Fnad Electrical Appliance Plant, established is located in Ningbo, China. It is 2km away from Geely Automobile Industrial Park. It is a science and technology enterprise integrating with R&D, manufacture, trade and service. The Plant has focused on motor protection for more than years. It is specialized in applications of single-chip microcomputer technology in the fields of industrial control, power electronics and automobile electronics.
Our main products include motor protectors, phase failure protectors, phase sequence protectors, volt-ammeters, surge protector, temperature controllers, etc. we have an in-depth study in prevention of occurrence of phase failure, phase sequence, overload, under-load, overvoltage, under-voltage, three-phase imbalance, over-current and similar abnormalities in customersâ?? equipments and provide such solutions as prevention, alarming and equipment protection. It supports major elevator plants, thermal power plants, automobile plants, crane factories, textile mills, refrigerating plants and chemical plants and provides solutions for them. Some products have passed CE certification and ROSH environmental certification of European Union.
We endeavor to make the company to be listed in Hong Kong in 2020. Welcome to visit and communicate with us.
-
Product Details 3.1 Key Specifications/Special Features Function Rated input voltage * Relay output Model Phase sequence and phase loss monitoring 3-phase, 3-wire 220 to 440 VAC Relay: 1 NC,1 NO TVR-2000B 3-phase, 3-wire 380 to 660 VAC Relay: 1 NC,1 NO TVR-2000C * The power supply voltage is the same as the rated input voltage. Ratings Rated input voltage 3-phase, 200 to 440 VAC (3-wire) Input load Approx. 2.6 VA Operating time Phase sequence 1 s±0.05 s Phase loss 0.1 s max. (when the voltage changes rapidly from 100% to 0% of rated voltage) Indicators LED Normal: Green light; phase loss: Red light; Inverted: Yellow light Output form Relay Output: SPDT contact Output relay ratings Rated load Resistive load 5 A at 250 VAC 5 A at 30 VDC Maximum switching capacity: 1,250 VA, 150 W Minimum load: 5 VDC, 10 mA (reference values) Mechanical life: 10 million operations min. Electrical life: 5 A at 250 VAC or 30 VDC:50,000 operations 3 A at 250 VAC/30 VDC:100,000 operations Ambient operating temperature -20 to 60°C (with no condensation or icing) Storage temperature -25 to 65°C (with no condensation or icing) Ambient operating humidity 25% to 85% RH (with no condensation) Storage humidity 25% to 85% RH (with no condensation) Altitude 2,000 m max. Applicable wires Stranded wires, solid wires, or ferrules Applicable wire size 0.25 to 1.5 mm2 (AWG24 to AWG16) Wire insertion force 8 N max. for AWG20 wire Screwdriver insertion force 15 N max. Wire stripping length 8 mm Ferrule length 8 mm Current capacity 10 A (per pole) Number of insertions 50 times Weight Approx.55g Mounting Mounts to DIN Track, or screw mounting Dimensions 30 Ã? 60 Ã?70 mm (WÃ?DÃ?H) Specifications Input frequency range 50 to 60 Hz Phase loss detection level 80%±10% of rated input Calculation Formula = 1 â?? ((Highest phase-to-phase voltage â?? Lowest phase-to-phase voltage)/ Average three-phase phase-to-phase voltage) Applicable standards Conforming standards EN 60947-5-1 Installation environment (pollution level 2, Overvoltage category III) EMC EN 60947-5-1 Insulation resistance 20 MΩ min. Between external terminals and case Between input terminals and output terminals Dielectric strength 2,000 VAC for one minute Between external terminals and case Between input terminals and output terminals Impulse withstand voltage 6 kV (between live terminals and exposed, non-charged metal parts) Vibration resistance Frequency: 10 to 55 Hz, 0.35-mm single amplitude 10 sweeps of 5 min each in X,Y, and Z directions Shock resistance 100 m/s2, 3 times each in 6 directions along 3 axes Degree of protection Terminals: IP20 -
Fnad Electrical Appliance Plant, established is located in Ningbo, China. It is 2km away from Geely Automobile Industrial Park. It is a science and technology enterprise integrating with R&D, manufacture, trade and service. The Plant has focused on motor protection for more than years. It is specialized in applications of single-chip microcomputer technology in the fields of industrial control, power electronics and automobile electronics. Our main products include motor protectors, phase failure protectors, phase sequence protectors, volt-ammeters, surge protector, temperature controllers, etc. we have an in-depth study in prevention of occurrence of phase failure, phase sequence, overload, under-load, overvoltage, under-voltage, three-phase imbalance, over-current and similar abnormalities in customersâ?? equipments and provide such solutions as prevention, alarming and equipment protection. It supports major elevator plants, thermal power plants, automobile plants, crane factories, textile mills, refrigerating plants and chemical plants and provides solutions for them. Some products have passed CE certification and ROSH environmental certification of European Union. We endeavor to make the company to be listed in Hong Kong in 2020. Welcome to visit and communicate with us. -
Key Specifications/Special Features Ratings Power supply voltage Power consumption 24 VAC/DC: 1.8 VA/1 W max. 100 to 240 VAC: 2.5 VA max. Rated insulation voltage 600 VAC Operating value setting range (SV) 10% to 100% of maximum setting range Operating value 100% operation at set value Reset value setting range (HYS) 5% to 50% of operating value Reset method Note:Manual reset: Turn OFF power supply for 1 s or longer. Operating time setting range (T) 3to8 s Indicators Normal : Green light; Overvoltage Undervoltage : Yellow light Output form one Normally open and one normally closed Output relay ratings Rated load 5 A at 250 VAC (Resistive load) 5 A at 30 VDC (Resistive load) 1 A at 250 VAC (Inductive load) 0.2 A at 48 VDC (Inductive load) Minimum load: 5 VDC, 10 mA (reference values) Mechanical life: 10 million operations min. Electrical life: 5 A at 250 VAC or 30 VDC: 50,000 operations 3 A at 250 VAC or 30 VDC: 100,000 operations Ambient operating temperature -20 to 60°C (with no condensation or icing) Storage temperature -25 to 65°C (with no condensation or icing) Ambient operating humidity 25% to 85% RH (with no condensation) Storage humidity 25% to 85% RH (with no condensation) Altitude 2,000 m max. Applicable wires Stranded wires, solid wires, or ferrules Applicable wire size 0.25 to 1.5 mm2(AWG24 to AWG16) Wire insertion force 8 N max. for AWG20 wire Screwdriver insertion force 15 N max. Wire stripping length 8 mm Ferrule length 8 mm Current capacity 10 A (per pole) Weight Approx. 60 g Mounting Mounts to DIN Track Dimensions 30 � 60 �76 mm (W�H�D) Specifications Conforming standards EN 60947-5-1 Installation environment (pollution level 2, Overvoltage category III) Insulation resistance 20 MΩmin. Between external terminals and case Between power supply terminals and input terminals Between power supply terminals and output terminals Between input terminals and output terminals Dielectric strength 2,000 VAC for one minute Between external terminals and case Between power supply terminals and input terminals Between power supply terminals and output terminals Between input terminals and output terminals Impulse withstand voltage 6 kV (between live terminals and exposed, non-charged metal parts) Vibration resistance Frequency: 10 to 55 Hz, 0.35-mm single amplitude 10 sweeps of 5 min each in X,Y, and Z directions Shock resistance 100 m/s2, 3 times each in 6 directions along 3 axes Degree of protection Terminals: IP20 -
Supplier: Japanese quality switchgear components, breakers, magnetic contactors, switches, pilot lights, pushbuttons, panel instrumentations, power management meter, protection relays, transformers, inverters, ups.
Supplier: Industrial electrical wires and cables, ups systems and ancillary, junction boxes, mccb, relays and various other electrical products and equipment.
Services: We believe in quality, cost effectiveness and timely service. we try to understand and do the best as per the client requirements.
Buyer: Industrial electrical parts
Features High performance Embedded-Industrial-Computer. 8.4¡ high-resolution large LCD screen. Display all kinds of test data, operating states, and prompts and help messages. Windows operating system, Slim industrial Keyboard and optical Mouse, and many Hotkeys, most convenient to operate. Perform all test items without any external device, automatically display and record test data, and automatically plot vector diagrams and characteristic curves, and print reports. Provide many automatic test procedures. GPS synchronously trigger, synchronization error less than 50|¨¬S. USB port to transmit data and maintenance operating software. High performance D/A converter, assure high waveform accuracy and excellent linearity, transient response and frequency-amplitude characteristic. Particular waveform generation algorithm, assure pure sine wave. Hi-Fi power amplifier, create high output power and low ripple. Except of traditional Ua, Ub, Uc, Ia, Ib, Ic, the fourth voltage Ux can be applied to many functions, such as 3Uo and synchronous voltage, etc. Eight switch input and Four pairs of idle contact output. Switch input ports are compatible with idle contact and active contact, and capable to identify the polarity of active contact, and work well during ¡¨¤250V. Self-diagnosis and multi-protection, reasonable heat dissipation structure, ensure safety and reliability. Well-designed, high-strength aluminium alloy case with carrying handle, facilitate moving to test on site.
Model t200a (250aac, 500vac, ac/dc current) can be used to test many types of relays, including high burden relay and ct. Operation is easy, no much training is required. High power current source for high burden relay test Capable of testing differential relay with two independent current sources Capable of testing directional relay with adjustable phase angle In-built ammeter and voltmteter 120s output time at 250a Rotating mouse control and quick control buttons Large lcd display Many ready test modules for automatic test applications (secondary injection test set, relay tester, single phase relay test set, universal tester)
Model s40a (3*40a, 3*150v) has large lcd display and panel control facilities. No external pc is required. It can easily test many types of relays, including distance relay, df/dt relay. The rotating mouse and quick touch buttons make the operation very easy. 3*40a, 3*150v Additional 200ma ac current source Aux dc (24v, 110v, 220v) 4 binary inputs, 1 binary output Locally with color lcd (universal relay tester, relay test equipment, 3 phase relay test set, secondary injection test system)
Supplier: Labels, carton boxes, books, metalized printing, printed materials, electronic components, parts, panels, note book printing, text book printing, cake box,groundnut oil
Buyer: ,