High precision temperature transmission
Optimized for precision industry
Configurable analog signal transmission (4-20mA)
Communication via RS485 MODBUS (PC-HMI and PLC)
Built-in LCD
Simple and sleek design
High precision temperature transmission Optimized for precision industry Configurable analog signal transmission (4-20mA) Communication via RS485 MODBUS (PC-HMI and PLC) Built-in LCD Simple and sleek design
MS182 is a smart in-head transmitter module with HART® -protocol. It has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection, and converts various input signals into a standard 4 to 20 mA analog output signal after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use PC or the hand operator Measuring range Set via PC or by the hand operator Input type RTD, TC, R or Millivolt signal Convert accuracy 0.1£¥FS Cold junction accuracy ¡À1(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output HART ¨CProtocol output Max-load £¨V -13V£©/0.025A£¨Current output £© Limit current 25mA Response time 1s Isolated voltage 1500V AC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: 3.6mA or ¡Ý21.0mA Power supply 13¡«30V DC Temperature drift 0.01£¥ FS/1 Long-term stability 0.1 per year or 0.05 £¥per year Ambient -40¡«+85.
MS183 , a smart 2-wire in-head and dual-input transmitter module with HART® -protocol, has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection and converts various input signals into a standard 4 to 20 mA analog(high selector, average value or D-value) output signal or 2-way digtal output signals with HART® -protocol after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation also is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use PC or the hand operator Measuring range Set via PC or by the hand operator Input type Dual-input ( RTD, TC, R or Millivolt signal) Convert accuracy ¡Ü0.1£¥FS Cold junction accuracy ¡À1¡æ(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output HART ¨CProtocol output (2-way) Max-load £¨V -16V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Isolated voltage 1500VAC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: ¡Ü3.6mA or ¡Ý21.0mA Automatic switching while sensor damaged Power supply 16¡«30V DC Temperature drift 0.01£¥ FS/1¡æ Long-term stability ¡Ü0.1¡æ per year or 0.05 £¥per year.
Specification: 1.Supply voltage: loop power 18~32 vdc 2.Dcv input: 0~500 mv/ 0~1v/ 0~5v/ 0~10v/ 0~20v 3.Dca input: 0~20 ma/ 4~20 ma 4.Thermocouple input: k / j / t / e / r / s / b / n 5.Rtd/ resistance input: pt100/0~400w 6.Analog output: 4~20 ma (loop power) 7.Ambient temperature: -20~60c 8.Communication: hart 9.Galvanic isolation: 1500v Feature: 1.Isolation voltage: 1500 vac 2.Loop power 12~32vdc 3.Linear current output 4.Lcd display with 3 press buttons 5.Universal type with multi-signal input 6.With communication port for programming 7.Optional: hart Transmitter
NCS Series of Intelligent Transmitters are digital, intelligent, network-based, merged with advanced, reliable and stable sensor technology, to be designed as a new generation of Fieldbus Intelligent Transmitter. NCS Series of Intelligent Transmitter have been designed with high precision and high reliability, high stability. The pressure, temperature, currents and other physical quantities are displayed on LCD module. Zero drift, range settings and many other functions, are realized by the magnetism bar operation. The interoperability between different systems and equipments are realized by the Equipment Description Document, which is compatible to a variety of device management software, and adapting to harsh electromagnetic environment. NCS Series of Intelligent Transmitter have been used in inflammable and explosive places according to Intrinsically Safety Design. The Fieldbus Technology is used in NCS-TT105 Intelligent Temperature Transmitter, which is a new generation of Fieldbus Intelligent Temperature Transmitter, also an indispensable field device in control processing. It is integrated with a variety of functional modules, to realize not only the general testing functions, also the complicated control strategy. Digital technology is applied in NCS-TT105, which has been used in a wide range of thermal resistance and thermocouple sensors. It has a wide measuring range. Because of the simple interface between the field and control room, the costs of installation, operation and maintenance are reduced a lot. NCS-TT105 Series of Intelligent Temperature Transmitters, complied with FF Protocol, have been widely used in petroleum, chemical, metallurgy, electricity, cement,etc. Thermo resistance additional parameters as follows: Parameter Function Description COMP_WIRE1 Linearization compensation for thermo resistance 1 selecting 2-wire or 3-wire. Unit is fixed as Ω. COMP_WIRE2 Linearization compensation for thermo resistance 2 selecting 2-wire or 3-wire. Unit is fixed as Ω. SENSOR_CONNECTION It can be used to connect sensor with 2-wire or 3-wire. 0: 2-wire 1: 3-wire
Product Overview NCS-TT106 smart temperature module, using the fieldbus technology, is a new generation of smart fieldbus temperature transmitter and it is an indispensable field device for process control. Features Support multiple thermal resistance and thermocouples Thermal resistance supports 2/3/4-wire connection mode Thermocouple can use cold end compensation function Better accuracy: PT100 ±0.3 ; K-type ±0.4 Universally programmable for various input signals Available protocols: HART /FF H1 /PROFIBUS PA Parameter Value Input Signal Resistance: PT100, CU50, CU100, 0~500Ω, 0~4000Ω Thermocouple: B, E, J, N, K, R, S, T Voltage signal: -100mV~100mV Channel Single RTD Wiring 2-wire, 3-wire, 4-wire Bus Power 9~32 VDC Current consumption (static): â?¤14mA Bus Signal Communication ratio 31.25Kbit/s, current mode Isolation Between terminal and housing: 1kV Working Temperature -40~85 Humidity Range 10%~90%RH Start Time â?¤5s Refresh Time 0.5s EMC GB/T 18268-2000 Protection IP20 Signal Type Suggested Range () Accuracy Resistance 0~500Ω,0~4000Ω ±0.05% PT100 -200 ~ 850 ±0.2 PT1000 -200~ 850 ±0.1 CU50 -50 ~ 150 ±0.3 CU100 -50 ~ 150 ±0.2 mV -100mV ~ 100mV 0.05% B 500 ~ 1810 ±1.0 E -200 ~ 1000 ±0.4 J -190 ~ 1200 ±0.4 K -200 ~ 1372 ±0.4 N -190 ~ 1300 ±0.8 R 0 ~ 1768 ±1.0 S 0 ~ 1768 ±1.0 T -200 ~ 400 ±0.4
CAEL-S16 Probe Humidity and Temperature Transmitter CAEL-S16 Humidity and Temperature Transmitter Features * Metal probe reduce electromagnetic interference * Interchangeable sensor for rapid maintenance * 0 - 100%RH measurement, * Probe pressure up to 10 bar * Calculated hygrometric outputs * Two channel with selectable physical quantity * Unit support metric or imperial CAEL-S16 Humidity and Temperature Transmitter Applications * Semiconductor and microelectronics industry * Food production and packaging * Agriculture, farms * Environmental chambers, drying equipment, spraying equipment * Greenhouse, storage room, cooling chamber * HVAC
CAEL-HT Series Multi-function Humidity and Temperature Transmitter SERIAL's latest CAEL series Temperature and Humidity transmitter meets the harsh environmental requirements for temperature and humidity measurement. Via temperature and relative humidity values, the output can be calculated dew point temperature, absolute humidity, wet bulb temperature, the specific enthalpy and other parameters of humidity. CAEL series Temperature and Humidity transmitter supported wall mount type, duct type and remote probe type. Metal probe provides a high temperature, mechanical stress, pressure and withstand harsh environments generated by the fine waterproof housing can avoid environmental contamination and prevent condensation generated. Parameter values measured through the two analog output channels, the output may be a current or voltage output. You can simply establish a network by RS485 connection to achieve remote monitoring and data logging, measurement data through the storage device for analysis and processing. LCD monitor would displays three measurement parameters at the same time, or the font is enlarged for single display to provide different visual needs. Touch buttons without having to open the housing can be set a one point adjustment for temperature and humidity, output selection, range setting, adjustment parameters, and do not carry the computer in the environment field will be able to complete the setup work. CAEL-HT Series Humidity and Temperature Transmitter Features * Remote probe w/M12 connector * Metal probe reduce electromagnetic interference * 2-wire 4-20mA with selectable physical quantity * 0 - 100%RH measurement, temperature range up to +120'C (248') * Probe pressure up to 10 bar * Display and touch buttons for convenient operation * Excellent quality and stable measurement * IP-65 housing *1-point user adjustment * Analog output and RS485 * MODBUS RTU protocol with integer and floating type * Unit support metric or imperial * Alarm output * Dip switch setting * Configure adapter support CAEL-HT Series Humidity and Temperature Transmitter Applications * Semiconductor and microelectronics industry * Pharmaceutical industry, paper industry * Environmental chambers, drying equipment, spraying equipment * Agriculture, farms * Greenhouse, storage room, cooling chamber * Building Automation * Environment and ventilation control
CAEL-S16 Humidity and Temperature Transmitter Features * Metal probe reduce electromagnetic interference * Interchangeable sensor for rapid maintenance * 0 - 100%RH measurement, * Probe pressure up to 10 bar * Calculated hygrometric outputs * Two channel with selectable physical quantity * Unit support metric or imperial CAEL-S16 Humidity and Temperature Transmitter Applications * Semiconductor and microelectronics industry * Food production and packaging * Agriculture, farms * Environmental chambers, drying equipment, spraying equipment * Greenhouse, storage room, cooling chamber * HVAC