HVJ3 12KV VACUUM CONTACTOR
Detailed product description:
The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 12kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear.
Working condition:
1) Altitude should not be over 1,000m;
2) Ambient temperature: -5~40°C;
3) Average temperature in 24 hour not exceed 35°C;
4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%;
5) Pollution degree: class 3
.Main models and technical parameters
Rated voltage: 12 KV
Control voltage: 220/110/380
Rated current: 160A, 250A, 400A, 630A
Clearance: 5±0.5 mm
Over travel: 2±0.2 mm
Pressure: >85N
Main circuit power frequency withstand voltage: 42000 v
Auxiliary circuit power frequency withstand voltage: 2500 v
Control circuit power frequency withstand voltage: 2000 v
Making capacity: 10Ie,100 times
Breaking capacity: 8Ie,25 times
Limit opening current(A): 10Ie
Overload: 8Ie,10 s
Mechanism life: 1 million times
Weight: 30KG
Note: â??Ieâ?? represents the rated current of main circuit
1. General The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 7.2kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear. 2. Working condition: 1) Altitude should not be over 1,000m; 2) Ambient temperature: -5~40°C; 3) Average temperature in 24 hour not exceed 35°C; 4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%; 5) Pollution degree: class 3 Main models and technical parameters Rated voltage: 7.2 kv Control voltage: 380/220/110 Rated current: 630A Clearance: 3.5±0.3 mm Over travel: 2±0.2 mm Pressure: >85N Main circuit power frequency withstand voltage: 32000 v Auxiliary circuit power frequency withstand voltage: 2500 v Control circuit power frequency withstand voltage: 2000 v Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit opening current(A): 10Ie Overload: 8Ie,10 s Mechanism life: 1 million times Weight: 25.5 KG Note: Ie represents the rated current of main circuit
HVJ3 12KV VACUUM CONTACTOR Detailed product description: The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 12kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear. Working condition: 1) Altitude should not be over 1,000m; 2) Ambient temperature: -5~40°C; 3) Average temperature in 24 hour not exceed 35°C; 4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%; 5) Pollution degree: class 3 .Main models and technical parameters Rated voltage: 12 KV Control voltage: 220/110/380 Rated current: 160A, 250A, 400A, 630A Clearance: 5±0.5 mm Over travel: 2±0.2 mm Pressure: >85N Main circuit power frequency withstand voltage: 42000 v Auxiliary circuit power frequency withstand voltage: 2500 v Control circuit power frequency withstand voltage: 2000 v Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit opening current(A): 10Ie Overload: 8Ie,10 s Mechanism life: 1 million times Weight: 30KG Note: “Ie” represents the rated current of main circuit
HVJ3 12KV VACUUM CONTACTOR Detailed product description: The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 12kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear. Working condition: 1) Altitude should not be over 1,000m; 2) Ambient temperature: -5~40°C; 3) Average temperature in 24 hour not exceed 35°C; 4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%; 5) Pollution degree: class 3 .Main models and technical parameters Rated voltage: 12 KV Control voltage: 220/110/380 Rated current: 160A, 250A, 400A, 630A Clearance: 5±0.5 mm Over travel: 2±0.2 mm Pressure: >85N Main circuit power frequency withstand voltage: 42000 v Auxiliary circuit power frequency withstand voltage: 2500 v Control circuit power frequency withstand voltage: 2000 v Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit opening current(A): 10Ie Overload: 8Ie,10 s Mechanism life: 1 million times Weight: 30KG Note: â??Ieâ?? represents the rated current of main circuit Model Rated voltage(v) Rated current ï¼?Main circuitï¼?(A) Parameter of main contacts Power frequency Withstand voltage V(effective value) Main circuit Control circuit Clearance (mm) Over travel (mm) pressure (N) Main circuit Auxiliary circuit Control circuit HVJ3-12/160 12000 220/110/380 160 5±0.5 2±0.2 >85N 42000 2500 2000 HVJ3-12/250 12000 220/110/380 250 5±0.5 2±0.2 >85N 42000 2500 2000 HVJ3-12/400 12000 220/110/380 400 5±0.5 2±0.2 >85N 42000 2500 2000 HVJ3-12/630 12000 220/110/380 630 5±0.5 2±0.2 >85N 42000 2500 2000  Model Making capacity Breaking capacity Limit opening current(A) Overload Mechanism life Weight(kg) HVJ3-12/160 10Ie,100times 8Ie,25times 10Ie 8Ie,10s 1million times 30 HVJ3-12/250 10Ie,100times 8Ie,25times 10Ie 8Ie,10s 1million times 30 HVJ3-12/400 10Ie,100times 8Ie,25times 10Ie 8Ie,10s 1million times 30 HVJ3-12/630 10Ie,100times 8Ie,25times 10Ie 8Ie,10s 1million times 30 Note: â??Ieâ?? represents the rated current of main circuit
Supplier: Led bulb, tube light, panel light, decoration light, wall light, steel wires, steel plate, stainless steel plate, twisted wire rods, galvanized wires, wire mesh, site fencing, mosquito mesh, thread rods, rebar, twisted rods, t bar, nuts and bolts, hardware, pvc pipes, upvc pipes, api pipes, melamine, mdf board, plywood, film faced, shuttering, packing, core veneer, face veneer, hdf molded door skin, door filler, tubular particle boards, pvc boards, wpc boards, doors, block board, hard board, gypsum board, canopy, carpet, flooring wooden, bamboo, laminated engineering, tiles, granite tiles, granite blocks, black galaxy, wash basin, water closets, washbasins, ss sinks, faucets, furniture, pvc edge bending, crew, locks, pvc seals, silicone cartridges, shower enclosures, shower door hinges, handles, knobs, brackets, slides, nails, solar panels, flexible solar panels, solar power station, battery, inverters, rechargeable fans, lights, spring, 3ply disposable face mask, oxygen concentrator ,
Services: Buying office, oem, components sourcing, value added services
Buyer: In shell pecan nut, macadamia nut
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. • 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb • Wattage: 10W • Blue UV light • Lumen: 900-1000lm • Color Temperature (CCT): 6500K • Input Voltage: AC 90-130V & 220v-240V • With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
1. General The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 7.2kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear. 2. Working condition: 1) Altitude should not be over 1,000m; 2) Ambient temperature: -5~40°C; 3) Average temperature in 24 hour not exceed 35°C; 4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%; 5) Pollution degree: class 3 Main models and technical parameters Rated voltage: 7.2 kv Control voltage: 380/220/110 Rated current: 630A Clearance: 3.5±0.3 mm Over travel: 2±0.2 mm Pressure: >85N Main circuit power frequency withstand voltage: 32000 v Auxiliary circuit power frequency withstand voltage: 2500 v Control circuit power frequency withstand voltage: 2000 v Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit opening current(A): 10Ie Overload: 8Ie,10 s Mechanism life: 1 million times Weight: 25.5 KG Note: Ie represents the rated current of main circuit
1. General The vacuum contactor is mainly used in the power system with AC 50Hz and rated voltage 7.2kV, for making or breaking circuit and to make electromagnetic starter with suitable protective device and F-C switchgear. 2. Working condition: 1) Altitude should not be over 1,000m; 2) Ambient temperature: -5~40°C; 3) Average temperature in 24 hour not exceed 35°C; 4) When the highest temperature is 40°C, the relative humidity should not be higher than 50%; 5) Pollution degree: class 3 Main models and technical parameters Rated voltage: 7.2 kv Control voltage: 380/220/110 Rated current: 160A Clearance: 3.5±0.3 mm Over travel: 2±0.2 mm Pressure: >85N Main circuit power frequency withstand voltage: 32000 v Auxiliary circuit power frequency withstand voltage: 2500 v Control circuit power frequency withstand voltage: 2000 v Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit opening current(A): 10Ie Overload: 8Ie,10 s Mechanism life: 1 million times Weight: 25.5 KG Note: Ie represents the rated current of main circuit
JCZR 7.2kv 12kv Indoor Vacuum Contactor-Fuse Combination Electric Appliance General: This combination electric appliance may install in the switch cabinet to form the F-C loop, use with the integrated protection device. It is used for loading of the switching on and switching off the power pant as well as the industry and mining enterprise, dropout AC high-tension motor, the transformer, capacitor and so on, and it has overload, short circuit protection function. This combination electric appliance may use in AC 50 HZ three-phase power systems. Technical Data: 1. Main Technical Parameter see Table 1. Rated voltage: 7.2 kv / 12 kv Power frequency withstand voltage phase to phase, to earth: 32 kv / 42 kv Power frequency withstand voltage the fracture impact withstand voltage(fracture): 60 kv / 75 kv Fuse rated current A: 25-250 / 25-250 Prospective short circuit breaking current KA: 50 / 50 Prospective short circuit making current(peak value) KA: 130 / 130 Prospective short circuit withstand current( peak value) KA: 10 / 10 Rated short time withstand current( effective value) KA: 4 / 4 Rated short circuit duration S: 4 / 4 Rated making current KA: 4 / 4 Rated breaking current KA: 3.2 / 3.2 Limit breaking current KA: 4.5 / 4.5 Contactor distance between fixed and moving contact mm: 4.5 / 5 Contactor over-travel mm: 1.5 / 1.5 Mechanical life times: Model J:100,000; Model D:300,000 / Model J:100,000; Model D:300,000 Closing coil Rated operation voltage(V): DC220,DC110 Opening coil Rated operation voltage(V): DC220,DC110 Holding coil Rated operation voltage(V): DC220,DC110 Closing coil power: 1200 W Holding coil power: 15 W Opening coil power: 80 W Closing coil Normal work voltage range: 85%-110% rated voltage Holding coil Normal work voltage range: 85%-110% rated voltage Opening coil Normal work voltage range: 60%-120% rated voltage