The purpose of the isolating amplifier RISH Ducer TV 808 is to electrically insulate input and output signals, respectively to amplify and / or change the signal level or type (current or voltage) of the input signals. The amplifier fulfils all the important requirements and regulations concerning electromagnetic compatibility EMC and safety (IEC 1010 resp. EN 61 010). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 9001. The device has two channels and provides two independent isolating amplifiers in an extremely small space. The user has a wide choice of input and output ranges and can set the desired one with the aid of soldered jumpers (coarse adjustment) and potentiometers (fine adjustment)
Easy location orientation of the measured values due to the built-in camera which generates a visible image with an overlay of the thermal image
Easy documentation and fast exchange of data using the Bosch Measuring Master app
More flexibility due to Dual Power Source: Can be used with 12 V-LI-ion battery or with standard alkaline batteries
Infrared sensor with 19,200 measuring pixels (160 x 120) for detailed, informative thermal imaging
Easy to use with clear, easy-to-read thermal images for an effortless introduction into the world of thermography
Identify overheated components in electrical installations immediately making system testing, inspections and maintenance efficient
ML14xx is Multiload Monitor with 12 single phase load or 4 three phase load option. It measures important electrical parameters of multiple loads simultaneously in a single unit, eliminating the need and cost of multiple panel meters. It provides quick, easy and error free current connections with plug and play connectors. It measures real time electrical parameters like Active / Reactive / Apparent energy and power, current, THD, demand, max demand for each load. The instrument has 4 configurable relay outputs, which can be used for Limit / Pulse / Residual Current / 3Phase Load Health Monitoring / Tariff / RTC / Timer tripping or alarms. This instrument communicates with either MODBUS or Ethernet connection
2in1 meters measure two different ranges of frequencies in the range of 45 to 450Hz. For maximum accuracy, the essential measuring range is obtained by suppressing unwanted frequency span. The meter is housed in UL94V-0 approved polycarbonate case and can be mounted in Mosaic mounting.
2 in 1 meters measure average values of DC Voltage or DC Current. Any two different parameters can be measured in one case with this meter. It is housed in UL 94 V-0 approved polycarbonate case and can be mounted in Mosaic mounting (cascading).
Analog Meters measure AC/DC Voltage or Current and frequency. These meters are installed on 35mm Din rail, the mounting width is 45mm and it is housed in UL 94 V-0 approved polycarbonate case and can be mounted in Mosaic mounting (cascading).
Features:
Wide range of system current Ratings
Hinged terminal cover
Various mounting options like DIN rail mounting, Wall mounting
Terminal with self lifting screw with dual connection facility giving access from both sides of transformers
300 Kg / Day
Brand AGRI
Automatic Grade Semi-Automatic
Design Standard
Power Consumption 2.5 Unit/hr
Voltage 380V
Power 3 hp 3 phase motor
Owing to the wide experience in this domain, we are instrumental in offering Coconut Oil Extraction Machine to our clients.
for the measurement of electrical variables in heavy current power system RISH Ducer M40 (Fig. 1) is a programmable transducer with a RS 485 bus interface (MODBUS ). It supervises several variables of an electrical power system simultaneously and generates 4 proportional analogue output signals. The RS 485 interface enables the user to determine the number of variables to be supervised (up to the maximum available). The levels of all internal counters that have been configured (max. 4) can also viewed. Provision is made for programming the RISH Ducer M40 via the bus. A standard EIA 485 interface can be used, but there is no dummy load resistor for the bus. The transducers are also equipped with an RS 232 serial interface to which a PC with the corresponding software can be connected for programming or accessing and executing useful ancillary functions. This interface is needed for bus operation to configure the device address, the Baud rate and possibly increasing the telegram waiting time (if the master is too slow) defined in the MODBUS protocol. The usual methods of connection, the types of measured variables, their ratings, the transfer characteristic for each output and the type of internal energy metering are the main parameters that can be programmed. The ancillary functions include a power system check, provision for displaying the measured variably on a PC monitor, the simulation of the outputs for test purposes and a facility for printing nameplates. The transducer fulfils all the essential requirements and regulations concerning electromagnetic compatibility(EMC) and safety (IEC 1010 resp. EN 61 010). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 9001. nSimultaneous measurement of several variables of a heavycurrent power system / Full supervision of an asymmetrically loaded four-wire power system, rated current 1 to 6 A, rated voltage 57 to 400 V (phase to neutral) or 100 to 693 V (phase-ton phase) nFor all heavy-current power system variables n4 analogue outputs nInput voltage up to 693 V (phase-to-phase) nUniversal analogue outputs (programmable) High accuracy: U/I 0.2% and P 0.25% (under reference nconditions) 4 integrated energy meters, storage every each 203 s, storage nfor: 20 years Windows software with password protection for programming, data analysis, power system status simulation, acquisition of nmeter data and making settings DC-,AC-power pack with wide power supply tolerance / nuniversal Provision for either snapping the transducer onto top-hat rails or securing it with screws to a wall or panel
The laser measures from Bosch are ideal for every professional user who wants to take exact measurThe laser measures from Bosch are ideal for every professional user who wants to take exact measurements quickly: Equipped with state-of-the-art laser technology, Bosch measures deliver results with maximum precision and reliability.eThe laser measures from Bosch are ideal for every professional user who wants to take exact measurements quickly: Equipped with state-of-the-art laser technology, Bosch measures deliver results with maximum precision and reliability.ments quickly: Equipped with state-of-the-art laser technology, Bosch measures deliver results with maximum precision and reliability.
The compact Multi Line Laser for all indoor applications
One horizontal and 2 vertical 360�° lines enable many new applications for simultaneous marking, alignment and levelling indoors
Self-levelling (4 in 4 sec), very precise (± 0.2 mm/m) and range of up to 80 m with receiver
Compact, easy-to-handle and extremely robust (IP54)
TEMPERATURE METERBosch GIS 500 Professional Temperature Meter
Type of Product: Thermo Detector
Laser diode*: Laser class 2, 635 nm
Power supply and runtime: 2 x 1.5V LR6 (AA) batteries 9h
Weight: 0.22kg
Measurement range: Surface temperature, -30 degC to +500 degC