SH-300-DS NDIR Carbon Dioxide Sensor Module Features
* Best Extremely Precise Sensor
* Quick Response Time
* Long Time Use, Stable performance at High & Low Temperature
* Waterproof Filter for anti static filters fine dust and humidity in the air
* One-way air indraft for represent average value when momentary CO2 Value change in the air
* Low Current consumption
* Output support: UART, 0~3V Analog
SH-300-DS NDIR Carbon Dioxide Sensor Module Application
* CO2 Control for Indoor Air Quality
* CO2 Measuring for Ventilation Control
* CO2 Control for Building, Hospital, School
* CO2 Control for Air cleaner, Air conditioner.
* Mushroom Control, Boiler Control
SH-300-DS NDIR Carbon Dioxide Sensor ModuleTechnical Specification
* Measuring Type: Dual Light Wavelength NDIR
* Measuring Range: 0~3,000/5,000/50,000/100,000 ppm
* Accuracy: ±2% FS, ±3% measured value @ 0 ~ 50'C
* Response Time: Every 2.0 Seconds
* Warm-Up Time @25'C: < 90sec
* Output support: UART, 0~3V Analog
* Operating Temperature: -10 ~ 50'C
* Operating Humidity: 0 ~ 99.5% RH (Non Condensing)
SH-300-DS NDIR Carbon Dioxide Sensor Module Features * Best Extremely Precise Sensor * Quick Response Time * Long Time Use, Stable performance at High & Low Temperature * Waterproof Filter for anti static filters fine dust and humidity in the air * One-way air indraft for represent average value when momentary CO2 Value change in the air * Low Current consumption * Output support: UART, 0~3V Analog SH-300-DS NDIR Carbon Dioxide Sensor Module Application * CO2 Control for Indoor Air Quality * CO2 Measuring for Ventilation Control * CO2 Control for Building, Hospital, School * CO2 Control for Air cleaner, Air conditioner. * Mushroom Control, Boiler Control SH-300-DS NDIR Carbon Dioxide Sensor ModuleTechnical Specification * Measuring Type: Dual Light Wavelength NDIR * Measuring Range: 0~3,000/5,000/50,000/100,000 ppm * Accuracy: ±2% FS, ±3% measured value @ 0 ~ 50'C * Response Time: Every 2.0 Seconds * Warm-Up Time @25'C: < 90sec * Output support: UART, 0~3V Analog * Operating Temperature: -10 ~ 50'C * Operating Humidity: 0 ~ 99.5% RH (Non Condensing)
SH-300-NDC NDIR CO2 Sensor Module Features * Best Extremely Precise Sensor * Quick Response Time * Long Time Use, Stable performance at High & Low Temperature * Waterproof Filter for anti static filters fine dust and humidity in the air * One-way air indraft for represent average value when momentary CO2 Value change in the air * Low Current consumption * Output support: UART, 0~3V Analog SH-300-NDC NDIR CO2 Sensor Module Application * CO2 Control for Indoor Air Quality * CO2 Measuring for Ventilation Control * CO2 Control for Building, Hospital, School * CO2 Control for Air cleaner, Air conditioner. * Mushroom Control, Boiler Control SH-300-NDC NDIR CO2 Sensor Module Technical Specification * Measuring Type: Dual Light Wavelength NDIR * Measuring Range: 0 ~ 3,000 / 5,000 / 10,000 ppm * Accuracy: ±2% FS, ±3 % measured value @0 ~ 50'C * Response Time: Every 2.0 Seconds * Warm-Up Time @ 25'C: < 90sec * Output support: UART, 0~3V Analog * Operating Temperature: -10 ~ 50'C * Operating Humidity: 0 ~ 99.5% RH (Non-Condensing)
SH-300-NDTH NDIR Carbon Dioxide Sensor Module Features * Best Extremely Precise Sensor * Quick Response Time * Long Time Use, Stable performance at High & Low Temperature * Waterproof Filter for anti static filters fine dust and humidity in the air * One-way air indraft for represent average value when momentary CO2 Value change in the air * Low Current consumption * Output support: UART, 0~3V Analog SH-300-NDTH NDIR Carbon Dioxide Sensor Module Application * CO2 Control for IAQ * Building, Hospital, School * Air cleaner, Air conditioner * Mushroom control, Boiler control SH-300-NDTH NDIR Carbon Dioxide Sensor Module Technical Specification * Measuring Type: Non-Dispersive Infrared (NDIR) * Measuring Range: 0 ~ 3,000 / 5,000 / 10,000 ppm * Accuracy: FS ±2%, measured value±3% @ 0 ~ 50'C * Response Time: Every 2.0 Seconds * Warm-Up Time @25'C: < 90sec * Output support: UART, 0~3V Analog * Operating Temperature: 0 ~ 50'C * Operating Humidity: 0 ~ 95%RH (Non Condensing)
SH-300-NDC NDIR CO2 Sensor Module Features * Best Extremely Precise Sensor * Quick Response Time * Long Time Use, Stable performance at High & Low Temperature * Waterproof Filter for anti static filters fine dust and humidity in the air * One-way air indraft for represent average value when momentary CO2 Value change in the air * Low Current consumption * Output support: UART, 0~3V Analog SH-300-NDC NDIR CO2 Sensor Module Application * CO2 Control for Indoor Air Quality * CO2 Measuring for Ventilation Control * CO2 Control for Building, Hospital, School * CO2 Control for Air cleaner, Air conditioner. * Mushroom Control, Boiler Control SH-300-NDC NDIR CO2 Sensor Module Technical Specification * Measuring Type: Dual Light Wavelength NDIR * Measuring Range: 0 ~ 3,000 / 5,000 / 10,000 ppm * Accuracy: ±2% FS, ±3 % measured value @ 0 ~ 50'C * Response Time: Every 2.0 Seconds * Warm-Up Time @25'C: < 90sec * Output support: UART, 0~3V Analog * Operating Temperature: -10 ~ 50'C * Operating Humidity: 0 ~ 99.5% RH (Non-Condensing)
Ready stock of Edge 82-133 / 300 pcs per box Origin : Malaysia Moq 1,000,000 boxes, first trial order 100,000 boxes 20000 boxes per container Fob : Manila
Ginger root Botanical name: Zingiber officinale Linn. Family: Zingiberaceae. Ginger oil and oleoresins are the volatile oil derived by steam distillation of ginger and oleoresin. It is obtained by percolating the powdered rhizomes of Ginger, Zingiber officinale with volatile solvents. Ginger contains 1-2 percent of volatile oil, 5-8 percent of pungent acrid oleoresin and starch. Zingiberene is the chief constituent in the oil of ginger. Oil is employed for flavoring all kinds of food products and confectionary and finds limited use in perfumery. Oleoresin, commercially called Gingerin contains pungent principles viz. gingerol and shogaol apart from the volatile oil of ginger and is used as an aromatic, carminative, stomachic and as a stimulant. Oleoresin from ginger is obtained conventionally by extraction of dried powdered ginger with organic solvents like ethyl acetate, ethanol or acetone. Commercial dried ginger yields 3.5-10.0 per cent oleoresin. Ginger oleoresin is a dark brown viscous liquid responsible for the flavour and pungency of the spice. Ginger of commerce or `Adrak` is the dried underground stem or rhizome of the plant, which constitutes one of the five most important major spices of India, standing third or fourth, competing with chillies, depending upon fluctuations in world market prices, world market demand and supply position. Ginger, like cinnamon, clove and pepper, is one of the most important and oldest spices. It consists of the prepared and sun dried rhizomes known in trade as `hands` and `races` which are either with the outer brownish cortical layers (coated or unscraped), or with outer peel or coating partially or completely removed. Ginger requires a warm and humid climate. It is cultivated from sea level to an altitude of 1500 meters, either under heavy rainfall conditions of 150 to 300 cm or under irrigation. The crop can thrive well in sandy or clayey loam or lateritic soils. The composition of dry ginger is given below: Dry Ginger rootMoisture:6.9 % Protein:8.6 % Fat:6.4 % Fiber:5.9 % Carbohydrates:66.5 % Ash:5.7 % Calcium:0.1 % Phosphorous:.15 % Iron:0.011 % Sodium:0.03 % Potassium:1.4 % Vitamin A:175 I.U./100 g Vitamin B1:0.05 mg/100 g Vitamin B2:0.13 mg/100 g Niacin:1.9 mg/100 g Vitamin C:12.0 mg/100 g Calorific value:380 calories/100 g. Ginger Oleoresin is obtained by extraction of powdered dried ginger with suitable solvents like alcohol, acetone etc. Unlike volatile oil, it contains both the volatile oil and the non-volatile pungent principles for which ginger is so highly esteemed. Concentration of the acetone extract under vacuum and on complete removal of even traces of the solvent used, yields the so called oleoresin of ginger. Ginger oleoresin is manufactured on a commercial scale in India and abroad and is in great demand by the various food industries.