Provide three¡¡éand five lead system with arrhythmia analysis function
Adopting digital filter technology
Selectable 50hz or 60hz band stop filter
500hz 7/12 lead synchronous sample and anylsis
Character classification up to tweel sort, and 3 channel st segment monitoring
Advanced dsp algorithm monishes the influence of motion artifact All digital-signal processing improves accuracy of low perfusion Small size easy to be assem ble A wealth of experience in r&d, with perfect quality in the measurement precision
1. Adopting digital filter technology 2. Selectable 50hz or 60hz band stop filter 3. 500hz¡¡é7 lead synchronous sample and anlysis consumption and safely insulation 7. 5v ttl communication 8. 2-channel temperature detect , and two sort of sensor model 9. Detecting respiration by impedance between ra-ll
Measurement accuracy reaches medical grade Test speed is 30s Weak signal test (cufflink simulator test) is 20% Blood pressure measuring range 40 ~ 255mmhg Pulse rate 30bpm-~ 240bpm Resistantof occasional interference movement, support serial, support the hibernation feature
Features: 1.English menu display 2.Lead off/on signal by indicator light 3.Selectable multi-recording modes:3 channels,3 channels + rhythm 60 sec compressible: select simultaneously acquisition of 12-lead ECG signals 4.Automatic diagnosis and analysis 5.Save the half record paper and the half record time 6.The body check mode can record the patient ECG 15 seconds/each 7.Thermal printer (dot array),40 dot/mm,precise waveform 8.Rechargable battery pack 9.Hidden handle. Specifications: Acquisition mode: simultaneous 12 leads Operating mode: auto/manual Recording format: auto/manual/simultaneously 60 sec compressible LCD display: operation mode/ Status, HR Input Condition: against defibrillation Input impedance: >50MQ Patient Leakage Current: 3.2 s CMRR: > 100dB Filter:50Hz or 60 Hz (-20dB) prift(0.5Hz-3dB) Sensitivity Option: Auto,2.5,5,10,20,40mm/mv=2% Resist to polarization voltage:=500mV Electrical noise level:
Features: 1.English menu display; 2.Lead off/on signal by indicator light; 3.Selectable multi-recording modes:single channel, 2 channels,2 channels + rhythm; 60 sec compressible: select simultaneously acquisition of 12-lead ECG signals; 4.Save the half record paper and the half record time; 5.The body check mode can record the patient ECG 15 seconds/each; 6.Thermal printer (dot array),40 dot/mm,precise waveform; 7.Rechargable battery pack; 8.Hidden handle. Specifications: Lead: Standard 12 leads Acquisition mode: simultaneous 12 leads Operating mode: auto/manual Recording format: auto/manual/simultaneously 60 sec compressible LCD display: operation mode/ Status,HR Input Condition: against defibrillation Input impedance: >50MQ Patient Leakage Current: 3.2 s CMRR: > 100dB Filter:50Hz or 60 Hz (-20dB) prift(0.5Hz-3dB) Sensitivity Option: Auto,2.5,5,10,20,40mm/ mv=2% Resist to polarization voltage:=500mV Electrical noise level:
Ecg workstation gl8000 Specification: 1. Sample rate: 1000Hz, simultaneous 12 leads recording 2. Resolution:12bit 3. Power: 5.0V (DC) 4. Patient Insulation: 4000V AC 5. Defibrillation Protection: Built-in box 6. Digital resolution: 2 V 7. Frequency response: 0.05-250 Hz 8. Common mode rejection: >90dB 9. Input impedance: >10M 10. Time constant: í¦3.2 s 11. Max electrode potential: í+300mV DC 12. Dynamic range: í+10mV 13. Isolate voltage: 4000V 14. Current leak:
GE Healthcare MAC 500 ECG / EKG Machine with rolling cart Main Mac 5500 HD ECG Console CAM HD ECG Acquisition Module Rolling Cart Power Cord
Supplier: Nibp module, ECG module, digital SPO2 module ECG machine, patient monitor, mobile BP monitor, accessories of patient monitor
Supplier: ECG machine, ECG module, NIBP midule, SPO2 module, smart blood pressure device, patient monitor, gel warmer