Description
Multi Tap Transformers allow greater flexibility in managing multiple wire runs by moving cables up and down the multi range. Our Resin Sealed Transformers ensure highest possible efficiency & reliability.
Features
Low Voltage Transformer ranging from 75 W - 1200W 120, 277 /12, 13, 14, 15V with Toroidal /EI.
50/60 Hz
Protection for each output circuit.
Photo cell Option
Rainproof Enclosure
Stainless Steel / Powder Coated.
Product Details : The Transformer used in the power supply unit is manufactured as per the UL norms. The transformer will be potted/sealed in an enclosure using Epoxy (a mixture of Resin Hardener) which ensures high reliability and efficiency. The enclosure is made up of Prime Stainless Steel material SS 304 grade (also carbon steel with powder coated enclosure can be provided on request ) Block Terminals will provide the easiest way for the customer to connect the secondary tappings. Photocell and timer connected as per the customer's needs. A circuit breaker of 25A is provided for circuit protection. Technical Details Wattage - 300w Frequency - 50/60 Hz Pry. voltage - 120V /277V Sec... voltages As per customer requirements Insulation class F, H Max. regulation 10% Dielectric 2000v, primary to secondary for 1 second. Dielectric 2000v, all windings to lamination for 1 second.
GRES is an intelligent and modular power supply equipment integrating lithium battery and MPCS. According to different application scenarios, lithium battery, bidirectional DC / AC converter, bidirectional DC / DC converter, Static switch and Power management system can be arbitrarily combined to realize grid connected power supply, off grid power supply and off grid uninterrupted power supply power supply, static reactive power compensation, harmonic suppression and other functions. The system can have access to new energy, power grid, diesel generator and to rreasonable configuration, scientific utilization, to provide users with green, environmental protection, noise free, high reliability and high security power services. Safe and reliable High quality li-ion cell for mobile use Laser welding connection with high strength and low impedance Cells is designed with PC holders and reinforce steel structure to guarantee the highest safety of the system in transportation, installation and operation Damping pad design to improve the impact resistance of the system IP54 safe and reliable operation in outdoor environment Serially designed PCS and battery pack eliminates circulating current and improve system reliability. Integrated BMS,DC, AC multi-layer protection, maximum safety performance design Efficient and Convenient Integrated system, standard modular power module and battery module, easy for installation, maintenance and capacity expantion Easy access to PV and diesel generator, intelligent muli-energy management. Fixed on the ground or mounted on vehicle, can be loaded and unloaded by forklift and hoisted by lifting ring Multi systems could be connected in parallel Cost optimization One investment, multiple benefits:Peak shaving, backup power supply, microgrid building,power quality improving and energy storage,etc. Small size, light weight, less space and installation cost Long cycle life, low failure rate, reduce operation and maintenance investment Maximize green energy utilization. Rated output power: 100KW Rated energy: 150KWH
GRES is an intelligent and modular power supply equipment integrating lithium battery and MPCS. According to different application scenarios, lithium battery, bidirectional DC / AC converter, bidirectional DC / DC converter, Static switch and Power management system can be arbitrarily combined to realize grid connected power supply, off grid power supply and off grid uninterrupted power supply power supply, static reactive power compensation, harmonic suppression and other functions. The system can have access to new energy, power grid, diesel generator and to rreasonable configuration, scientific utilization, to provide users with green, environmental protection, noise free, high reliability and high security power services. Safe and reliable High quality li-ion cell for mobile use Laser welding connection with high strength and low impedance Cells is designed with PC holders and reinforce steel structure to guarantee the highest safety of the system in transportation, installation and operation Damping pad design to improve the impact resistance of the system IP54 safe and reliable operation in outdoor environment Serially designed PCS and battery pack eliminates circulating current and improve system reliability. Integrated BMS,DC, AC multi-layer protection, maximum safety performance design Efficient and Convenient Integrated system, standard modular power module and battery module, easy for installation, maintenance and capacity expantion Easy access to PV and diesel generator, intelligent muli-energy management. Fixed on the ground or mounted on vehicle, can be loaded and unloaded by forklift and hoisted by lifting ring Multi systems could be connected in parallel Cost optimization One investment, multiple benefits:Peak shaving, backup power supply, microgrid building,power quality improving and energy storage,etc. Small size, light weight, less space and installation cost Long cycle life, low failure rate, reduce operation and maintenance investment Maximize green energy utilization. Rated output power: 150KW Rated energy: 225KWH
Transformers,Distribution and Power Transformer,Varivolt Safety Transformers Diesel Generators Industrial Panels Stabilizers Energy Saver Industrial Panels
This series of power supplies can generate output that ranges from 1kV to 100kV, 50W to 20kW and are housed in compact MS cabinets to give a highly regulated output
Fuji Electric's UPS and power solutions have the best product specifications with the latest technology. Fuji's products are available in the 72 VA to 2000 kVA range, for single modules. For higher ratings, these can be paralleled to deliver 12000 kVA. Fuji Electric's high efficiency UPS helps in reducing costs, weight, footprint and heat.
Supplier: Gypsum products, gypsum board, ceiling tiles, suspended ceiling, flooring tiles, all kinds furniture, shoes, generators, cement, biscuits, chocolates, jeans, t shirts, sweatshirts
High voltage power supply (HPS) for image intensifier is an electron converter that is an ability to transform from low voltage of direct current into once or a series of high voltage of direct current (DC/DC Converter). It consists two assembly an oscillator module and a high multiplier module. Features: Small size, lightweight wrap-around construction Automatic brightness control (ABC) Bright source protection (BSP) Adjustable maximum brightness and gain External gain adjustment Conform to environmental requirement of military products High accurancy control Programmable Fast stable response Large range for pulse width Applications: Image intensifiers
Low, medium and high voltage transformers 110kV Class Power Transformers General The110kV class low loss transformers are developed by Huapengour workshop through years of service experience and careful analysis of the advantages and disadvantages of the transformers of different manufacturers, both domestic and abroad, and are featured by low loss, low partial discharge, low noise, high strength against short circuit, and high reliability in service. Its outstanding performance has won high reputation throughout China, and the world, and are highly appreciated by experts of the circle. Transformers can be made with welded tank cover and/or flange , Thus obviated from the necessity of lifting out the active part for inspection after arrival on site. Partial discharge level: apparent discharge < 80pC at 1.5 times rated voltage. Noise level : below 58 dB for transformers 63MVA and below with AN cooling Losses: no-load loss 30% lower than specified by GB/T 6451-1995 Reliability: no damage or oil leakage have been found in transformers in service up to the present Short-circuit withstand capability: Our SZ9-31500/110,SSZ-50000/110 transformers successfully passed short-circuit test in National Transformer Quality Inspecting and Testing Center, and in CESI Laboratory of Italy. Winding 1. Partially interleaved continuous winding is used for HV winding to improve its behavior under lightning impulse, because of its more uniform voltage distribution. 2. All the spacers and vertical strips are rounded at corners, in order to obtain a more reliable insulation structure. 3. Zig-Zag directional flow is provided inside the windings, so that all parts of the windings are better cooled, resulting in lower winding temperature rise, and specifically lower hot-spot temperature, thus the insulation life of the transformer is prolonged. 4. Separate regulating windings are provided for both the 110kV high voltage and the 35kV medium voltage side, so that a more balanced ampere-turn is obtained in spite of tap-changing, the short-circuit withstand capability is thus promoted. Radially, the windings of a phase assembly are tight-fit, little space is left between the core and the low-voltage cylinder, and between the windings. All the vertical strips and cylinders are thoroughly dried before assembly, so that a tight phase assembly can be finally obtained. Core 1. High permeability grain oriented high quality cold-rolled sheets are used for the fabrication of core. The sheets are cut on automatic cutting line made by Georg Co. of Germany or Soenen Co. of Belgium. The burrs are controlled within 0.02mm. 2. The core is stacked without stacking the upper yoke, the upper yoke sheets are placed into position after the winding blocks are mounted on the core. The joints of the core sheets are mitred 45fpjoint with step-lap. The stacked core is pressed under even pressure and the edge of the sheets are painted with epoxy resin, so that a straight, robust, integral structure is obtained, helping to reduce core loss and noise. 3. Wooden strips are driven into the space between core and LV cylinder. The yoke is kept tightened by epoxy-resin impregnated glass tape, while the lower yoke is pressed against the wall of the lower tank through threaded bolts. The active part of the transformer is in addition kept in position by devices at three places between the upper yoke and the tank cover in such a way that the active part cannot be displaced during transportation.