1. Adopting digital filter technology
2. Selectable 50hz or 60hz band stop filter
3. 500hz¡¡é7 lead synchronous sample and anlysis
consumption and safely insulation
7. 5v ttl communication
8. 2-channel temperature detect , and two sort of sensor model
9. Detecting respiration by impedance between ra-ll
Provide three¡¡éand five lead system with arrhythmia analysis function Adopting digital filter technology Selectable 50hz or 60hz band stop filter 500hz 7/12 lead synchronous sample and anylsis Character classification up to tweel sort, and 3 channel st segment monitoring
Advanced dsp algorithm monishes the influence of motion artifact All digital-signal processing improves accuracy of low perfusion Small size easy to be assem ble A wealth of experience in r&d, with perfect quality in the measurement precision
Measurement accuracy reaches medical grade Test speed is 30s Weak signal test (cufflink simulator test) is 20% Blood pressure measuring range 40 ~ 255mmhg Pulse rate 30bpm-~ 240bpm Resistantof occasional interference movement, support serial, support the hibernation feature
Features: 1.English menu display 2.Lead off/on signal by indicator light 3.Selectable multi-recording modes:3 channels,3 channels + rhythm 60 sec compressible: select simultaneously acquisition of 12-lead ECG signals 4.Automatic diagnosis and analysis 5.Save the half record paper and the half record time 6.The body check mode can record the patient ECG 15 seconds/each 7.Thermal printer (dot array),40 dot/mm,precise waveform 8.Rechargable battery pack 9.Hidden handle. Specifications: Acquisition mode: simultaneous 12 leads Operating mode: auto/manual Recording format: auto/manual/simultaneously 60 sec compressible LCD display: operation mode/ Status, HR Input Condition: against defibrillation Input impedance: >50MQ Patient Leakage Current: 3.2 s CMRR: > 100dB Filter:50Hz or 60 Hz (-20dB) prift(0.5Hz-3dB) Sensitivity Option: Auto,2.5,5,10,20,40mm/mv=2% Resist to polarization voltage:=500mV Electrical noise level:
Features: 1.English menu display; 2.Lead off/on signal by indicator light; 3.Selectable multi-recording modes:single channel, 2 channels,2 channels + rhythm; 60 sec compressible: select simultaneously acquisition of 12-lead ECG signals; 4.Save the half record paper and the half record time; 5.The body check mode can record the patient ECG 15 seconds/each; 6.Thermal printer (dot array),40 dot/mm,precise waveform; 7.Rechargable battery pack; 8.Hidden handle. Specifications: Lead: Standard 12 leads Acquisition mode: simultaneous 12 leads Operating mode: auto/manual Recording format: auto/manual/simultaneously 60 sec compressible LCD display: operation mode/ Status,HR Input Condition: against defibrillation Input impedance: >50MQ Patient Leakage Current: 3.2 s CMRR: > 100dB Filter:50Hz or 60 Hz (-20dB) prift(0.5Hz-3dB) Sensitivity Option: Auto,2.5,5,10,20,40mm/ mv=2% Resist to polarization voltage:=500mV Electrical noise level:
Ecg workstation gl8000 Specification: 1. Sample rate: 1000Hz, simultaneous 12 leads recording 2. Resolution:12bit 3. Power: 5.0V (DC) 4. Patient Insulation: 4000V AC 5. Defibrillation Protection: Built-in box 6. Digital resolution: 2 V 7. Frequency response: 0.05-250 Hz 8. Common mode rejection: >90dB 9. Input impedance: >10M 10. Time constant: í¦3.2 s 11. Max electrode potential: í+300mV DC 12. Dynamic range: í+10mV 13. Isolate voltage: 4000V 14. Current leak:
GE Healthcare MAC 500 ECG / EKG Machine with rolling cart Main Mac 5500 HD ECG Console CAM HD ECG Acquisition Module Rolling Cart Power Cord
Supplier: Nibp module, ECG module, digital SPO2 module ECG machine, patient monitor, mobile BP monitor, accessories of patient monitor
Supplier: ECG machine, ECG module, NIBP midule, SPO2 module, smart blood pressure device, patient monitor, gel warmer