GFUVE 2-63th THD class 0.5S Modbus RS485 LCD display AC power quality analyzer meter
FU2200A digital Ethernet power meter with data logger is a three-phase multifunction power and energy meter manufactured by GFUVE. It provides excellent value for monitoring power and energy management systems. It may be used as data gathering devices for intelligent power distribution or plant automation systems. All monitored data is available via a standard digital RS485 communication port, which is based on the Modbus RTU protocol.
FU2200A Ethernet power meter has the PC software and the data logger function, which can set by end users from 1min to 60min intervals to record. You can read the data through a PC. Also, you can share the data in the Internet LAN. By the way, it can measure the harmonics. Back of power meter FU2200A with Etherne
Product description Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system. When it is interfered or contaminated, grid power quality can t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country. 3 phase handheld power quality analyzer Technical index 1. Input characteristics
Description Power Recording Analyzer is designed for power signal record. The power generator test items are integrated at the tester. With those test items users can make motor Power generator No load test, Short circuit test, Motor excitation step response test, motor excitatory de excitation test, motor load rejection test and grid synchronous connection test and also on Technique index There are 12channels voltage current sample. The analog range include 10V10V, 200V 200V, 400V 400V and 20mA 20mA. Users can switch the input range from software. Also there is one channel 100mV 100mV which allow the input signal less than 10V. The voltage and current input range assured errors are as follow 400V 400V assured error less than 0.5V 200V 200V assured error less than 0.2V 10V 10V assured error less than 0.01V 20mA 20mA assured error less than 0.02m 100mV 100mV assured error less than 0.2mV There are 12 channel wet contacts binary signal input. The valid and allowed input voltage is DC12-200V. There are 3 channel relay contacts output. The maximum capacity for the contacts is AC220V 1A. There are 2 USB port used for data export and mouse keyboard input The LCD is 12.1 inches touch pad input mode. Make the human interface more simple. The saved space in the tester is 32G for standard configuration Input resistances for different channels are as follow 10V 10V Range Input resistance is 820K 200V 200V Range Input resistance is 820K 400V 400V Range Input resistance is 820K 20mA 20mA Range Input resistance is 820K 100mV 100mV Range Input resistance is 10M Power supply AC 220V 10 45Hz-65Hz
Description Power Recording Analyzer is designed for power signal record. The power generator test items are integrated at the tester. With those test items users can make motor (Power generator) No-load test, Short circuit test, Motor excitation step response test, motor excitatory de-excitation test, motor load rejection test and grid synchronous connection test and also on Technique index ~200V, -400V~400V and -20mA~20mA. Users can switch the input range from software. Also there is one channel -100mV~100mV which allow the input signal less than 10V. 2. The voltage and current input range assured errors are as follow: -400V~ 400V assured error less than 0.5V -200V~ 200V assured error less than 0.2V -10V~ 10V assured error less than 0.01V -20mA~ 20mA assured error less than 0.02mA -100mV~ 100mV assured error less than 0.2mV 3. There are 12 channel wet contacts binary signal input. The valid and allowed input voltage is DC12-200V. 4. There are 3 channel relay contacts output. The maximum capacity for the contacts is AC220V/1A. 5. There are 2 USB port used for data export and mouse/keyboard input 6. The LCD is 12.1 inches touch pad input mode. Make the human interface more simple. 7. The saved space in the tester is 32G for standard configuration 8. Input resistances for different channels are as follow: -10V~10V Range Input resistance is 820K -200V~200V Range Input resistance is 820K -400V~400V Range Input resistance is 820K -20mA~20mA Range Input resistance is 820K -100mV~100mV Range Input resistance is 10M 9. Power supply AC 220V 10% 45Hz-65Hz
Product Introduction SMG7000 Handheld Power Quality Analyzer Input Characteristics 1. Voltage measuring range: 0~400V auto. 2. Current measurement range 3. Clamp transformers (three): 5A/25A (standard) 100A/500A (optional) 400A/2000A (optional) 4. Phase angle measurement range: 0~359.99 �°. 5. Frequency range: 45~55Hz. 6. Voltage number of channels: three channels (UA UB and UC). 7. Current number of channels: three channels (IA IB IC). 8.Maximum number of harmonic analysis: 63 times. 9. Intervals of 1 minute maximum storage period: 18 months
SMG7000 Handheld Power Quality Analyzer Input Characteristics 1. Voltage measuring range: 0~400V auto. 2. Current measurement range 3. Clamp transformers (three): 5A/25A (standard) 100A/500A (optional) 400A/2000A (optional) 4. Phase angle measurement range: 0~359.99 �°. 5. Frequency range: 45~55Hz. 6. Voltage number of channels: three channels (UA UB and UC). 7. Current number of channels: three channels (IA IB IC). 8.Maximum number of harmonic analysis: 63 times. 9. Intervals of 1 minute maximum storage period: 18 months
Product description Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system. When it is interfered or contaminated, grid power quality canâ??t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country. 3 phase handheld power quality analyzer Technical index 1. Input characteristics Voltage measuring range: 0 200V 800V, automatic cutting gear. Current measurement range Clamp transformers (three types): 5A / 25A (standard) 100A / 500A (optional) 400A / 2000A (optional) Phase angle measuring range: 0 ~ 359.99 . Frequency measurement range: 45 ~ 55Hz. Voltage channels: three-channel (UAã??UBã??UC). Current channels: three-channel (IAã??IBã??IC). Maximum harmonic analysis times: 63 times. Maximum continuous storage period in 1 minute interval: 18 months. 2. Accuracy
Supplier: Gas analyzers, dew point meters, water analyzers, caaqms, dissolved gas analyzers, transmitter
Services: Transportation, shipping etc
Product description Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the and in the laboratory. Technical index Portable Three-phase Standard Meter Electrical parameters Accuracy class 0.05% Voltage supply Range 5V-480V Error Display range 5.000000V-480.0000V Harmonic 2nd-63st Range 1mA-120A Error Display range 1.000000mA-120.0000A Active power 0.05% (0.01A-0.2A) Reactive power Apparent power Active energy
Product description Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the eld and in the laboratory. Technical index Portable Three-phase Standard Meter Electrical parameters Accuracy class 0.05% Voltage supply Range 5V-480V Error Display range 5.000000V-480.0000V Harmonic 2nd-63st Range 1mA-120A Error Display range 1.000000mA-120.0000A Active power