Function brief
The use of micro-power consumption of the apparatus a high level of integration of high-speed embedded processors. The use of high-energy three 5 # alkaline dry batteries or 5 # rechargeable batteries , can be 0 ~ 4ma output current signal precision, 0 ~ 9999.9hz precision frequency signals can be output 24v dc power, to apply two-wire field devices; can accurate measurement of dc 0 ~ 24ma current signal and frequency signal. Widely used in valve positioned, transducer, digital display, etc. And the majority of manufacturers of industrial and mining enterprises, to replace imported high-precision portable signal generator.
Overview Smart temperature transmitter input is single or two loop thermal resistance or thermocouple signal, transmitter output single loop or dual loop current or voltage signal, between the input , output, and power supply to provide good electrical isolation. Without using external zero point and full range regulation resistance can be adjusted digital signal, the scene shows the two real-time nixietube controls. Main technical indicators: Input signal: thermal resistance.--pt100, cu100, cu50, ba1, ba2 Thermocouple.--k, e, s, b, j, r, n, t Output signal:4í½20ma, 0í½10ma, 0í½5v, 1í½5v Type:single-input single-output, single-input, dual-output, dual-input dual-output Precision:0.5úÑ Temperature drift:0.00151%fs/íµ Power supply:24vdc Assemble way:din rail mount, 35mm rail size Terminal block .
ZJHP pneumatic film single-seat control valve is composed of multi-spring pneumatic diaphragm actuator and low-flow resistance small single-seat control valve body. Pneumatic single-seat control valve has the advantages of compact structure, light weight, sensitive action, small pressure drop loss, large valve capacity, accurate flow characteristics and convenient maintenance. It can be used in demanding working conditions. The multi-spring actuator is low in height, light in weight and easy to install. The pneumatic single seat control valve is equipped with a valve positioner to convert the current signal into a corresponding linear displacement, and automatically controls the opening of the regulating valve to achieve continuous adjustment of the process parameters such as pressure, flow, temperature and liquid level of the fluid in the pipeline. Pneumatic film single seat control valve is widely used in precise control of gas, liquid, steam and other media, especially suitable for work situations that allow small pressure difference and allow small leakage. The pneumatic diaphragm single seat control valve is stable in operation with reliable operating characteristics, small valve seat leakage, precise flow characteristics, and wide adjustable range. It will surely achieve high quality control effects in a wide range of applications with its unique advantages
ZJHP pneumatic film single-seat control valve is composed of multi-spring pneumatic diaphragm actuator and low-flow resistance small single-seat control valve body. Pneumatic single-seat control valve has the advantages of compact structure, light weight, sensitive action, small pressure drop loss, large valve capacity, accurate flow characteristics and convenient maintenance. It can be used in demanding working conditions. The multi-spring actuator is low in height, light in weight and easy to install. The pneumatic single seat control valve is equipped with a valve positioner to convert the current signal into a corresponding linear displacement, and automatically controls the opening of the regulating valve to achieve continuous adjustment of the process parameters such as pressure, flow, temperature and liquid level of the fluid in the pipeline. Pneumatic film single seat control valve is widely used in precise control of gas, liquid, steam and other media, especially suitable for work situations that allow small pressure difference and allow small leakage. The pneumatic diaphragm single seat control valve is stable in operation with reliable operating characteristics, small valve seat leakage, precise flow characteristics, and wide adjustable range. It will surely achieve high quality control effects in a wide range of applications with its unique advantages
HIC series smart valve positioner contains several kinds of specifications such as HIC11, HIC12, HIC08.It uses two-wire system transmission (The power source 4í½20mA simulating signal simultaneously transmits on two lines ). The psitioner and the actuator constitute a close loop control circuit. In this control circuit, the valve position feedback single as an variable which compared with rated signal in microprocessor and the D-value between them sends out different length of pulse through the delivery outlet of the main control panel to control the output pressure of the I/P change unit, thereby the positioner drive the control valve to act. (Refer to Fig.1) The pneumatic control valve with HIC smart valve positioner can overcome the friction force and unbalanced force of the valve plug well and enhance reaction speed of the control valve to rapid and precision localization, especially for vibration frequent places. It can replace conventional explosion-proof current-to-pneumatic valve positioner. The purchaser can monitor the valve position information through the feedback current and regulate or set the controlling parameter of the positioner with axial magnet or upper monitor at any moment. The purchasers only need to reset the relative parameter of the valve positioner and avoid changing the control valve because of the control system variation, so it is widely used in automatic control system such as petroleum, chemical industrial, electric power, metallurgy and light industrial, etc. TECHNICAL PARAMETER í± Input signalú¦4í½20mA analog signals í± Input loading voltageú¦7Víó9Vú¿With communicationú¬ í± Air supply pressureú¦0.16MPaí½0.6MPa í± intrinsic errorú¦í+1.0% í± Hysteresisú¦1.0% í± Dead bandú¦0.1%ú¿Min.ú¬ í± Functionú¦Self-diagnostics, configuration, travel characteristic correction, HART communication and so on í± Air consumptionú¦í_4.0Nl/min í± Strokeú¦10í½100mmú¿Turn angle 60ípí½90ípú¬ í± Conditions of working atmosphereú¦ a.Ambient temperatureú¦-40í½+80ípCú¼Explosion ¿Cproof typeú¦-40í½+60ípC b.Ambient humidityú¦5%í½95%ú+ c.Ambient atmosphereú¦86í½106kPaú+ d.There is no corrosive gas in ambient air. í± Power supplyú¦24V.DC í± Explosive-proof signú¦Ex dIICT6íóEx iaIICT6 í± Explosive-proof gradeú¦Factory Explosive-proof í± Enclosure classificationú¦IP65.
Short Description: The magneto-strictive level gauge is mainly used for continuous measurement of liquid level and liquid interface. Applications include: petroleum, chemical raw material storage, industrial processes, biochemistry, pharmaceuticals, food and beverage, tank management and gas station underground inventory, liquid level industrial metering and control, ship (dock), dam water level, reservoir water level monitoring and sewage treatment. The structural part of the magneto-strictive liquid level sensor is composed of a stainless steel tube (measuring probe), a magnetostrictive wire (waveguide wire), a movable float (with a permanent magnet inside), and a precision detecting circuit. When the sensor is operating, the circuit portion will excite a pulsed current on the waveguide wire that will generate a pulsed electromagnetic field around the waveguide wire as it propagates along the waveguide wire. A float is arranged outside the sensor probe, and the float can move up and down along the probe as the liquid level changes. There is a set of permanent magnetic rings inside the float. When the pulsed current magnetic field meets the magnetic ring magnetic field generated by the float, the magnetic field around the float changes so that the waveguide wire made of magnetostrictive material generates a torsional wave pulse at the position where the float is located,this pulse is transmitted back along the waveguide wire at a fixed speed and detected by the detection mechanism. By measuring the time difference between the pulse current and the torsional wave, the position of the float, that is, the position of the liquid surface, can be accurately determined Product features 1)Contact measurement 2)High precision, high stability, high reliability Long service life 4)Multiple signal output options 5)Reverse polarity protection 6)Lightning protection, anti-radio frequency interference 7)Compact structure and strong environmental adaptability 8)No need for periodic calibration and maintenance 9)Measure liquid level of tank with or without pressure 10)Isolated explosion-proof type (optional) 11)Easy installation Technical parameter: Output formï¼? 4ï½?20mAã??0ï½?5Vã??0ï½?10Vã??±5Vã??±10Vã??RS-485( varies from model to model) Linear errorï¼? superior to ±0.05%FSï¼?Sensors with a range of less than 300 mm has an error of less than 150 μm Repeaditityï¼? Superior to ±0.002%FS Output temperature driftï¼? 50ppm/ Product power consumptionï¼? â?¤50mA Output rippleï¼? â?¤20mV Load capacityï¼?4ï½?20mA outputï¼? Load capacityâ?¤500Ω ï¼? 0ï½?5Vï¼?0ï½?10V outputï¼?Controller loadâ?¥5KΩ Measuring probe materialï¼? 0Cr18Ni9Tiã??1Cr18Ni9Ti Electronic warehouse casing materialï¼?1Cr18Ni9Ti or aluminium die casting
Short Description: The magneto-strictive level gauge is mainly used for continuous measurement of liquid level and liquid interface. Applications include: petroleum, chemical raw material storage, industrial processes, biochemistry, pharmaceuticals, food and beverage, tank management and gas station underground inventory, liquid level industrial metering and control, ship (dock), dam water level, reservoir water level monitoring and sewage treatment. The structural part of the magneto-strictive liquid level sensor is composed of a stainless steel tube (measuring probe), a magnetostrictive wire (waveguide wire), a movable float (with a permanent magnet inside), and a precision detecting circuit. When the sensor is operating, the circuit portion will excite a pulsed current on the waveguide wire that will generate a pulsed electromagnetic field around the waveguide wire as it propagates along the waveguide wire. A float is arranged outside the sensor probe, and the float can move up and down along the probe as the liquid level changes. There is a set of permanent magnetic rings inside the float. When the pulsed current magnetic field meets the magnetic ring magnetic field generated by the float, the magnetic field around the float changes so that the waveguide wire made of magnetostrictive material generates a torsional wave pulse at the position where the float is located,this pulse is transmitted back along the waveguide wire at a fixed speed and detected by the detection mechanism. By measuring the time difference between the pulse current and the torsional wave, the position of the float, that is, the position of the liquid surface, can be accurately determined. Product features 1)Contact measurement 2)High precision, high stability, high reliability Long service life 4)Multiple signal output options 5)Reverse polarity protection 6)Lightning protection, anti-radio frequency interference 7)Compact structure and strong environmental adaptability 8)No need for periodic calibration and maintenance 9)Measure liquid level of tank with or without pressure 10)Isolated explosion-proof type (optional) 11)Easy installation Technical parameter: Output formï¼? 4ï½?20mAã??0ï½?5Vã??0ï½?10Vã??±5Vã??±10Vã??RS-485( varies from model to model) Linear errorï¼? superior to ±0.05%FSï¼?Sensors with a range of less than 300 mm has an error of less than 150 μm Repeaditityï¼? Superior to ±0.002%FS Output temperature driftï¼? 50ppm/ Product power consumptionï¼? â?¤50mA Output rippleï¼? â?¤20mV Load capacityï¼?4ï½?20mA outputï¼? Load capacityâ?¤500Ω ï¼? 0ï½?5Vï¼?0ï½?10V outputï¼?Controller loadâ?¥5KΩ Measuring probe materialï¼? 0Cr18Ni9Tiã??1Cr18Ni9Ti Electronic warehouse casing materialï¼?1Cr18Ni9Ti or aluminium die casting
The magneto-strictive level gauge is mainly used for continuous measurement of liquid level and liquid interface. Applications include: petroleum, chemical raw material storage, industrial processes, biochemistry, pharmaceuticals, food and beverage, tank management and gas station underground inventory, liquid level industrial metering and control, ship (dock), dam water level, reservoir water level monitoring and sewage treatment. When the sensor is operating, the circuit portion will excite a pulsed current on the waveguide wire that will generate a pulsed electromagnetic field around the waveguide wire as it propagates along the waveguide wire. A float is arranged outside the sensor probe, and the float can move up and down along the probe as the liquid level changes. There is a set of permanent magnetic rings inside the float. When the pulsed current magnetic field meets the magnetic ring magnetic field generated by the float, the magnetic field around the float changes so that the waveguide wire made of magnetostrictive material generates a torsional wave pulse at the position where the float is located,this pulse is transmitted back along the waveguide wire at a fixed speed and detected by the detection mechanism. By measuring the time difference between the pulse current and the torsional wave, the position of the float, that is, the position of the liquid surface, can be accurately determined. Product features 1)Contact measurement 2)High precision, high stability, high reliability Long service life 4)Multiple signal output options 5)Reverse polarity protection 6)Lightning protection, anti-radio frequency interference 7)Compact structure and strong environmental adaptability 8)No need for periodic calibration and maintenance 9)Measure liquid level of tank with or without pressure 10)Isolated explosion-proof type (optional) 11)Easy installation Technical parameter: Output formï¼? 4ï½?20mAã??0ï½?5Vã??0ï½?10Vã??±5Vã??±10Vã??RS-485( varies from model to model) Linear errorï¼? superior to ±0.05%FSï¼?Sensors with a range of less than 300 mm has an error of less than 150 μm Repeaditityï¼? Superior to ±0.002%FS Output temperature driftï¼? 50ppm/ Product power consumptionï¼? â?¤50mA Output rippleï¼? â?¤20mV Load capacityï¼?4ï½?20mA outputï¼? Load capacityâ?¤500Ω ï¼? 0ï½?5Vï¼?0ï½?10V outputï¼?Controller loadâ?¥5KΩ Measuring probe materialï¼? 0Cr18Ni9Tiã??1Cr18Ni9Ti Electronic warehouse casing materialï¼?1Cr18Ni9Ti or aluminium die casting Lead wire wayï¼? a.Shielded cable connection, default length 2m (can be customized according to user requirements) b.Aviation plug connection c.Terminal block connection Explosion typeï¼? ExiaIIBT4ã??ExdIICT5(Depending on the model) IP gradeï¼?IP65 Installationï¼?thread mountingã??flange mountingã??Positioning ring installationã??Suspension installation or user-specific customization (depending on model)
Name: High Temperature Saving Energy Gate Valve Special Features: The valve is welded in high strength heat-resistant steel, stainless steel and fine carbon steel. It is high-temperature resistance, high in strength, effective, endurance, handy to operate, definite direction, easy to maintenance and long life. High pressure cooling air device cools the disc and ensures its rigidity and non-distortion. The valve has two driving mode: integer and part. The integer driving device is fixed on the undercarriage. Part driving device canâ??t be controlled and can be installed refer to the userâ??s demand. Driving type is windlass elevating (open-close signal), electric actuator elevating (4ï½?20mA current signal), electric hydraulic, electric draw stem elevating (open-close signal). Suitable temperature: 350, Suitable medium: High temperature gas including Smoke, air, gas with powder, etc.
Special Features: The valve is welded in stainless steel and fine carbon steel, having double layers keeping temperature lining made in fire material. It also has the features of resistant to the high temperature, efficient in saving thermal energy, impact structure, easy to open and close and handy to operate. The valve's driving mode is part. Part driving device cannot be controlled and can be installed refer to the user's demand. Driving type is windlass elevating (open-close signal), electric actuator elevating (4~20mA current signal), electric hydraulic, electric draw stem elevating (open-close signal). Suitable temperature: 700, Suitable medium: High temperature gas including Smoke, air, gas with powder, etc