3SP_O3_5 P
15x15 O3 Sensor 5 ppm Pinned Package 110-406
3SP_O3_5 P Ozone Sensor O3 Sensor Description
SPEC's printed sensors offer the performance of the best quality electrochemical sensors at a fraction of the price. SPEC's printed sensors are also ultra-thin, offering easy integration into wireless, portable, and networked solutions. These sensors are ideal for health, environmental, industrial and residential monitoring, because of their high performance, low cost and small size.
3SP_O3_5 P Ozone Sensor O3 Sensor Benefits
* Small Size with Low Profile (20x20x3 mm)
* Long Life (10 years expected life)
* Fast Response (< 15 seconds)
* Low Power Consumption
* Individually Calibrated (NIST Traceable)
* ROHS Compliant
* Improved stability and ppb performance
3SP_O3_5 P Ozone Sensor O3 Sensor Applications
* Air Quality Monitoring
* Industrial Safety
* Air Purification Control
3SP_O3_5 P Ozone Sensor O3 Sensor Specifications
* Measurement Range: 0 to 5 ppm
* Lower Detection Limit: < 20 ppb
* Resolution: < 20 ppb
* Response Time: < 15 seconds typical
* Sensitivity @ 5ppm: -60 +/- 10 nA/ppm
* Operating Temperature: -30 to 50'C
* Operating Humidity: 0 to 100% RH non-condensin
* Power Consumption: 10 to 50 uW
Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2 Features & Benefits: User-friendly operation, Easy-to-read display for multiple languages, Lightweight convenience, Ease of maintenance, Serviceability, The new 1-Series sensor for enhanced reliability, Connected Bluetooth Low Energy (BLE) capabilities.
o3 gas sensor is widely used in water disinfection, food processing and purification, food storage and preservation, medical and health, and household disinfection and purification. In ozone applications, a certain concentration of ozone is an important parameter to ensure disinfection, energy conservation and pollution prevention. But as If the concentration of ozone in the environment is too high, it will cause harm to the human body. Therefore, it is very necessary to effectively monitor the concentration of ozone. The transmitter uses electrochemical technology to measure O3 concentration, and the reaction is quick and sensitive, which can reliably detect ozone concentration. degree. o3 gas sensor product uses 485 communication, standard ModBus-RTU communication protocol, communication address and baud rate can be set, the farthest pass The letter distance is 2000 meters. The equipment is 10-30V wide-voltage power supply, and the enclosure has a high degree of protection, which can adapt to various harsh conditions on site.
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
ULPSM-O3 968-005 Ultra-Low Power Analog O3 Sensor Module DESCRIPTION Quickly integrate Ozone sensing into your system with very low power consumption and a simple analog sensor signal output. The ULPSM converts the Ozone sensor??s linear current signal output to a linear voltage signal, while maintaining the sensor at its ideal biased operation settings. ULPSM-O3 968-005 Ultra-Low Power Analog O3 Sensor Module BENEFITS * 0 to 3 V Analog Signal Output * Low Power Consumption < 45 uW * Fast Response * On-board Temperature Sensor * Easy Sensor Replacement * Standard 8-pin connector ULPSM-O3 968-005 Ultra-Low Power Analog O3 Sensor Module APPLICATIONS * Fixed Industrial Safety Monitoring * Portable Industrial Safety Monitoring * Portable Personal Safety Monitor * Indoor Air Quality Monitoring * Outdoor Air Quality Monitoring * Air Purification Control ULPSM-O3 968-005 Ultra-Low Power Analog O3 Sensor Module PERFORMANCE CHARACTERISTICS * Measurement Range: 0 to 20 ppm * Lower Detection Limit: 0.3 ppm * Resolution: 0.15 ppm * Accuracy: < ± 2 % of reading * Response Time T90: < 30 seconds * Power-On Stabilization Time: 60 minutes recommended
Photocells Fans & ventilation, Hazardous area lighting Industrial plugs & sockets Industrial & commercial Lamps Light fittings: fluorescent, weatherproof & floodlighting Refrigeration & air conditioning spares Water heating elements Wiring accessories MCB's Circuit breaker Vacuum Breakers Control transformers Fuses & load break devices Hazardous area products Industrial beacons Industrial sounders, buzzers Industrial surge protection Safety switches Clamp meters Multi-meters Testers Semiconductors: thyristors, rectifiers Pressure switches Solenoid & pilot valves Photoelectric Sensors
Supplier: 1) plastic injection molded parts
2) mould design and development
3) automotive plastic parts
4) auto electrical parts
5) industrial/automotive battery parts
6) plastic household products
7) gear moulding
8) over moulding
9) insert moulding
Buyer: 1) copper plated/tin plated terminals for auto electrical parts.
Product Overview The ignition point of a fire inside the electric panel is mostly the part where the terminal block is fastened, so in order for initial fire extinguishing, the solution should be closely installed to the part where the terminal block is fastened. In the case of a small electric panel, a complete initial fire extinguishing is expected for fires occurring inside the electric panel by attaching the SFEX Pad to the top surface of the electric panel. Product Feature It has an excellent performance in the initial fire suppression as it can be installed near the ignition point as a flexible rope type. It uses a stand-alone method based on polymer chemistry so that it does not cause malfunctions and maintenance costs. The thermo-responsive Granule composed of KNO3 and subsidiary catalysts It does not affect the peripherals after the fire goes out. Function of SFEX Granule = fire extinguishing agent storage tank + temperature sensor + nozzle function Fire extinguishing method : Suffocation + subsidiary catalyst Example of Installation 1 : SFEX Line - If ducts exist Installing the SFEX Line horizontally or vertically in the ducts closest to the expected ignition points It can be installed without damaging the panel Example of Installation 2 : SFEX Line - If ducts do not exist Installing the SFEX Line horizontally or vertically, close to the expected ignition points of the Electric panel Example of Installation 2 : SFEX Pad - Small Electric Panel Simply attach it to the top inside the Electric panel.
PE coil pipes and tubes for water and wire cable conduit PL231 The PE coil pipes and tubes can be used: water pipe 4 â?? 6 â?? 1-inch black coil with pressure 1.6mpa, OD 20-75mm, WT 2.3-6.8mm pe conduit cable embedded wire cable and optical cable, OD 20-200mm, WT 1.8-3.5mm weak current protection tube and communication tube, OD 20-200mm, WT 1.8-3.5mm We use new 100% pure raw PE material WHY NEW MATERIAL HDPE PIPES? 1. Health performance PE pipe processing without adding heavy metal salt stabilizer, no scaling layer, and no bacteria. 2. Corrosion resistance It can resist various chemical media erosion, with no electrochemical corrosion. 3. Service life Under rated temperature and pressure conditions, PE pipes can be used for more than 50 years. 4. Impact resistance PE pipe toughness, high impact strength, heavy objects directly pressed through the pipeline will not break. 5. Connection performance The strength of the hot melt or electric melt interface of the polyethylene HDPE pipe is higher than that of the pipe body, and the joint will not be broken due to soil movement or live load. 6. Construction performance It has a lightweight pipe weight, a simple welding process, convenient construction, and a low overall project cost.
CAT-5- UTP STP FTP SFTP