Applications:
Air and other non-combustible, non-aggressive gases
Monitor overpressure, vacuum and differential pressure for
air and compatible gases
Possible applications are:
monitor air filters and ventilators
monitor air status in heating and cooling circuits
monitor flows in ventilation duct
other applications
Specifications:
Adjustable range: 5 ranges selectable, different engineering
units available, see order information
Pressure limit: 7500Pa
Working temperature limit: -20~ 85ípC
Storage temperature limit: -40~85ípC
Pressure connection: ª+6.0mm plastic pipe, P1 high and
P2 low pressure
Service life: over 106 switching cycles
Electric Contact: SPDT, max 2A/250VAC, max frequency 6
switching cycles/min
Electrical connection: 3 screw terminals
Repeatability: í+2%
Materials: housing PC, cover PC, diaphragm silicone and
contact silver
Weight: 140g with bracket, 90g without bracket
Protection: IP54 with cover
Installation: vertical, pressure ports P1 and P2 downward.
This is the factory-calibrated position. If horizontally
installation needed, the switching value should plus
about 20pa (cover upward) and minus about 10pa (cover
downward). See operation manual.
Accessory: the pressure connection set (part number 1001)
includes plastic pipe 2m, 2 pressure connection parts and 4 screws.
MODELS: 609. X X X Scales for different units
Enclosure With install ear 0
No ear, with bracket 1 mbar inch wc mm wc
Adjustable range 20-300Pa 0 0.2-3 0.08-1.2 2-30
50-500Pa 1 0.5-5 0.2-2 5-50
100-1000Pa 2 1-10 0.4-4 10-100
0.5-2.5KPa 3 5-25 2-10 50-250
Engineering unit Pa 0
mbar 7
inch wc 8
mm wc 9
DEAD BAND INFORMATION: Part No. Range DB
609.X0X 20-300Pa 10Pa
609.X1X 50-500Pa 20Pa
609.X2X 100-1000Pa 20Pa
609.X3X 0.5-2.5KPa 30Pa
609.X4X 1-5KPa 100Pa
Differential pressure switch 15RB-EE2 for power system Main: hydraulic machinery and components, hydroelectric generating units; coal-fired generating units; generating units; electrical and electronic products processing; mechanical parts processing. Mainly engaged in the power industry host (steam turbine, water machine, boiler, turbine) accessories, spare parts, spare parts, auxiliary equipment and environmental protection equipment. supply power plant, steel accessories are as follows: Need more products for power plant now if you don't know where to search a product. BFP filter HX-10*30Q Oil-water alarm OWK-2 separation filter QYLX-63*10Q2 gate DWG.19D8591 hydraulic return filter CFRX-100*20Q hydraulic suction filter assembly ZL366X-A63*10 HTD SERIES OF VALVE POSITION TRANSDUCER LVDT TDZ-1-H 0-50 Eccentric Module DF2042 Probe TD-1-50 bulk oil filters LY-48-25W Auxiliary Contacts LXW22-11MB casing wearing 326*340*38 three screw pump HSNSQ3440-46 high pressure switch RC771BZ090H Keo lam kin GDZ 421 Room Temp Solid Epoxy Cement Generator SWG-2 filter replacements NLX-40*1 EH oil cooler CY300B.0 hydraulic filter unit TZX-E63*20 EH oil sealing ring 23*3.5 oil feeder filter GP300*20Q2 chemical filter cartridge XUI-A160*100S hydraulic filter life TFBX-45*80 Hydraulic Filter FRD.WJA1.058 Steering engine filter HX-160*40 TRANSDUCER S3(T)-WD-3S-515A4BN filter pressure hydraulic LY 38/10W 25 hydraulic return oil filter 10H02C07V replaceable filter drier core CFF2X-520*100 300MW turbine DC Emergency pump coupling driving pin 125LY-23-4 hydraulic oil filter pump with cart Q2U-E400*30FS Hydraulic filter element STXX-40*40 Differential pressure switch 15RB-EE2 transformer oil filter machine WU-H25*180S bearing vibration sensor SDY 3800 XL 11 MM electric transfer oil pump 125LY-23 oil filter parts WU-400*200 LVDT FOR IP Governing Valves LVDT TDZ-1-H 0-300 Hydraulic Filter PQX-50*5Q3 Steam Turbine Generator Sealing Grease T2075 MSV\CV\RCV actuator working filter ZTJ300-00-07 hydraulic filter price TZX-E100*5Q3 manifold block for OPC solenoid valve HQ16.17Z Seal Set for BLADDER nxq 2-L 63/31.5-h inlet filter HX.BH-160*20W oil filter elements HC9100FCP8Z stainless steel bellows globe valve WJ80F1.6P Oil cooler Duplex filter GY93.63X*10 Drain valve 1-1/2"B07-8076Z-02TS hydraulic filter price list NX-400*30 Differential pressure switch 15RB-EE2 DFYL-2022-8-9-ZJ
Supplier: Pressure switches, differential pressure switches, pressure difference switches, atex/baseefa certified flameproof pressure switches.
Flow switch Specifications Efs series flow switch is an automatic element of protecting and controlling flow in the line of the system; Medium: water, ethylene glycol and other liquid which is not classified as hazardous; Liquid temperature:+5~-+120f¦; Max. Working pressure: 1.0mpa; The rate of the flow can be adjustable and it is stable. Eflow switch can not be used where the liquid in the pipes will drop below the liquid's freezing point.
Supplier: Combustible gas leak detector, toxic gas leak detector, liquid level controller, differential pressure switch, differential pressure transmitter, damper actuators
Services: Commissioning services, calibration services
Buyer: Pid controllers, electronic components
Applications: The Series C2 gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment. Feartures: Wide choices of 56 ranges available to suit your needs Simple, frictionless movement, it quickly indicates low air or non-corrosive gas pressures-either positive, negative or differential The design resists shock, vibration and over-pressures No any fluid to evaporate, freeze or cause toxic and leveling problems It's inexpensive High accuracy-guaranteed within 2.5% of full scale Specifications Specifications: Service: Air and non-combustible compatible gases. (Natural Gas option available.) Housing: Die cast aluminum case and bezel, with acrylic cover, exterior finish is coated gray Accuracy: í+2.5% of full scale Pressure Limits: -70 to 100 KPa Size: 4" diameter dial face Temperature Limits: 20 to 140ípF (-6.67 to 60ípC) Mounting Orientation: Diaphragm in vertical position Connections: 1⁄8" NPT(F) high and low pressure taps, duplicated-one pair side and one pair back Weight: 500g Standard accessories: 1 m connecting tube, two 1⁄8" NPT plugs for duplicate pressure taps, two1⁄8" pipe thread to rubber tubing adapters and three flush mounting adapters with 3 screws Mounting and Options: They can be flush or surface mounted and pressure connected with standard hardware supplied With the optional A-610 Pipe Mounting Kit they may be conveniently installed on horizontal or vertical 11⁄4" -2" pipe Adjustable signal flag Integral with plastic gage cover. Available for most ranges except those with medium or high pressure construction. Can be ordered with gage or separate MODELS: Mode Range Fluid Used C1-3 0-3in.w.c. Red Oil C1-80 0-80mm w.c. Red Oil C1-700PA 10-0-700PA Red Oil
Applications: C1008 is a low cost, state-of-the-art, maintenance-free infrared carbon dioxide transmitter in the climate zone or in the ventilation duct. It can help you to decrease your energy consumption while maintaining a healthier indoor climate. Features: Using SenseAir´s patented NDIR technology and offers reliable measurements Two analogue & one relay contact outputs Maintenance-free in normal applications Non-frill design; cost-optimized for connection to DDC/PLC Two different housing options: 1) IP20 wall mount (w or w/o LED bar display) 2) IP65 duct mount (without display) Operating Temperature Range : 0 - 50ípC Storage Temperature Range: -40 to +70ípC Specifications: Operating Humidity Range: 0 to 95% RH (non-condensing) Warm-up Time: í_ 1 min. (@ full specs í_ 15 minutes) Sensor Life Expectancy: > 15 years Maintenance Interval: no maintenance required Power Input: 24 VAC/VDC Power Consumption: < 1 W Sensing method : Gold-plated infrared (NDIR) wave-guide technology with Automatic Background Calibration (ABC) and passive gas diffusion Measurement range: 0-2000 ppm CO2 Repeatability: í+ 20 ppm í+ 1 % of reading Accuracy: í+ 30 ppm í+ 2 % of reading Annual Zero Drift : < í+ 10 ppm Pressure Dependence: + 1.6 % reading per hPa OUT 1: 0 -10 VDC for 0 - 2 000 ppm OUT 2: 4 ¿C 20mA for 0 - 2000 ppm Options OUT 3: N.C. & N.O.: contacts pre-set at 1000ppm Housing and Dimension: WALL MOUNT (standard) Dimension: 100 x 80 x 27 mm (H x W x D) Protection class: IP20 60 mm hole separation for European standard J-boxes. DUCT MOUNT (model ¿CK) Dimension: 142 x 84 x 46 mm (H x W x D) Duct probe length: 245 mm (adjustable according to duct dimension) Protection class: IP65 MODELS: Model Descriptions VC1008T Basic sensor/transmitter without display, wall mount,IP20 housing VC1008T-Ks Basic sensor/transmitter without display, duct mount,IP65 housing Options -R Relay contact:24V,1A voltage free,Relay setpoint:1000ppm -NTC NTC temperature sensor -PTXX PT100 or PT1000 temperature sensor Other ranges 0.6%,2%,4%
Applications: H2,3,4 humidity and temperature transmitters are designed for environment monitoring and controlling in industrial, commercial and other buildings. These transmitters can be used for: Humidity and temperature monitoring of supply, exhaust and return air(H2, duct mount) Humidity and temperature monitering in critical environment such as outside air(H3, outside mount) Other applications of immersion humidity and temperature monitoring(H4, separate probe) Features: High performance digital sensors and circuits, ensure accurate measurement and temperature compensation Good long term stability and reliability 100% field changeable sensors, no re-calibration needed Fast response Multiple output signals selectable Industrial design, SS probe and sintered filter High protection rate to IP65 Specifications: Relative Humidity: Sensor: Capacitance polymer Range: 0~100%RH Output: 4~20mA /0~10VDC/RS485 Accuracy: 2%,3%RH(25ípC,20~80%RH) Hysteresis:
Supplier: Differential pressure gauges, differential pressure switches, pressure line filters with filter clog indicators float switches, pressure switches
Buyer: Row materials, reed switches
Supplier: HVAC instruments, differential pressure switch, humidity and temperature sensor, transmitter