Especially developed for indication and
supervision of the three-phase circuit,
replaces an analogical ammeter, reducing
installation manpower and optimizing the
used one of spaces in the panel.
Ideal for protection of three-phase
networks is monitored and generally to
own alarm superior and inferior. Protection
of the parameters of programming by
password.
Especially developed for indication and supervision of the three-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the single-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the single-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the single-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the single-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password. Specifications Current inputs (TRMS) Communication (Option) CT primary 10 000 A Link RS485 CT secondary 1 and 5 A Type 2 ... 3 wires half duplex Sampling Rate 2 per sec Protocol Modbus RTU mode Resolution 0.001 to 1, depending on the range MODBUS speed 4800/9600bauds Burden < 0.5VA, < 0.2VA in 20A Analog Outputs (Option) Auxiliary power supply Number of outputs 1 channel AC voltage DC/AC 85~265 ± 30 % Type Isolated Frequency 50 / 60 Hz Range 0 / 4 ... 20 mA or 0-5V Consumption < 10 VA Maximum current 30 mA Front panel Alarm Outputs (Option) Display Type Red LED Super Bright Display Number of relays 1 channel Maximum Display 9999 Counts Type Passive nodes Polarity Indication "-" is indicated for negative input(option) Weight Case / Housing Material Approximate 250~400g Installation Panel mounting Environment Terminal Block Thermoplastic with Tin Plated Brass Terminal Calibration 27°C ± 5°C Dielectric Strength Operation 0 to 50°C, RH < 70% 2.5 kV at 50Hz for 1 min Storage -10 to 60°C, RH < 70%
Especially developed for indication and supervision of the three-phase circuit. Provide three-phase active power, reactive power, power factor measurement and display, can expand the measurement range, replaces old analogical meter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the three-phase circuit, replaces an analogical voltmeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.