Please click here to check who's online and chat with them.

4-Wire Uv Flame Detector With Relay Output

Supplier From China
Dec-26-17

v 4-wire UV Flame Detector with Relay output

General Description

The device is an Ultraviolet-only flame detector designed
to detect fires and provide alarm outputs directly from the
detector while maintaining false alarm immunity. It
detects in the ultraviolet (UV) spectral range for
optimized speed of response.
It is fast and capable to detecting the ultraviolet (UV) rays
emitted by a burning substance and is used in high hazard
applications such as petrochemical plants, munitions
factories and other areas where flammable or explosive
liquids or solids are handled or stored.
The flame sensor adopts an ultraviolet photosensitive
tube, with qualities of highly sensitive, reliable,
dust-resistant, corrosion proof and moisture-resistant,
therefore is not sensitive in sunlight, dust, oil, tolerance of
fume, and humidity. Set in a standard calibration to detect
a flames at a distance of 25 meters, which flame created
by 2Kg ethanol in a Container of Base 33cmX33cm,
Height 5cm.

Specifications

Operating Voltage Range: 12 to 28 VDC Volts
Standby Current: â?¤10 mA @ 24 VDC
Alarm Current â?¤40 mA @ 24 VDC
Spectrum: 180~290nm
Detection Angle: 120 degree
Detection Sensitivity: Grade I, 25m@flame (Container 33cmX33cm,Height 5cm with 2Kg ethanol )
Relay Contact Load: 1A@DC24V
Normal Status: LED blinking in 5 seconds interval
Alarm Status: LED lit steady
Protection rating: IP 21
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -20°C to 55°C
Height: 45 mm installed in Base
Diameter: 103 mm
Weight: 153g

Price and Minimum Quantity

Price: $95
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: 4-Wire Uv Flame Detector With Relay Output

GOLD Member
May-29-23
Supplier From Ahmedabad, Gujarat, India
GOLD Member
VERIFIED
Oct-28-24
Supplier From Faridabad, Haryana, India
Dec-26-17
 
Dry contact Explosion- proof UV flame detector A705/UV Fire alarm relay output Fault relay output EXdâ?¡CT6

Product function and composition

A705/UV can be applied to the need to monitor the implementation of the fire place, quickly found that the fire may cause the burning flame, issued in a timely manner

Fire alarm.

A705/UV using the cold cathode ultraviolet photoelectric tube to convert the flame combustion parameters into electric pulse signal, then the signal input is calculated.

Chip for operation and processing, with the UVdetecter@anysafe dedicated intelligent control software, can be issued in a timely manner to the fire alarm.

A705/UV uses the aluminum die-casting flameproof shell, has good protective properties and explosion-proof, corrosion resistance, aging resistance, can work for a long time

Indoor, outdoor, and various special industrial locations
Sensor sharp probe AE-S708/4 and AE-S708/5 infrared pyroelectric sensor

Optical window white gems (Al2O3)

housing

L material: aluminum alloy

L molding process: Die Casting

L coating process: surface electrostatic powder coating, internal metal passivation treatment.

The weight is less than 1kg

Explosion proof and protection l anti explosion: EXd II CT6

L protection: IP66
GOLD Member
VERIFIED
Oct-11-23

9Kg Co2 Fire Extinguishers

$8 - $5.00K
MOQ: Not Specified
Supplier From Kanpur, Uttar Pradesh, India
 
"Product name
Fire Extinguisher Cylinder
Type
0.5kg/0.8kg/1.2kg/1.3kg/1.35kg/Cutomized
Material
Steel
Usage
CO2 Fire Fighring
Keywords
Co2 Fire Extinguisher
Color
Customer Request
Working pressure
150bar"
GOLD Member
Sep-23-24
Supplier From Meerut, UP, India
GOLD Member
Mar-28-23
 
RP-2001 is a UL listed six-zone fire alarm control panel for single and dual hazard deluge and preaction applications, providing fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing.!
Features & Benefits:
1. Designed for sprinkler standards NFPA 13, 15 and 16.
2. Dual hazard operation.
3. Cross-zone (double-interlock) capability.
4. Six programmable Style B (Class B) IDCs (Initiating Device Circuit).
5. Optional Digital Alarm Communicators
GOLD Member
Mar-28-23
 
RP-2002 is a UL listed six-zone fire alarm control panel for single and dual hazard agent releasing applications, providing fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing.

Features & Benefits:

Disable/Enable control per input zone and output zone.
Extensive transient protection.
Dual hazard operation
Meets International Building Code (IBC) seismic requirements
GOLD Member
VERIFIED
May-16-25

Fire Extinguisher Ball, A Grade

$15.42 - $15.42 / Piece (EXW)
MOQ: 50 Cartons(12 balls / carton)  Cartons
 
"Total Weight - 1.3 KG
Diameter - 146mm
Activation Time - Approx 10 seconds
Warning Sound - 120 - 140 dBA
Fire Extinguish for an area - 3 Cubic Meters"

Key Specifications :
Work on all types of fire
Automatically activates upon contact with flames
Simple to use, no training required
Ideal for homes, offices, hotel, industrial settings
provides fast and reliable fire safety
No maintenance cost required for Agni Kawach fire extinguisher ball."
GOLD Member
May-15-25
Supplier From Mumbai, Maharashtra, India

Verification Status