SH-300-DS NDIR Carbon Dioxide Sensor Module Features
* Best Extremely Precise Sensor
* Quick Response Time
* Long Time Use, Stable performance at High & Low Temperature
* Waterproof Filter for anti static filters fine dust and humidity in the air
* One-way air indraft for represent average value when momentary CO2 Value change in the air
* Low Current consumption
* Output support: UART, 0~3V Analog
SH-300-DS NDIR Carbon Dioxide Sensor Module Application
* CO2 Control for Indoor Air Quality
* CO2 Measuring for Ventilation Control
* CO2 Control for Building, Hospital, School
* CO2 Control for Air cleaner, Air conditioner.
* Mushroom Control, Boiler Control
SH-300-DS NDIR Carbon Dioxide Sensor ModuleTechnical Specification
* Measuring Type: Dual Light Wavelength NDIR
* Measuring Range: 0~3,000/5,000/50,000/100,000 ppm
* Accuracy: ±2% FS, ±3% measured value @ 0 ~ 50'C
* Response Time: Every 2.0 Seconds
* Warm-Up Time @25'C: < 90sec
* Output support: UART, 0~3V Analog
* Operating Temperature: -10 ~ 50'C
* Operating Humidity: 0 ~ 99.5% RH (Non Condensing)
SH-300-NDC NDIR CO2 Sensor Module Features * Best Extremely Precise Sensor * Quick Response Time * Long Time Use, Stable performance at High & Low Temperature * Waterproof Filter for anti static filters fine dust and humidity in the air * One-way air indraft for represent average value when momentary CO2 Value change in the air * Low Current consumption * Output support: UART, 0~3V Analog SH-300-NDC NDIR CO2 Sensor Module Application * CO2 Control for Indoor Air Quality * CO2 Measuring for Ventilation Control * CO2 Control for Building, Hospital, School * CO2 Control for Air cleaner, Air conditioner. * Mushroom Control, Boiler Control SH-300-NDC NDIR CO2 Sensor Module Technical Specification * Measuring Type: Dual Light Wavelength NDIR * Measuring Range: 0 ~ 3,000 / 5,000 / 10,000 ppm * Accuracy: ±2% FS, ±3 % measured value @0 ~ 50'C * Response Time: Every 2.0 Seconds * Warm-Up Time @ 25'C: < 90sec * Output support: UART, 0~3V Analog * Operating Temperature: -10 ~ 50'C * Operating Humidity: 0 ~ 99.5% RH (Non-Condensing)
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
Ee893 digital co2 sensor module for oem applications The e+e co2 module ee893 is designed for oem applications and for demanding environment. A multiple point co2 and temperature adjustment procedure leads to excellent co2 measurement accuracy over the entire temperature working range; this is a must for process control and outdoor applications. The e+e dual wavelength ndir co2 sensing procedure compensates automatically for ageing effects. Ee893 is highly insensitive to pollution and offers outstanding long term stability. With its small dimensions and electrical connection via contact pins and pads, ee893 is the optimal choice for oem devices such as wireless transmitters, hand-helds or data loggers. The measured data, with a range of up to 10000ppm, is available on the e2 digital interface. An optional kit facilitates easy configuration and adjustment of the module. The measurement interval can be set according to the application requirements; by this the average current consumption can be reduced to less than 60î¼a for battery-operated devices. Ee893 digital ndir co2 sensor module typical applications * data loggers * hand helds * wireless transmitters * building management * demand controlled ventilation Ee893 digital co2 sensor module key features * autocalibration * outstanding long-term stability * temperature compensation * low power consumption * very small size Ee893 digital ndir co2 sensor module technical data * co2 working range: 0 - 2000 / 5000 / 10000ppm * supply voltage: 4.75 - 7.5v dc * average power consumption: 58âµa ~ 3.7ma * calibration interval: >5 years * operation temperature: -40~60'c (-40~140'f) * operation humidityâ??: 0~95% rh (not condensating) * operation pressure: 85~110kpa (12.33 ~ 15.95psi)
Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2 Features & Benefits: User-friendly operation, Easy-to-read display for multiple languages, Lightweight convenience, Ease of maintenance, Serviceability, The new 1-Series sensor for enhanced reliability, Connected Bluetooth Low Energy (BLE) capabilities.
SH-300-NDTH NDIR Carbon Dioxide Sensor Module Features * Best Extremely Precise Sensor * Quick Response Time * Long Time Use, Stable performance at High & Low Temperature * Waterproof Filter for anti static filters fine dust and humidity in the air * One-way air indraft for represent average value when momentary CO2 Value change in the air * Low Current consumption * Output support: UART, 0~3V Analog SH-300-NDTH NDIR Carbon Dioxide Sensor Module Application * CO2 Control for IAQ * Building, Hospital, School * Air cleaner, Air conditioner * Mushroom control, Boiler control SH-300-NDTH NDIR Carbon Dioxide Sensor Module Technical Specification * Measuring Type: Non-Dispersive Infrared (NDIR) * Measuring Range: 0 ~ 3,000 / 5,000 / 10,000 ppm * Accuracy: FS ±2%, measured value±3% @ 0 ~ 50'C * Response Time: Every 2.0 Seconds * Warm-Up Time @25'C: < 90sec * Output support: UART, 0~3V Analog * Operating Temperature: 0 ~ 50'C * Operating Humidity: 0 ~ 95%RH (Non Condensing)
Photocells Fans & ventilation, Hazardous area lighting Industrial plugs & sockets Industrial & commercial Lamps Light fittings: fluorescent, weatherproof & floodlighting Refrigeration & air conditioning spares Water heating elements Wiring accessories MCB's Circuit breaker Vacuum Breakers Control transformers Fuses & load break devices Hazardous area products Industrial beacons Industrial sounders, buzzers Industrial surge protection Safety switches Clamp meters Multi-meters Testers Semiconductors: thyristors, rectifiers Pressure switches Solenoid & pilot valves Photoelectric Sensors
Product Overview The ignition point of a fire inside the electric panel is mostly the part where the terminal block is fastened, so in order for initial fire extinguishing, the solution should be closely installed to the part where the terminal block is fastened. In the case of a small electric panel, a complete initial fire extinguishing is expected for fires occurring inside the electric panel by attaching the SFEX Pad to the top surface of the electric panel. Product Feature It has an excellent performance in the initial fire suppression as it can be installed near the ignition point as a flexible rope type. It uses a stand-alone method based on polymer chemistry so that it does not cause malfunctions and maintenance costs. The thermo-responsive Granule composed of KNO3 and subsidiary catalysts It does not affect the peripherals after the fire goes out. Function of SFEX Granule = fire extinguishing agent storage tank + temperature sensor + nozzle function Fire extinguishing method : Suffocation + subsidiary catalyst Example of Installation 1 : SFEX Line - If ducts exist Installing the SFEX Line horizontally or vertically in the ducts closest to the expected ignition points It can be installed without damaging the panel Example of Installation 2 : SFEX Line - If ducts do not exist Installing the SFEX Line horizontally or vertically, close to the expected ignition points of the Electric panel Example of Installation 2 : SFEX Pad - Small Electric Panel Simply attach it to the top inside the Electric panel.
High-Reliability CO2 Module For Various Applications IAQ, Greenhouse, HVAC * Use Dual Beam NDIR technology to improve the long term stability * Cost - effective CO2 monitors made with IR-SOC technology * Small Module for OEM ZG09 High-Reliability CO2 Sensor Module Application: * IAQ (Indoor air quality) * Greenhouse * HVAC.DCV (Demand Control Ventilation) ZG09 High-Reliability CO2 Sensor Module Specification * CO2 Measurement Range: 0~10,000ppm/1.0%?? * Operating temperature: 0~50'C (32~122'F) * Operating humidity: 0-95% RH, non-condensing * CO2 Accuracy: ±50ppm ±3% of reading * Repeatibility: ±20ppm * Resolution: 1ppm * Response Time: About 1 min
Introduction Irm300 is one of the general ndir co2 gas modules, which adopting ndir principle, consists of carefully designed light chamber, precise electric circuit and intelligent software. With the help of single light source, dual channel detector, and Unit Storage temperature Tstg -20 to 80 ¡ãc Working temperature Ta 0 to +50 ¡ãc Working humidity Ha 0 to 90 % rh Working pressure Pa 0.8 to 1.2 Atm Electric characteristics Description Symbol Min. Typical Max. Unit Supply power Vs 4.6 5 5.4 V Maximum current Imax 130 160- Ma Light current Iavg 60 70 Ma Frequency F 0.2 1 2 Hz Preheat time Twarm 90 120 180 Sec Performance characteristics Description Min Typical Max Unit Detection range 0 2000 50000 Ppm Detection accuracy - ¡¨¤60ppm¡¨¤5% fs - Ppm T90 Diffusing - 60 90 Sec Pumping - 10 20 Sec Repeatability Zero