PREPARATIONS
The substrate, bolt and anchor holes must be clean, sound, dry and free of oil, grease,
without laitance and loose particles.
Prewet the bolt holes thoroughly, but no standing water in it. Before applying ITLS CA-007H absorbent substrates must be saturated thoroughly, but without standing water.
MIXING
Mix 3.2-4.4 liters of clean water with 25kg bag of ITLS CA-007H together. To add water
based on the condition of stirring and keep stirring around 5 minutes until grouting well.
APPLICATIONS
Pour ITLS CA-007H mortar after mixing into the reserved cavities and recesses use the
stick or bar to remove the air bubble, ensure that air entrapped into the grout is allowed to
escape. Suggest to blend the grout by auto-mixer for better application.
COVERAGE
25 Kg ITLS CA-007H when mixed with water will produce approx. 13.5 liters of Liquid
Grouting Mortar.
ITLS CA-007H suggest to be placed in thickness ranging from 10-15cm/layer.
Specifications 1.odorless 2.low VOC 3.antimicrobial 4. mildew resistant 5.environmentally friendly 6.waterproof 7.Scrub resistance Description It is an enhanced mildew proof product adopting nano-scale Ag+ antimicrobial and mildew proof technology, integrating odorless formula, with fresh product smell, smooth paint film, durable and beautiful paint.As an affordable and environmentally friendly product with excellent decorative performance, it is characterized by fresh smell, environmental health, strong covering power, large painting area, convenient constructionapplication, short constructionapplication period, etc. Specification Data Solvent: Water Pigment: Non-lead pigment Theoretical Solids By Volume: more than 50% Theoretical Coverage: Theoretically 1 litre of this product covers 12 sqm in 1 coat Coverage varies considerably depending on application methods and surface roughness and porosity. Shelf Life: Minimum 12 months at 77F(25C) unopened and store in cool and dry places. Recommended Film Thickness: Wet: 80 micron Dry: 30 micron Dry Time: At 77F (25C) and 50% R.H. to recoat Touch Dry: 1 hours Recoat : 2-3 hours Application: Brush, Roll, conventional spray or Airless Spray. Thinner: Thin up 15% depend on different application methods & temperature. Do not over thin by adding more than 30% water. Brush or Roller: For sealing new or bare surfaces thin with up to 1 part of clean water to 5-10 parts of paint(10%-20%) Conventional Spray: Add up to 1 part clean water to 5 parts paint(20%) Airless spray: do not thin Clean-up: Clean up equipment with water Typical painting system Substrate System All kinds of Wall surfaces 1.Alkali Resistance Primer (1 coat) 2.Emulsion Wall Paint (2 coats)
Supplier: Rice, corn, sugar, wheat, cement, aluminum ingots, copper scrap , used rail and hms 1&2, urea, sulphur, cooking oils, petroleum products, aviation fuel, mazut, millet, alfalfa grass, timber logs, teak wood, wood pallet
Buyer: Steel scrap, used rails, cement
Supplier: Cotton yarn, cotton and poly cotton fabrics, recycled yarn , grs certified , shoddy , wool waste , bed sheets, towels, kitchen towels, knitted bed sheets , jersey sheets, woven bedding, spinning waste, rice, sugar, cement, clinker, frozen chicken, frozen beef, edible oils, palm oil, wheat, soybean, corn, barley, bitumen, copper cathode, urea, aluminum ingot, sulfur, coal, ores, dap, pet coke, fertilizers, npk, base oil, petroleum products , mattress cover , pillow , micro fibre bed sheets , quilt , pink salt , himalayan salt
Services: Sourcing
Supplier: Refractory bricks, high alumina bricks, acid proof bricks, tiles and castables, all mortars and fire clay, low cement castables, insulating castables, conventional dense refractory bricks, insulation bricks, cold face, hot face insulation bricks, hot face insulation bricks, acid resistant bricks/components, membranes, acid resistant cement, construction chemicals, class 1 ar tiles and bricks 38mm and 75mm, 4457 vitrified ar tiles with 0% water absorption, 20mm & 25m, primer, mastics, pot. silicate cement, coerce cement, furnace based cement, crushed refractory boiler bed material, acid resistant tiles, acid resistant brick fireclay type, acid resistant brick red shale type, bitumen primer, epoxy resin & hardner, furan powder and syrup solution,
Supplier: Agricultural products (coffee, rice, black pepper, cocoa, cashew nuts, etc.) garment/ medical product (non woven coveralls, gowns, medical facemask, arm cover, cap, shoes cover, bra, felt suit, towel, labor protection product) plastic products, pe tarpaulin, pvc tarpaulin, jumbo bag, pp bag, rubber products
Supplier: 1121 parboiled rice, 1121 white and sella rice, or ir64 white and parboiled rice, all types of basmati and non basmati rice, corn (maize), corn flour, brown cumin, black cumin, cardamom, dry red chili, chili powder, raw sulphur, hulled white sesame seed,, poppy seed, all types and sizes floor ceramic tiles in all size, all type wall tiles in all size, all types of front elevation tiles, all type of marble & granite, all type of poly pvc door window frame, all type waterproof door, all type bathroom door, all types of sanitary ware like a washbasin, toilet seat urinal seet and other all sanitary ware. door frame (poly pvc), d6 diesel, dap fertilizer, urea fertilizer, bitumen, en590 10ppm diesel, jet a1 fuel, chicken paw, chicken feet , other chicken part, whole chicken, any grade steem coal and charcoal, d2 gas oil, liquefied natural gas, liquefied petroleum, mazut m100, aviation kerosene colonial grade 54 and all type date , dates
Buyer: Dry fruits, spices, areca nuts, palm oil, areca, betelnut, clove, cardamom, black cardamom, bay leaves, cinnamon, almond, pistachio, cashew nuts, date, dry dates, refined soya oil, refined premium sunflower oil
Acid / Alkali Resistant Tiles/Bricks * Our Acid proof tiles, Acid alkali resistant tiles, Chemical resistant tiles are fully vitrified tiles which are manufactured using special non ferrous clay, processed at extremely high temperatures this process causes the raw materials to fuse and form a compact mass with an extremely low water absorption of less than 0.5% resulting in the formation of a very strong body with a flexural strength of 38 N/mm2, solid through color fade proof with a very hard surface Mohs hardness of 7. * The acid resistant tiles come in a range of sizes and thicknesses from ranging from 8-25mm. Our acid proof tiles meet stringent specification norms of IS 4457:2007 and relevant ASTM/DIN standards which ensure excellent performance in Acid/Alkali/Chemical (expect Hydrofluoric acid and its derivatives). Corrosion Protection Applications * Factory Floors subject to corrosion from Chemicals, Acids, Oil & Solvents * Pickling tank and surrounding areas * Food & Beverage Industry flooring * Battery rooms and Control rooms * Demineralization plants * Walls of washing and Paint shop areas * Acid Resistant Tiles Manufacturers India * Our acid proof tiles provide excellent abrasion resistance, anti-skid properties for worker safety and high aesthetic appeal. We also provide specialized corner tiles for reducing chances for acid attack through construction joints. Our standard sizes are 200x100, 200x200 & 300x300 millimeters.
* PHOSCAST Phoscast : Phosphate Bonded Castables * PURPOSE customers using FBC boilers (Particularly underbed feed FBC boilers) for the protection of inbed coils against erosion potential by applying highly abrasive resistant refractory on inbed coils above fuel feed system. BACKGROUND * Two of such actions are providing special alloy studs on inbed coils and applying highly abrasive resistant refractory on the outer bottom loops of inbed Coils which are above the fuel feed nozzles. * GANESHAS has taken number of approaches to identify the key factors affecting erosion rates with an objective to enhance the life of inbed tubes as well as implementing the corrective action to reduce the erosion rates. Phosphate coatings are often used to protect steel parts against rusting and other types of corrosion * Erosion of inbed coils in fluid bed combustor is unavoidable phenomenon however the rate of metal wastage and thus the life of tubes depends on various factors like ash & fuel properties, design of Combustor / feeding system, flue gas velocities operating conditions etc. It has been also observed that maximum erosion prone inbed coils are those which come above fuel feed nozzles and an area of approximately 1 to 1.5 mts around fuel feed systems are badly affected. APPLICATION Phoscast-90 XR can be applied by ramming with wooden mallet having adequately large head @" dia x 5" length x 10â?? Jong handle). The desired lining or repair thickness is built up in several courses while ramming the mass to uniform thickness. Phoscast refractory should never be trawled to obtain smooth surface; ramming only should finish surface. Any excess mass is to be sliced off with trowel edge and then finished by ramming again for bed coil. Tube application of AFBC boiler, the material pasty mass should be finger pressed into the studs of the tube with maximum force. Finish should be given by pressing the hand palm against material applied, using surgical type thin rubber hand gloves.
APPLICATION OF SK-HB K-SILICATE MORTAR : * K-SILICATE is used for jointing Acid Resisting brick in construction of vessels in suited for construction of fume chambers and stacks handling hot, dry Acid fumes and vapors. It is also used for jointing chemical resisting stoneware pipes. K-SILICATE cement is good bedding material for Acid â?? Resisting bricks and tiles. The concrete surface needed protection should be dryed, clean and rough. The bricks or tiles will be set with K-SILICATE cement over concrete surface applied with a suitable an impermeable interliner. When Bedding and Jointing Materials are the same. On the treated surface bricks or tiles are bedded to a thickness of about 6 mm and tamp gently with a wooden piece till the paste squeezes out of joints. The paste that is squeezed out of the joint should be removed by trowel with good finishing. After the mortar of the joint is dryed treat the joints with 20% Hydrochloric Acid Solution by means of brush. A.R.lining should be always in contact with Acid and not with water. Concrete subtract like Floor, Wall, tanks and similar surface should be protected with a membrane of Bitrok Mastic or compound steel tanks should be protected with rubber or PVC subjected to chemical conditions and temperature of chemical media. The Brick lining is recommended over the protective layer of Bitrok Mastic. When Bedding and Jointing Materials are Different. Spread the silicate type mortar about 6 to 8 mm thick on the back of the tile or brick. Press the tile on the bed leaving required space for joints between tiles for bricks. After the bedding mortar is set, fill Mp the joints with specified cement.PRODUCT DATA SHEET FOR SK-HB ( K-SILICATE) MORTAR A general purpose cement for acid conditions Resistant to High & medium concentrations of most of the common organic and inorganic acids except Hydroflouric acid. Recommended where the concentration of the acid is high suitable for high temperature. Unsuited to aqueous solutions, alkaline conditions. PREPARATIONS OF MORTAR : * Measure 1 part by weight of K-SILICATE solution into a suitable mixing pan. * Add slowly and gradually 3 parts by weight K-SILICATE mortar and mix thoroughly to form a smooth mortar. * In hot season very large batches of mortar will become stiff quite rapidly therefore small batches, not exceeding 4 to 8 kgs. Will be prepared. * The cement mortar will be used before it starts setting.