitor air status in heating and cooling circuits
monitor flows in ventilation duct
other applications
Specifications:
Adjustable range: 5 ranges selectable, different engineering
units available, see order information
Pressure limit: 7500Pa
Working temperature limit: -20~ 85ípC
Storage temperature limit: -40~85ípC
Pressure connection: ª+6.0mm plastic pipe, P1 high and
P2 low pressure
Service life: over 106 switching cycles
Electric Contact: SPDT, max 2A/250VAC, max frequency 6
switching cycles/min
Electrical connection: 3 screw terminals
Repeatability: í+2%
Materials: housing PC, cover PC, diaphragm silicone and
contact silver
Weight: 140g with bracket, 90g without bracket
Protection: IP54 with cover
Installation: vertical, pressure ports P1 and P2 downward.
This is the factory-calibrated position. If horizontally
installation needed, the switching value should plus
about 20pa (cover upward) and minus about 10pa (cover
downward). See operation manual.
Accessory: the pressure connection set (part number 1001)
includes plastic pipe 2m, 2 pressure connection parts and 4 screws.
MODELS: 609. X X X Scales for different units
Enclosure With install ear 0
No ear, with bracket 1 mbar inch wc mm wc
Adjustable range 20-300Pa 0 0.2-3 0.08-1.2 2-30
50-500Pa 1 0.5-5 0.2-2 5-50
100-1000Pa 2 1-10 0.4-4 10-100
0.5-2.5KPa 3 5-25 2-10 50-250
Engineering unit Pa 0
mbar 7
inch wc 8
mm wc 9
DEAD BAND INFORMATION: Part No. Range DB
609.X0X 20-300Pa 10Pa
609.X1X 50-500Pa 20Pa
609.X2X 100-1000Pa 20Pa
609.X3X 0.5-2.5KPa 30Pa
609.X4X 1-5KPa 100Pa
2638 Electric Switches Isolators Suppliers