Please click here to check who's online and chat with them.

Portable Three Phase Energy Meter Test Bench

Supplier From China
Feb-20-23

The GF302D3 portable three phase energy meter test bench consists of an integrated three phase 120A current source and 600V voltage source and a class 0.02 three phase electronic reference standard meter.
The energy meter test bench is particularly designed for analysis of complete metering installations and local mains conditions. The meter test bench offers high functionality combined with an excellent menu guided operation via built-in thirty keys and colored 7 touch LCD-display. It can auto & manual test all kinds of energy meter error. Using on site or in the laboratory. It can preset a variety of test schemes for testing energy meter.

Price and Minimum Quantity

Price: $49565
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Portable Three Phase Energy Meter Test Bench

May-17-22
 
The GF302D3 portable three phase energy meter test bench consists of an integrated three phase 120A current source and 600V voltage source and a class 0.02 three phase electronic reference standard meter.
The energy meter test bench is particularly designed for analysis of complete metering installations and local mains conditions. The meter test bench offers high functionality combined with an excellent menu guided operation via built-in thirty keys and colored 7" touch LCD-display. It can auto & manual test all kinds of energy meter error. Using on site or in the laboratory. It can preset a variety of test schemes for testing energy meter.
May-23-14
 
1.Starting test and creeping test

2.Measuring the different constant meters synchronously.

3.With the protect function of overload, short voltage circuit and open current circuit.

4.The testing software with friendly windows 2000 and xp interface, include functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test.

5.The stored testing data can be transferred to multi-format for other program using
Apr-01-22
 
The GF302D1 three phase portable energy meter test equipment consists of an integrated three phase current source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display. Voltage & current harmonics output from 2 to 63 times. This model portable meter test equipment can be programmable by PC, automatic generation of energy meter error test report.
Feb-20-23
 
GF102 series portable single phase energy meter test bench used to test 1pc or 3pcs single phase energy meter or AC meter at same time. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output from 120A/600V. Widely used in lab and field, and then as single phase standard source. It is suite for electricity meter manufacturing enterprises, scientific research institutes, metrological service institutions, electric power companies etc.
Jul-14-11
 
Overview:

The RT6303B Multi-function Three Phase Energy Meter Test Instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis, digital frequency modulation, digital amplitude modulation, digital phase-shifting, pulse width modulation and so on to bring you such important features as high reliability and good load characteristics. Its more humane and intelligent meter calibration software makes it possible for an ordinary, heavy and boring calibration to be carried out more easily and efficiently.

Technical Parameters:
1. Accuracy class: 0.1/0.05
2. Reference standard energy meter: Three phase wide-measurement range standard energy meter, Accuracy class:0.1/0.05
3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range, adjustable phase by phase
4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase
5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase
6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz
7. Output waveform distortion: Both voltage and current<0.5%
8. Output voltage, current and power stability:<0.05%(180s)
9. Output capacity(per phase): Current:650VA(120A); Voltage:300VA(16 meter testing positions)If necessary, the maximum load can be extended to Current:1,500VA and Voltage:800VA
10. Load characteristics: Resistive, inductive and capacitive(less than 4uF)
11. Harmonic wave output:2-21st sub-harmonic wave, content<40%;3rd,5th and 7th sub-harmonic waves are superposed, content<10% each;Control of conduction angle(odd sub-harmonic wave);Control of wave group(sub-harmonic wave)
12. Starting up current: Minimum 0.3 mA, Accuracy:5%,Starting power: Accuracy:5%
13. Tests: Demand test; Frequency impact test; Voltage impact test; Second pulse clock precision test; GPS clock synchronization; Constant calibration; Combined error test; Various register checking;RS485 communication interface test
14. Energy meter testing positions:16/32(standard);3 to 40 meter testing positions also available
15. Testing functions: Accuracy testing, Creep testing(no load testing),Starting up testing, Harmonic testing, Repeatability testing, Influencing testing, Dial testing and etc
16. Power supply: AC 3*220/380V¡À10%,50Hz(customer define);Max. power consumption:2000VA(16 meter test positions).

Dimension:
16 Meter testing positions(1 rack): 2200*700*1920mm
32 Meter testing positions(2racks): 2200*700*1920mm
Cabinet: 600*800*1920mm.
May-23-14
 
Snt 1100 single phase meter test bench is widely used in power utilities,¡émeter manufacturer,¡émeasurement/quality test lab and other enterprises to test single phase energy meter.
Jan-08-14
 
Features:

1. Check the error of active and reactive of watt-hour meter at the same time, and meanwhile check the error of main and secondary meter in the same circuit.

2. Display the electrical constants such as: voltage, current, power, power factor, phase and frequency and etc.

3. Measure ct ratio, wave form display.

4. Measure 2-51 voltage and current harmonics.

5. Judge wrong wiring.

6. Measure the baud rate for multi-function energy meter and meter number reading.

¦ct secondary loading function.

8. Automatically correct the clamp error.
Jul-14-11
 
Overview:

The RT6303-S Three Phase Energy Meter Test Instrument(Split Type) adopts internationally advanced new-generation digital power source technologt,integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way.The Three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis,digital frequency modulation,digital amplitude modulation,digital phase-shifting,pulse width modulation and so on to bring you such important features as high reliability and good load characteristics.Its more humane and intelligent meter calibration software makes it possible for an ordinary,heavy and boring calibration to be carried out more easily and efficiently.

Technical Parameters:
1. Accuracy class: 0.1/0.05
2. Reference standard energy meter: Three phase wide-measurement range standard energy meter,Accuracy class:0.1/0.05
3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range,adjustable phase by phase
4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase
5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase
6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz
7. Output waveform distortion:Both voltage and current<0.5%
8. Output voltage,current and power stability:<0.05%(180s)
9. Output capacity(per phase): Current:650VA(120A); Voltage:300VA(16 meter testing positions). If necessary,the maximum load can be extended to Current:1,200VA and Voltage:800VA
10. Load characteristics:Resistive,inductive and capacitive(less than 4uF)
11. Harmonic wave output:2-21st sub-harmonic wave,content<40%; 3rd,5th and 7th sub-harmonic waves are superposed,content<10% each;Control of wave group(sub-harmonic wave)
12. Energy meter testing positions:16/32(standard);3~40 meter testing positions also available
13. Testing functions:Accuracy testing,Creep testing(no load testing),Starting up testing,Harmonic testing,Repeatability testing, Influencing testing,Dial testing and etc.
14. Power supply: AC 3*220/380V¡À10%,50Hz(customer define);Max. power consumption:2000VA(16 meter test positions).

Dimension:
16 meter testing positions(1 rack): 2200*700*1920mm
32 meter testing positions(2 racks): 2200*700*1920mm each
Cabinet: 600*800*1920mm.
GOLD Member
VERIFIED
Aug-08-08
Supplier From Shanghai, China, China

Verification Status