Please click here to check who's online and chat with them.

Centrifuges: Genuis 6K-C

Supplier From China
Aug-18-10

AC frequency conversion motor, high precision, small volume, low noise

Blue backlit LCD display: speed, centrifugal time remaining, temperature in centrifuge chamber, accumulated running time, fault

Fixed-speed time function: running time begin with its setting speed

Electronic lock device to achieve the best operating performance

Touch keyboard, friendly user interface, easy to operate

Air-cooled centrifuge, effectively reduce the temperature rising in the centrifugal process

Automatic balancing, no need to trim out

Electronic imbalance monitoring and protection

Withí¦shortí¦instantaneous centrifugal function

Widely used in the field of pharmacy, biological production, blood center, scientific research institutions and so on

Vacutainer cover automatically taken off


Max. speed 6000 rpm
Max. RCF 5241 í-g
Max. capacity 32í-15ml
Time range 0-9h59min
Speed precision í+50rpm
Dimensions 54í-45í-37cm
Weight without rotor 42 kg
Noise í_58dBú¿Aú¬
Power 220v/50Hz 400w

No. Rotor model Capacity (ml) Max speed(rpm) Max RCF(í-g)
1 Fixed angle 12í-15 6000 5241
2 Swing out 4í-50 5000 4704
3 Swing out 8í-50 4000 3010
4 Swing out 4í-100 4000 3010
5 Swing out 24í-20 4000 3010
6 Swing out 32í-15 4000 3010
7 Swing out 4í-96MTP 4000 2616


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Centrifuges: Genuis 6K-C

GOLD Member
Dec-19-24
 
Refrigerated Brushless centrifuge with head 1.5 ml.Microprocessor based 128x64 Graphic lcd display, Temp -20 to ambient, Lid lock, Drive controlled, RPM 16000, Timer in built 99: 99, Heavy body vibration free.

Max. Speed : 20000 r.p.m.
* Max. RCF : 23000xg
* Timer : 0-99 min.
* Motor : Brushless Motor
* Temp. Range : From room temperature- to Minus 20�°C
* Temp. Accuracy : �±2�°C
* Power : AC 220V 50 Hz 20A
* Weight : 55� kg. approx.
* Dimension : L-25â?? x W-20â?? x H-14â?? approx

Special Feature :
* Low Sound
*Fitted with vacuum legs for better griping on table.
* Vibration free
* C.F.C. Free refrigeration
* Kirloskar compressor
VERIFIED
Oct-25-23
 
The BOD (Biochemical Oxygen Demand) Incubator is a crucial medical equipment used in hospitals for environmental and medical research. This specialized incubator maintains a stable temperature, typically 20�°C, 27�°C, or 37�°C, providing an ideal environment for biological sample incubation and testing. It features precise digital controls and uniform temperature distribution to ensure accurate and reproducible results. The interior is spacious, accommodating various sample sizes and containers. With energy-efficient design and robust construction, it's reliable for long-term operation. Hospitals rely on BOD incubators for critical applications, including wastewater analysis, microbiological studies, and medical research, ensuring the highest standards of accuracy and consistency.
Jan-13-11
 
We are the biggest manufacture of colored borosilicate glass rod&tubing in China ,we are also the exclusive manufacture of colored borosilicate glass rod&tubing since 2002.
Main composition:
a) SiO2: 80 ¦0.5%
b) B2O3: 13 ¦0.2%
c) Al2O3: 2.4 ¦0.2%
d) Na2O (+K2O): 4.3 ¦0.2%
Chemical properties:
a) Coefficient of mean linear thermal expansion :
(20/300 ¦C):3.3¦0.1 (10-6K-1)
b) Transformation temperature: 525¦15¦C
c) Working point: 1,260 ¦20¦C
d) Softening point: 820 ¦10¦C
e) Density at 20¦C: 2.23g/cm¦
f) Hydrolytic resistance at 98¦C: ISO719-HGB1
g) Hydrolytic resistance at 121¦C: ISO720-HGA1
h) Acid resistance class: ISO1776-1
i) Alkali resistance class: ISO695-A2

We now can produce 11 colors: red, opaque black, opaque white, pink, purple, green, yellow, amber, dark blue, light blue and transparent black. Test shows they contain no heavy metal elements.

The size we can do : OD: 3.5ù300mm W.T:0.8ù12mm, length 3000mm.
OEM is welcomed.
Nov-08-21
 
GLUCOSE AND LACTATE DETERMINATION
LYBCON Vacutainer glucose tubes are available in Sodium Fluoride EDTA. Glucose values in unpreserved blood samples decrease quickly after collection as glucose is metabolised by the blood cells. The additives contained in LYBCON VacutaineFluoride/EDTA tubes will stop enzymatic activity at the glycolytic pathway.


HbA1c DETERMINATION
One advantage of the Fluoride/EDTA tube over the Fluoride Oxalate tube is that the marker HbA1c can be determined from the same tube, so no additional tube sample needs to be taken.


CENTRIFUGATION CONDITIONS
1300g for 10 minutes at 18-25 C


MIXING RECOMMENDATION
Fluoride tubes should be gently inverted 180 and back 8-10 times.


SPECIFICATION
Specimen: Plasma

Additive: Sodium Fluoride and K3/K2 EDTA

Cap color: Grey

Tube Size: 13x75mm

Draw Volume: 2.0mL

Max. draw volume Tolerance: �±10%
Mar-11-19
 
I. Application

1.1 Dust-proof test box is designed and manufactured according to GB4208-93 (equivalent to IEC60529-2001) "Shell Protection Grade (IP Code)" and is suitable for sand and dust test of electrical products with the first characteristic digits of 5 and 6 (IPX5 and IPX6).

1.2 The test chamber can provide non-laminar vertical circulating airflow of dust, which can be controlled regularly. It is equipped with a vacuum pump to pump air into the outer shell of the tested product, and it can adjust the pumping volume and pressure difference.In addition,the air temperature control device is installed in the chamber to ensure that the test is carried out under the standard environmental conditions.

1.3 According to the standard requirements, this test chamber adopts the artificial analogy dust environment to test the dust-proof ability of the tested products, and its specific requirements and eligibility criteria should be in accordance with GB4208-93 (IEC60529-2001) or product-related standards.


2. Structure and Material

Material: both inside and outside gallbladder adopt SUS high grade stainless steel plate door: tempered glass door.

Sample outlet: dust-proof socket

Controller: programmable controller (the controller has the following arbitrary setting control functions).

A. Dust blowing time (stop and blow) h/m/s adjustable

B. Cycle: arbitrary adjustable

C. Preset test time: 0s to 999h99m99s arbitrary adjustable

D. Power on: break through break

Metal screen size: nominal diameter 50 um, nominal distance between lines 75 um

Blower: all plastic centrifugal fan

Vacuum system: equipped with pressure gauge, air filter, pressure regulating triple parts, connecting pipe (vacuum pump with another, when ordering instructions)

Remarks: The test box can meet the requirements of protection grade test for household appliances, low-voltage appliances, automobile and motorcycle parts in GB2423, GB4706, GB4208, DIN.

The device can not meet the sand and dust test in GJB150.
Oct-25-22

Cell Culture Flask

$3.95
MOQ: Not Specified
Supplier From Shenzhen, Guangdong, China
 
Cell Factory System, Cell Roller Bottles, Efficiency Erlenmeyer Flask, Erlenmeyer Shake Flask, Cell Culture Flask, Multi-wells Cell Culture Plate, Cell Culture Dish, Micro Centrifuge Tube, Centrifuge Tube, Serological Pipette. With 1500 square meters in line with the GMP grade C automation workshop, is committed to become the international leading high-end biological materials supplier. It also has I S O9 0 0 1:1 3 4 8 5 quality management system certification. Looking forward to working with you hand in hand, mutual benefit and win-win!
Oct-24-16

15Ml & 50Ml Centrifuge Tube

$0.01 - $0.40
MOQ: Not Specified
 
Introduction and features

1.Material: PP

2.Brand: WHB

3.Sterilized by gamma irradiation

4.Available with 2 sizes of 15,50ml

5.Black or white silk screen scale, clear lines. Large white marking area.

6.Can be one-handed operation, easy-spin tube cover, good sealing.

7.The maximum can withstand 12000 xg centrifugal force

8.The temperature range is -80 ° C to 120 ° C

9.Products can be held for single or multi-tube packaging

10.Dnase/Rnase and pyrogen free
May-10-24
 
Advantages of PFA Test Tubes:

1.Excellent Chemical Resistance: PFA, also known as perfluoroalkoxy, is a fluoropolymer that exhibits superior resistance to almost all chemicals, including acids, bases, solvents, and oxidizing agents. This ensures that your samples and reactions remain unaffected and uncontaminated during experimentation.
2.High Temperature Tolerance: PFA test tubes can withstand extreme temperatures ranging from cryogenic to over 260�°C. This broad temperature range makes them suitable for a wide variety of applications, including high-temperature reactions and cryogenic storage.
Excellent Transparency: PFA test tubes offer excellent optical clarity, allowing for clear and undistorted observation of samples and reactions. This is crucial for accurate monitoring and analysis in laboratory experiments.
3.Low Adsorption Properties: PFA has low adsorption properties, minimizing the risk of sample loss or contamination due to adsorption on the tube walls. This ensures the integrity and purity of your samples.
4.Physical Stability: PFA test tubes are physically robust and stable, maintaining their structural integrity even under extreme conditions like high-speed centrifugation.
Applications of PFA Test Tubes:

1.Chemical Industry: In the chemical industry, PFA test tubes are widely used for storing and transporting various chemicals due to their excellent chemical resistance. They are especially suitable for handling corrosive and reactive chemicals.
2.Semiconductor Manufacturing: In the semiconductor industry, PFA test tubes are used for transporting high-purity chemicals and reagents. Their material does not release any impurities, ensuring the purity of the manufacturing environment.
3.Photovoltaic Industry: PFA test tubes are also used in the photovoltaic industry for handling strong acids, bases, and high-purity chemicals during the manufacturing process.
4.Biological and Pharmaceutical Industries: In the biological and pharmaceutical industries, PFA test tubes are used for storing and transporting biomedical samples, reagents, and drugs. Their chemical inertness ensures that the samples remain unaffected and uncontaminated.
5.Laboratory Applications: PFA test tubes are extensively used in laboratories for various scientific experiments, especially those requiring minimal interaction with chemicals. Their transparency, chemical resistance, and temperature tolerance make them ideal for accurate monitoring and analysis.
web: https//www.njbinglab.com/

Verification Status