We manufacture transformer bushings for outdoor and indoor applications and our manufacturing program includes the following ranges :
1. Low voltage bushings in accordance with DIN 42539
- 1 kV , 250 A Low voltage bushing AB-250
- 1 kV ,630 A Low voltage bushing AB-630
- 1 kV ,1000 A Low voltage bushing AB-1000
- 1kV, 2000 A Low voltage bushing AB-2000
- 1 kV,3150 A Low voltage bushing AB-3150
2. Medium voltage Bushings in accordance with EN50180 & DIN42531
- 12.5kV,250A Indoor type transformer bushing 10Ni-250A
- 12.5 kV,250A Outdoor type transformer bushing 10Nf -250A
- 24 kV ,250A Outdoor type transformer bushing 20NF-250A
- 36 kV,250A Outdoor type transformer bushing 30NF-250A
Hebei Anmei produce kinds of DIN standard , ANSI standard , AS standard transformer bushing insulator, oil level gauge and transformer accessorise
Transformers,Distribution and Power Transformer,Varivolt Safety Transformers Diesel Generators Industrial Panels Stabilizers Energy Saver Industrial Panels
Supplier: Transformers and other electrical products, clothing, cosmetics, general merchandise
Supplier: Japanese quality switchgear components, breakers, magnetic contactors, switches, pilot lights, pushbuttons, panel instrumentations, power management meter, protection relays, transformers, inverters, ups.
JDZX10-12 voltage transformer, epoxy resin casting and single pole insulated VT, is widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest voltage for equipment 12 kV. Usage Terms J: Voltage transformer D: Single-phase Z: Casting insulation X: Residual voltage winding 10: Design No. 12: Rated voltage Main technical parameter 1. Rated primary voltage:11/kV or 10/kV etc. 2. Rated secondary voltage:100/V?110/V ? 115/V? 120/V 3. Rated voltage of residual voltage windings:100/ 3V ?110/ 3V? 115/ 3V? 120/ 3V 4. Burden power factor: cosF=0.8(lagging) 5. Standards: IEC60044-2.2003 Instrument transformers-Part2: Inductive Voltage transformers Other technical parameters pls see as follow: x1204.png Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.
LZZBJ9-12A1(A2) current transformer, epoxy resin casting insulation and fully enclosed support construction, encloses primary & secondary windings and annular core in the epoxy resin casting body. The product has the feature of light weight, omni-directional installation, withstanding nastiness and dampness. It is widely used for measuring current, electric energy and protective relaying in the electrical system with the rated frequency 50- 60Hz and highest voltage for equipment 7.2 kV /12 kV . Main technical parameter 1. Rated voltage: 6.6 kV or 11 kV etc. 2.Rated secondary current: 5A?1A 3.Rated insulation level: 7.2/20/60 kV or 12/28/75 kV 4.Standards: IEC60044-1.2003 Part 1: Instrument transformers-Part1: Current transformers 5.Other technical parameter pls see as follows Rated transformation ratio(A) Accuracy classes combination Rated output(VA) (ALF) (FS) Short-time thermal current Ith(kA/S) Rated dynamic current Idyn(kA) Measuring Protective 0.2(S) 0.5 10P 10-200/5 0.2(S)/0.2(S) 0.2(S)/0.5 0.2(S)/10P 0.5/10P 0.2S/0.5/10P 0.2/0.5/10P 10 15 15 15 10 15 20 5 (10) 150I1n 375I1n 300/5 31.5 80 400/5 31.5 80 500/5 40 100 600/5 50 125 800/5 20 63 125 1000/5 80 160 1200~1500/5 80 160 1500~2000/5 100 160 2000~3150/5 130 160 Rated transformation ratio(A) Accuracy classes combination Rated output(VA) (ALF) (FS) Short-time thermal current Ith(kA/S) Rated dynamic current Idyn(kA) Measuring Protective 0.2(S) 0.5 10P 10-200/5 0.2S//0.5/ 10P 0.5/0.5/10P 10 15 15 15 20 10 15 5 (10) 150I1n 375I1n 300/5 31.5 80 400/5 31.5 80 500/5 40 100 600/5 50 125 800/5 63 125 1000/5 80 160 1200~1500/5 80 160 1500~2000/5 100 160 2000~3150/5 130 160 Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.
Hebei anmei company produces various transformer accessories. The main products include high-voltage and low-voltage transfomrer bushings (DIN standard, ANSI standard, AS standard, and so on.), oil level gauge, dehydrationg breather, release valve, thermometer, valve, butterfly valve, brass gate valve, bellows, terminals,dry change accessories and so on. company can also be produced according to customer drawings. The products are exported to all world, Asia, the Middle East, South America, Europe, and so on.
DIN Standard Bushing for Transformer12kv 24kv 36kv 250A Electrical Porcelain Insulator DIN(12~36kV/250~630A ) Sequence Number Code Model (Dimensions) Opening arcing distance Creep distance Shield Weight(kg) H h2 h3 Md d1 d3 d4 E C d0 h1 1 AM.DDA.001 DIN-12/250 427 125 60 M121.75 140 74 51 146 70 78 174 300 2 5.3 2 AM.DDD.001 DIN-12/630 475 140 75 M202.5 150 88 60 174 70 92 174 310 2 8 3 AM.DFA.001 DIN-24/250 517 140 60 M11.75 145 74 51 146 100 78 249 440 3 7.2 4 AM.DFD.001 DIN-24/630 565 155 75 M202.5 160 88 60 174 100 92 249 460 3 10.4 5 AM.DGA.001 DIN-36/250 617 140 60 M121.75 155 74 51 146 200 78 349 610 4 8.3 6 AM.DGD.001 DIN-36/630 690 175 75 M202.5 180 88 60 174 200 92 354 670 4 13.5 7 AM.DGA.010 DIN-36/250 617 135 55 M121.75 190 74 51 146 200 78 354 950 6 12.5