Introduction Standard Meter test offers test of internal standard power &automatic calibration. Clamp inputs and direct inputs are at usersí» option when it comes to external input. Possess two functions of Faults Recorder and Faults Replay. And the two functions mentioned above can serve field technicians to analyze the faults concerned. Possess Remote Diagnosis which allows users to monitor the output state of meters by Internet from remote places. The running state of the machine can be identified by error comparison of sample values against data output of remote data acquisition instrument. Capable of testing all types of voltage relays, current relays, frequency relays, power relays, impedance relays, harmonics relays, differential relays and synchronism Check relays by manual or by automation. Fault Simulation calibrates nominal values of distance protection device and zero-sequence protection device. And fault simulations also lead to distance relay test of distance protection device and zero-sequence protection device. And K2066 can auto-scan the ratio braking curve of differential protection in microcomputer and digital transformer as well as Generator-transformer Group. And K2066 possesses GPS Synchronizer. The installation of particular heating radiator contributes to the safety of K2066 There are four high-power ventilating fans inside the Host. Thermal-shutdown is adopted to ensure the excellent stability & reliability of the amplifier even under long-playing working state along with high current. Current generator provides the function of open-circuit protection and open-circuit alert in itself. While Voltage generator possesses the functions of short-circuit protection, of output testing against waveform distortion, of Auto-recognition & Auto-alarming & Self-lock protection against wrong wiring as well as the function of Dynamic Waveform Monitor& Display. Possess isolated output contacts, and the same case for idle contacts and electric potential contacts; and well adapt to various wiring installation. Possess 7-channels voltage output; That one optional channel can works as auxiliary power supply by setting software shall make it easier for site-commissioning. Possess well-structured offline running function, the Host has independent output of 7 voltages & 6 currents of which amplitude, phase and frequency are continuously adjustable at usersí» option. And large LCD screen 640*480 is installed and its interface display is legible in English version. Internal design is architectural style framework and high intensity aluminum alloy box of which vibration & shock resistance enables the equipment subject to strict vibration. With the application of the latest DSP and large-scale programmable components FPGA from TI Company in United States as well as 1448-dot waveform simulation, K2066 possesses better Transient Response and better Amplitude-frequency Characteristic. Besides, at present KINGSIN stands as the exclusive manufacturer in China who initiates the application of 20-digit serial port DA to further improve the output precision. Weight:24 KG Dimensions 420ú¿Dú¬í-140 (W)í-360 (H) mm
Introductionú¦ 1. Advanced SCM control system enables K3030 system to run steadily. 2. Simple internal design also contributes to steady system running 3. 1448 points waveform fitting is for every cycle, reaching the leading position at home, as has significantly improved the amplitude-frequency Characteristic and voltage-current transient/instantaneous response for the system, with the current transient response of 20 ª¦s. And the transient voltage response of 30 ª¦s, obviously exceeds the China national standard (200 ª¦s). Excellent transient response can be more suitable for the development trend of the new rapid digital type protection relay. 4. 20-digit serial D/A Converter is adopted, and the serial D/A Converter has better linearity and precision than the parallel D/A, greatly increasing the precision of voltage and current signal. 5. 40-220V/0.6A auxiliary DC power supply is under control of software, the power supply can individually provide working power to the protection device or other equipments. Ripple coefficient is less than 0.1% and accuracy is 0.5% Remarkú¦ 1.During the test, amplitude value, phase and frequency are continuously and arbitrarily adjustable with simple operation. Be able to test various types of AC/DC voltage relay, AC/DC current relay, frequency relay, power relay, impedance relay, harmonic relay, differential relay and synchronism relay about operate time and operate value by manual or by machine;Faults-Simulation enables users to calibrate fixed values of distance protection device and zero-sequence protection device. And fault simulations also lead to distance relay test of distance protection device and zero-sequence protection device. And K3066 can auto-scan the ratio restraint curve of differential protection in microcomputer and digital transformer as well as Generator-transformer Set. 2.The installation of particular heating radiator contributes to the reliable practicability of K3030.There are four high-power ventilating fans inside the Host. Thermal-shutdown is adopted to ensure the excellent stability & reliability of the amplifier even under long-playing working state along with high current. Current generator provides the function of open-circuit protection and open-circuit alert in itself. While Voltage generator possesses the functions of short-circuit protection, of output testing against waveform distortion, of Auto-recognition & Auto-alarming & Self-lock protection against misconnecting as well as the function of Dynamic Waveform Monitor&Display.. 3.Possess isolated input contacts, and the same case for idle contacts and electric potential contacts; and well adapt to various wiring installation. 4.Four voltage output channel, of which one channel is set as auxiliary DC supply by software, making it more convenient for field debugging. 5.Internal design is of architectural style framework and of shock & impact resistance external box made of high intensity aluminum alloy enables the equipment subject to rigid vibration 6.Be able to work as DC generator to provide Relay Protection Device with DC Voltage Generator(0í¡220V) 7.Direct edition on test report when using PC, and that scanning graph can be added into test report is useful for report analysis. Weight:24KG Dimensions:420ú¿Dú¬í-140 (W)í-360 (H) mm
Hour meter This hour meter is mechanical type.Widely applied in each kind of machine, equipment and device(such as environmental protection equipment generator etc). Used for to demonstrate the machine, the equipment, the device accumulation operating time. It is mechanical type accumulation, the longest time for accumulation time can be 11 years. It still can maintain the data after the power cut. Itemno. Bz142-1 bz142-2 bz142-3 Operating voltage ac 24-450v ac 24-450v dc 10-80v Ferquency 50hz 60hz Time range 0-99, 999.99h Dimension 48 x 48 x 40mm Net weight 50g Mounting insert type
Description: Contact rating:3a, 3c Contact material:sliver alloy Contact capacity:10a 220vac/28vdc Nominal coil power: 1.4w, 2.5va 385*190*300mm n.W:14kg
JR28(LR2-D) series thermal relay is suitable for using in the main circuits rated voltage up to 660V,rated current 93 A, AC 50Hz or 60Hz,for over-voltage protection of AC motor. The relay has the differential mechanism and temperature compensation and can plug in CJX2(LC1-D) series AC contactor, also be independently fixed. Specifications: LR2-D13, D23,D33
JRS1(LR1-D) series thermal relay is suitable for using in the circuits rated voltage up to 600V,rated current 93A.AC 50Hz or 60Hz for over-voltage protection of AC motorú«The relay has the differential mechanism and temperature compensation and can plug in CJX2(LC1-D) series AC contactor, also be independtly fixedú« Specification: LR1-D09, D40,D63,D80 Rated voltage: 220, 380, 415, 440, 660V Rated current: 0. 1~0. 16, 0. 16~0. 25, 0. 25~0. 40, 0. 40~0. 63, 0. 63~1, 1~1. 6, 1. 6~2. 5, 2. 5~4, 4~6, 5. 5~8, 7~10, 10~13, 13~18, 18~25, 23~32, 30~40, 38~50, 48~57, 57~66, 63~80A
JRS2(3UA) series thermal overload relay are suitable for overload and phase-failure protection of AC motors with frequency of 50/60Hz,voltage up to 690-1000v,current up to 0.1-400A under 8-hours duty or uninterrupted duty. Several functions provided by these relays are: phase-failure protection, temperature compensation, ON/OFF indication and manual/automatic reset. The relays can be mounted onto contactors or installed as single units.
Relays Miniature, contact load capacity up to 30a, 40a Terminal types as inserting Coil voltage:6, 12, 24 Contact arrangement:1a, 1b, 1c, 2a, 1u Outline size:29x29x25.6mm Weight:36g
Rated voltage:12v Pins:6 The pins and fixator made of cooper. Packing by buyers needing
Relay Electromagnetic relay: jqx-7ma, jqx-7mb, jqx-008m, jqx-030m, jqx-030mc, jqx-030md, jqx-117m, jqx-128m, jqx-132m, jqx-136m, jqx-136md, jqx-142m, jqx-142ma, jqx-164m, jqx-168m, jqxh-167m, jrc-4m, jrc-5m, jrc-10m, jrc-071m, jrc-089m, jrc-123m, jrc-129m, jrc-131m, jrc-152m, jrc-154m, jrw-3m, jrw-114m, jzc-064m, jzc-064ma, jzc-078m, jzc-084m, jzc-090m, jzc-097m, jzc-098m, jzc-102m, jzc-102ma, jzc-130m, jzc-134m, jzc-158m, jzx-012m, jzx-127m, jzx-127ma, jzc-145m, kjrc-071m, kjrc-105m, kjzc-064ma, kjzc-078m, Thermostat relay :juc-1m, juc-068m, juc-1m-jx, juc-027m, juc-027ma, juw-149m, juc-079f, juc-079fa, juc-079ft, juc-054m, juc-083m, juc-083ma, juc-121f, juc-162f, juc-066m Time relay : jsb-184m Rfcoaxialrelays:, jpt-161m Sealedelectromagnetic relay :jmc-022m, jmc-069m, jmc-099m, jmc-099ma, jmc-104m, jmc-135m, jmc-153m, jmc-157 Special relay: bk15-1 , gk-2, gk-1, gk-3, gk-5, gk-6, jf-1,
Time relay can be widely used in machines and equipment needing self-control of high precision and reliability. It is characteristic of small size, light weight, compact structure, high dependable and efficient,long life,etc.
Thermal relays (1)lr1, lr2 series thermal relay It is suitable for using in the circuits rated voltage up to 660v, rated current 93a ac 50hz or 60hz, for over-voltage protection of ac motor. (2)jrs2 (3ua) series thermal relay It is suitable for using in the circuits rated voltage up to 600-1000v and current up to 630a. Leave factory packing
Field Failure Relay (FFR) For D.C. Drives and Instrumentation The Field Failure Relay, when used in series with the field circuit, ensures that no power is supplied to the Armature unless Field circuit is complete. Field Failure Relay, also known as Field Loss Relay protects the D.C. Shunt motor or main circuit under open field conditions. Welcome to Insel Rectifiers: Your Premier Destination for Field Failure Relays At Insel Rectifiers, we take immense pride in being recognized as the forefront manufacturer and supplier of Field Failure Relays. Our commitment revolves around providing cutting-edge solutions that guarantee the reliability and efficiency of your systems. With a trusted legacy in the industry, we excel in the art of meticulously crafting precision-engineered Field Failure Relays and Field Loss Relays. Our dedication sets the benchmark for quality and innovation, ensuring your systems operate seamlessly and meet the highest standards of performance. Precision in Field Failure Relay Manufacturing At Insel Rectifiers, we take pride in our meticulous approach to manufacturing Field Failure Relays. These relays play a critical role in safeguarding your systems against unforeseen failures, and our commitment to precision engineering ensures that each relay meets the highest industry standards. As a distinguished Field Failure Relay manufacturer, we understand the importance of reliability in your operations. Efficient Solutions for Field Loss Relays Insel Rectifiers is your go-to source for efficient Field Loss Relay solutions. Our relay products are designed to detect and respond to field failures promptly, minimizing downtime and ensuring the seamless operation of your systems. As your dedicated Field Loss Relay supplier, we prioritize innovation to deliver cutting-edge solutions tailored to meet the unique needs of your applications. Innovative Technology, Trusted Supplier Insel Rectifiers is not just a manufacturer; we are your trusted partner in reliable relay solutions. Our commitment to innovation is reflected in the advanced technology embedded in our Field Failure Relays. As a leading Field Loss Relay supplier, we understand the importance of providing products that not only meet but exceed customer expectations. Why Choose Insel Rectifiers? Quality Assurance: Rigorous testing procedures ensure the reliability and durability of our Field Failure Relays. Innovation: We continually invest in research and development to bring you the latest advancements in relay technology. Customer Satisfaction: At Insel Rectifiers, your satisfaction is our priority. Our dedicated support team is ready to assist you with any inquiries or technical assistance.
4 channel power distribution for H51X, H51q for extension rack F-BASE RACK 11 inclusive miniature fuse 5x20, 4 A-T, H
Product Introduction JWJXC-H125/0.44 stepless enhanced contact slow release relay is an important component in interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and Close and so on. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage JW.JXC-H125/0.44. The stepless strengthened contact slow release relay is used as a general relay in the signal circuit. Applicable environment a) Ambient temperature: -40~+60;
Product Usage The JWJXC-7200 type stepless enhanced contact relay is used as a power supply supervisory relay for the electric point machine in the power supply screen of a large station. Product function JWJXC-7200 type stepless enhanced contact relay is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. product structure The electromagnetic system of the stepless strengthened contact relay is a stepless magnetic circuit with an enlarged size. The contact system is composed of two parts: a normal contact and a strong contact. The normal contact is the same as the stepless relay. Switches, switch start, etc.) designed contacts and isolator. Mechanical properties Number of contact groups: 4QJ; 2H Identification pin number: 14, 55; Strengthen the contact gap: not less than 7mm; Ordinary contact gap: not less than 4.5mm; Reinforce the gap of the support plate: generally not less than 0.35mm; Reinforce the gap of the support: the reinforcement is not less than 0.1-0.3mm;
Product Usage The JWJXC2-6800 type enhanced contact relay is used in the distributed power supply screen. Product function It is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60 b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. test method Standard test conditions Temperature: +15â??~+45â??; Relative humidity: 45%~75% Air pressure: 86kPa~106kPa Requirements for testing measuring tools, meters, and power supply The accuracy of the measuring tool for measuring appearance and installation dimensions should not be less than 0.05mm; the accuracy of the feeler gauge should not be less than level 2; the measurement error of the force measurement should not be greater than 2%. The accuracy of the DC voltmeter and ammeter used for testing should not be less than 0.5, and the accuracy of the AC (50Hz) voltmeter and ammeter should not be less than 1. The power supply voltage should remain stable, and its fluctuation range should not exceed 5%. The DC power supply should be a DC generator, battery or AC full-wave rectifier power supply (except for special regulations, the ripple factor should not be greater than 5%). The waveform of the AC power supply should be a sine wave with a frequency of 50 Hz. Mechanical properties
Product Usage The JYJXC-135/220 type has a pole reinforced contact relay used as a switch control relay in a signal circuit. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Mechanical properties Number of contact groups: 2DF, 2DFJ; Identification pin number: 15, 54; Contact gap: ordinary contact is not less than 4.5mm; reinforced contact is not less than 7mm; Pallet gap: ordinary contact point is not less than 0.35mm; Ordinary contact pressure: the positioning contact is not less than 150mN; the reverse contact is not less than 150mN; Strengthen the contact pressure: the positioning contact is not less than 400mN; the reverse contact is not less than 400mN; Contact uniformity error: between ordinary contacts and ordinary contacts, between ordinary contacts and reinforced contacts, no more than 0.2mm, between reinforced contacts and reinforced contacts, no more than 0.1mm. Positioning or reverse position holding force is not less than 4N;
product description JWXC-7 type infinite relay is a relay widely used in railway signal technology, called signal relay, and it is an important part of railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JWXC-7 type infinite relay is used as a general purpose and air-proof step-down relay in the signal circuit. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. product structure Infinite relay is the typical structure of AX series relay, which is composed of electromagnetic system and contact system. The electromagnetic system includes coils, iron cores, vehicle irons and armatures. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the yoke by a butterfly-shaped steel wire, which is flexible in movement. There is a heavy hammer in the transmission part of the Yantie to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, vehicle iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence.
Product Introduction The JWJXC-160 type stepless enhanced contact relay is an important element in the interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the switch and the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JWJXC-160 type stepless strengthened contact relay is used as a phase-failure supervision relay in the power supply screen. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.