Features:
1.English menu display
2.Lead off/on signal by indicator light
3.Selectable multi-recording modes:3 channels,3 channels + rhythm 60 sec compressible: select simultaneously acquisition of 12-lead ECG signals
4.Automatic diagnosis and analysis
5.Save the half record paper and the half record time
6.The body check mode can record the patient ECG 15 seconds/each
7.Thermal printer (dot array),40 dot/mm,precise waveform
8.Rechargable battery pack
9.Hidden handle.
Specifications:
Acquisition mode: simultaneous 12 leads
Operating mode: auto/manual
Recording format: auto/manual/simultaneously
60 sec compressible
LCD display: operation mode/ Status, HR
Input Condition: against defibrillation
Input impedance: >50MQ
Patient Leakage Current: <10mA
Input Circuit Current: 50nA
Calibration Voltage: 1mv=2%
Output Voltage: 1mv=5%
A/D Conversion: 20bit
Frequency Response: 0.05-150Hz(-3dB)
Time Constant: > 3.2 s
CMRR: > 100dB
Filter:50Hz or 60 Hz (-20dB) prift(0.5Hz-3dB)
Sensitivity Option: Auto,2.5,5,10,20,40mm/mv=2%
Resist to polarization voltage:=500mV
Electrical noise level: <15uVp-p
Power supply
AC:220V/110V50/60Hz
DC:12V rechargeable battery
Up to 50 patients recording
Supply continuously
Safety level: IEC60601-1 class I , type CF
Recording mode: thermal printer(dot array)
Analysis system: auto ECG measurement
Exterior input: 10mm/v=5%
Single port input: 10K
Channel:3CH, 3CH+1(Phythm), 5CH
60 sec compressible
Recording speed: 5,10,12.5,25,50mm/s
Paper size: 80mmwidth, 20m length
N.W:2.2Kgs, G.W: 4.0Kgs
Size: 290mmX200mmX70mm.
Features:
1.English menu display;
2.Lead off/on signal by indicator light;
3.Selectable multi-recording modes:single channel, 2 channels,2 channels + rhythm; 60 sec compressible: select simultaneously acquisition of 12-lead ECG signals;
4.Save the half record paper and the half record time;
5.The body check mode can record the patient ECG 15 seconds/each;
6.Thermal printer (dot array),40 dot/mm,precise waveform;
7.Rechargable battery pack;
8.Hidden handle.
Specifications:
Lead: Standard 12 leads
Acquisition mode: simultaneous 12 leads
Operating mode: auto/manual
Recording format: auto/manual/simultaneously
60 sec compressible
LCD display: operation mode/ Status,HR
Input Condition: against defibrillation
Input impedance: >50MQ
Patient Leakage Current: <10mA
Input Circuit Current: =50nA
Calibration Voltage: 1mv=2%
Output Voltage: 1mv=5%
A/D Conversion: 20bit
Frequency Response: 0.05-150Hz(-3dB)
Time Constant: > 3.2 s
CMRR: > 100dB
Filter:50Hz or 60 Hz (-20dB) prift(0.5Hz-3dB)
Sensitivity Option: Auto,2.5,5,10,20,40mm/
mv=2%
Resist to polarization voltage:=500mV
Electrical noise level: <15uVp-p
Power supply
AC:220V/110V;50/60Hz
DC:12V rechargeable battery;
Up to 50 patients recording
Supply continuously
Safety level: IEC60601-1 class I , type CF
Recording mode: thermal printer(dot array)
Analysis system: auto ECG measurement
Exterior input: 10mm/v=5%
Single port input: =10KO
Channel:1CH, 2CH, 2CH+1(Phythm), 3CH
60 sec compressible
Recording speed: 5,10,12.5,25,50mm/s
Paper size: 50mmwidth, 20m length
N.W:2.2Kgs, G.W: 4.0Kgs
Size: 290mmX200mmX70mm.
1.Notebook style,special backpack,lightweight and convient
2.Intelligent ports, 5 available different probes
3.Portable and trolley optional
4.7 segment intelligent STC adjustment, high resolution images
5.Low radiative 15 inch TFT LCD display
6.Great capacity of cineloop ,high definition dynamic images
7.Chinese and english operation interface.
Specifications:
Scanning Mode: wide frequency electronic Convex/ Linear
Display Mode: B, B+B, B+M, M, 4B, 8B
Scanning Depth: 220 mm
Gray Scales Transformation: gamma correction
Image Magnification: 1.0, 1.2, 1.5, 2.0
Monitor: 15 inch TFT LCD display
Image Conversion: up and down, left and right, black and white
Focusing: variable aperture for section 1,2,3,and 4 available
Electronic Focuses: 4 sector dynamic ( Random Combination )
Probe FRE. Support: Convex, Linear, Micro convex, Vaginal, Rectum
Resolution: Lateral less than 2mm, Axial less than 1mm
Body Marks: 24
Obstetric calculation: BPD, FL, CRL, GS, HC, AD AC, and display fetus age, fetus weight, expected birth date, heart rate, slope ratio, period.
Measurement: Distance, Circumference, area, heart rate, EDD, etc.
Pseudo-color: 8 available colors
Display: Date, Time, Name, Sex, Age, Hospital, Obstetric list, annotation, edit menu, etc.
Video Output: PAL, VGA
Size:280mmX240mmX210mm
Net Weight: 6.5Kg.
Features:
1. Laptop design
2.
3. 8 TGC controls
4. High-quality images
5. Broadband multi-frequency transducers
6. Leading digital technologies: Digital beam forming, Real time dynamic filtering,
Dynamic frequency scanning, Real time dynamic aperture
6. Cineloop
7. Two USB ports
8. Two probe connectors
9. Pseudo colors.
Technical Specifications:
Display: 15 inches high-resolution LCD
Scanning Mode: Electronic convex array, Electronic linear array
Display Mode: B, B+B, B+M, M
Magnification: X0.8,X1.0,X1.2,X1.3,X1.5,X1.6,X1.8,X2.0
Gray Scales: 256 shades
Y adgustment: A,B,C,D,E,F,G,H
Resolution: Horizontal less than 2mm, Vertical less than 1mm
Geometrical Precision: less than 5%
Blind Area: less than 3mm
TGC: 8 section TGC adjustment
Pseudo Colors: Yes
Display Depth: 240mm and depth could be increased
Image Polarity: Left/right, Positive/negative and up/down
Cineloop: Successive 256 frames
Output Lnterface: Three output interface 1 VGA and 2 PAL video signal output
Power Supply Range: AC 110V 60Hz, 220V 50Hz
Net Weight: 6.5Kg
Size: 280mmX240mmX210mm.
ECG cables also referred to as an ECG patient cable, is a type of cable connection designed for non-invasive heart monitoring, typically used to help diagnose potential heart issues. The ECG cable connects to electrodes which are positioned at specific locations on the patient�¢??s body to detect and record heart muscle electrical activity. The cables then transmit the electrical activity back to the ECG device for analysis and diagnosis by medical professionals.
ECG Cable Feature
[Multiple Leads]: ECG cables usually have several leads placed in specific areas on the patient�¢??s body, such as the chest, arms, and legs, to measure the heart�¢??s electrical activity from different angles.
[Durability]: ECG cables are constructed from top-quality, sturdy materials that can endure repeated bending, tugging, and
twisting without sustaining any damage. This ensures that the cables can withstand the rigors of frequent use and remain reliable over time.
[Shielding]: ECG cables are shielded to block out external electrical signals, which can interfere with the accuracy of the
readings.
[Connector Compatibility]: The ECG cables are available with various connector types, including snap, clip, and banana, to fit different types of ECG machines.
[Safety]: ECG cables are designed to meet strict safety standards and regulations to ensure patient safety. This helps to ensure that patients are protected from any potential harm during the monitoring process.
[Cleaning and Disinfecting]: The ECG cables are easy to clean and disinfect to maintain hygienic conditions, as they come into contact with the patient�¢??s skin.
ECG Cable Advantages
[Excellent Performance]: ECG cables are built to withstand the rigors of twisting and bending, and have been thoroughly tested to ensure optimal performance. The cables are also equipped with electrical shielding to protect the signal integrity, ensuring accurate readings.
[Non-Invasive]: ECG cables are non-invasive, which means that they do not require any incisions or invasive procedures. This reduces the risk of infection and makes the monitoring process much safer for patients. Instead, the cables are simply attached to the patient's skin, making it a quick and painless process.
Pulse Oximeter is a non-invasive device intended for the spot-check of oxygen saturation of arterial hemoglobin (SpO2) and the pulse rate of adult and pediatric patients in home and hospital environments (including clinical use in internist/surgery, anesthesia, intensive care ect.). This device is not intended for continuous monitoring.
Major Features
1)value display
2)Pulse rate value display, bar graph display
3)Pulse waveform display
4)PI value display
5)The display mode can be changed
6)Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage
7)Pulse sound indication and over limit indication
SpO2 cables are specifically designed to connect the SpO2 sensor, typically placed on a patient's finger or earlobe, to the monitoring device. These cables transmit the optical signals captured by the sensor to the monitor, where the data is processed and displayed as oxygen saturation levels.
EMSCULPT is the only procedure that can help both women and men burn fat and build muscle. Dr. Busso was part of the BTL Aesthetics EMSCULPT development team and was the first physician in Thailand to offer this exciting new technology to patients.
Particularly effective on the buttocks and abdomen, EMSCULPT uses High-Intensity Focused Electro-Magnetic (HIFEM) field technology to induce short bursts of powerful muscle contractions that lead to increased muscle density, decreased volume, better definition, and improved tone.
Product Specifications :
Max. Power : 200 Watts
Output Frequency : 27.12 MHz
Treatment Duration : 1 to 30 min
Mode : Continuous
Output Power : 0 W - 200 W
Dimensions of Device : 22 in W x 39 in H x 22 in D
Weight of Device : 84 lbs
Graphic Color Touch Screen : 8.4", 640x480 pixels
Dimensions of Applicator without Cable : 27 in W x 7.6 in H x 4.1 in
Weight of Applicator : 3.9 lbs
KEY FEATURES :
Builds muscle
Burns fat
Together!
Non-invasive buttock lifting procedure
No surgery
No anaesthesia
Suitable for everyone
only a 30 minute walk in walk out procedure
Only 4 session needed 2-3 days apart
Feels like an intensive workout
No downtime
Instant results but gets better after two to four weeks