Application:XLPE Cable is used indoor or outdoor, in tunnel, cable furrow or pipe, to be laid underground, be applicable to the well, water inside and fall in the bad soil.
Standards:IEC60502-2, BS7870-4, BS7870-7, BS7870-8
Cores: 1 Core, 3 Core
Conductor:Cu or Aluminum
Insulation:XLPE (Cross-Linked Polyethylene)
Armor:non-armor, steel tape armored, steel wire armored
Sheath:PVC or PE
Sheath Color:Black or Colors
PVC Power Cable The cable is used to keep working for some time under fire cases on the power line of rated 0.6/1KV power transmission and distribution. The product is produced according to the standard of GB/T12706-2008, GB/T 19666-2005, GA306-2007, IEC0092-1994. Fire-resistance features comply with the provisions of GB/T 19666-2005, GA306 and IEC61643 331-2003.
Product Description Standard The product is manufactured according to the standard of GB12706 and GB12666 or IEC,BS,DIN,ICEA, and JIS upon request. Application The product is suitable for use in power distribution lines or fixed installations with rated power-frequency voltage up to and including 0.6/1kV Operating characteristics Rated power-frequency voltage Uo/U: 0.6/1kV Max. Permissible continuous operating temperature of conductor(PVC/XLPE):70?/90? Max. Short-circuit temperature of conductor shall not exceed(5s maximumduration): PVC: cross-section of conductor=300mm2-160? cross-section of conductor=300mm2-160? XLEP:250? The ambient temperature under installation should not below 0? The bending radius of a single-core cable should not less than 20 times of the cable diameter. The bending radius of multi-core cable should not less than 15 times of the cable diameter. Packaging & Shipping In coils, wooden drums, steel drums or steel-wooden drums. We could producing according to the customers' requirements.
VOLTAGE:300/500V, 450/750V, 600/1000V CAPACITY:2000km/month Conductor:Class 1 solid or class 2 stranded copper conductor Separator:Mica/glass fire barrier tape Insulation:LSZH (Low Smoke Zero Halogen) or XLPE Protective Conductor:Tinned copper, full size CPC Bedding:LSZH (Low Smoke Zero Halogen) Screen:AL/PET (Aluminum/Polyester Tape) Armour:SWA (Steel Wire Armor), STA (Steel Tape Armor) Sheath:LSZH (Low Smoke Zero Halogen) or HOFR (Heat and Oil Resistant and Flame Retardant) to BS7655 or Heat resistant XLPE Sheath Color:Red, white, black
Copper Conductor XLPE Insulation SWA Power Cable fire resistant cable high quality
SFEX CT Manteau, also called the Cable Tray Manteau, is very efficient in extinguishing the initial fire suppression with immediate responses in case of fire because when a micro capsule for fire extinguishing reacts to a certain temperature and flame, it automatically disperses extinguishing agents. It\'s based on a cooling fire extinguishing method, shows an excellent characteristic of being able to extinguish a fire completely with an immediate response at the time of initial fire if you cover it over the electric power line. SFEX Solution : SFEX CT Manteau / SFEX AP Tape 1. Horizontal Section Fire : Access Floor, Cable Pit, and Cable Tray Installation and How It Works 1. Cover the SFEX CT Manteau. 2. Prevent the spread of fire with extinguishing/flame retardance properties 2. Vertical Section Fire Installation and How It Works 1. Wind the SFEX AP Tape on the cable. 2. Prevent the spread of fire with extinguishing/flame spread prevention properties Test Result : AP Tape Test Item Test Standard Unit Test Result Flame test of vertically placed cables The carbonization length should not exceed 2.5mm from the bottom edge of the burner - Do not exceed (carbonization length: 0.6m) During installation, photograph after installation *Test Information Test Facility Standard : KS C IEC 60332-3-10 : 2003(Compliant) Volume of nonmetallic material(L) per meter of test specimen : 1.5 (volume of nonmetallic material for finished cable, not including AP Tape) Number of test pieces : 5 Number of tiers : 1 Number of burners : 1 Position of test piece : Spatial type Flame application time (minutes) : 20 AP Tape installation method : AP Tape in 0.6/1 kV TFR-CV 4C 35 from the height of burner to the top 10cm gap between AP Tape and 20cm length of AP Tape
POWER CABLES Fire Resistant & Flame Retardant Cables Please contact us for for details catalogue
This cable will produce very little smoke and innocuous gas without halogen when burnt, it could definitely reduce the damage to the instrument, equipment and people. It was widely used in the crowded public place, such as high-rise building, hospital, library, gym, station, and mall. The plastic insulated cables (rated voltage: 35kV) produced by Qinshan Company, completely comply with GB/12706:2002, GB5023:1997 and GB9330:88, DJ08-93:2002; meanwhile, our flame retardant, low smoke and zero halogen cables comply with GB/T17650-1~2:1998, GB/T17651-1~2:1998, burning in the environment of 800 degrees Celsius or lower, ensure the conductor working at least 180 minutes, itâ??s twice of of the regular fire resistant cables. Models: WDZN-YJE: Copper core, XLPE insulated,Polyolefin sheathed Zero Halogen Low smoke Flame retardant Fire resistant power cable WDZN-YJE22: Copper core, XLPE insulated, Steel tape armoured, Polyolefin sheathed Zero Halogen Low smoke Flame retardant Fire resistant power cable WDZN-YJE32: Copper core, XLPE insulated, Fine steel wire armoured,Polyolefin sheathed Zero Halogen Low smoke Flame retardant Fire resistant power cable A. Single core - Nominal cross section area of conductor 2.5~630mm2 B. Cores: 2,3,4,5,3+1,3+2,4+1 - Nominal cross section area of conductor 4~300mm2
Supplier: Electrical Wires, Low Voltage Power Cables, Control Cables, Fire Resistant Power Cables, Aluminum Cables, Other Electrical Cables Ect.