1. Utilizing the American Copeland high-efficiency flexible jet booster, the unit has stable running performance and high heating efficiency, it has a special gas balance and oil balance design to ensure the stable operation of the unit.
2. The temperature difference between the inlet and outlet water of the unit is stable, the fluctuation range of the refrigerant pressure is small, the hot water is quickly prepared with small power consumption, the temperature of the outlet water is 55. High-efficiency casing heat exchanger with small volume, high heat exchanger efficiency, and long service life.
3. After the power is cut off, the unit will be automatically recorded tje current various working parameters. It is not necessary to reset the parameters when its restarted, and it will be working as usual, which is convenient and worry-free.
There are 4 models of the products. ENE-32DKCB/ ENE-95DKCB/ ENE-130DKCB/ ENE-160DKCB
Heating capacity(kW) 31.5
Input Power(kW 9.2
Protection level IPX4
Outlet water temperature() 40~60
Dimensins(mm) 1200*970*1420
Circulating water flow ratio(m/h) 8
Applicable ambient temperature range -25~45
Heating capacity(kW) 95
Input Power(kW27.6
Protection level IPX4
Outlet water temperature() 40~60
Dimensins(mm) 2400*1135*2150
Circulating water flow ratio(m/h) 18
Applicable ambient temperature range -25~45
Heating capacity(kW) 130
Input Power(kW38
Protection level IPX4
Outlet water temperature() 40~60
Dimensions(mm) 2400*1900*2150
Circulating water flow ratio(m/h) 20
Applicable ambient temperature range -25~45
Heating capacity(kW) 160
Input Power(kW47
Protection level IPX4
Outlet water temperature() 40~60
Dimensins(mm) 2400*2000*2420
Circulating water flow ratio(m/h) 24
Applicable ambient temperature range -25~45
1.High efficiency and energy saving: adopt an internationally famous brand compressor and heat pump special compressor, environmental protection refrigerant, high-efficiency heat exchanger, adhering to heat pump control technology, special high-temperature heating system. The system is more stable, with the high thermal efficiency of high-temperature drying (80-85â??), saving energy significantly, and the cost of producing heat is much lower than that of electric heating, gas, and fuel oil. 2.Easy to use: only power on can start the operation, no need for special room prevention equipment; Green environmental protection: high-temperature hot water can be used as a thermal medium to bake the required drying materials through heat pump drying equipment. The unit eliminates the pollution of waste gas and waste residue caused by combustion. Remarks: 1. All the above quotations are the EXW price with our standard packing. 2. Customized is available, samples can be provided. 3.Lead time: upon receipt of payment. 4. This quotation is valid within a month. Shipping method: UPS/FedEx/DHL/TNT/By Sea/By Air etc.
Model Number: Portable Air Conditioner ((WT-F26 gray) Power Type: DC Use: Room Condition: New After-sales Service Provided: None Warranty:1 year Type: PORTABLE Certification:CB, ce Cooling/Heating:Cooling Only Application:Car, Commercial, Garage, Hotel, Household, Outdoor, RV Power Source:Electric, usb Remote Control: Yes App-Controlled: Yes
1.Rated heating conditions A7/W35: outdoor air temp. 7 DB/6 WB, inlet water temp. 30, outlet water temp. 35 2.Rated cooling conditions A35W7: outdoor air temp. 35 DB/24 WB, inlet water temp. 12, outlet water temp. 3. Due to product improvement, the above data are subject to change without prior notice, please take the nameplate as standard.
* PHOSCAST Phoscast : Phosphate Bonded Castables * PURPOSE customers using FBC boilers (Particularly underbed feed FBC boilers) for the protection of inbed coils against erosion potential by applying highly abrasive resistant refractory on inbed coils above fuel feed system. BACKGROUND * Two of such actions are providing special alloy studs on inbed coils and applying highly abrasive resistant refractory on the outer bottom loops of inbed Coils which are above the fuel feed nozzles. * GANESHAS has taken number of approaches to identify the key factors affecting erosion rates with an objective to enhance the life of inbed tubes as well as implementing the corrective action to reduce the erosion rates. Phosphate coatings are often used to protect steel parts against rusting and other types of corrosion * Erosion of inbed coils in fluid bed combustor is unavoidable phenomenon however the rate of metal wastage and thus the life of tubes depends on various factors like ash & fuel properties, design of Combustor / feeding system, flue gas velocities operating conditions etc. It has been also observed that maximum erosion prone inbed coils are those which come above fuel feed nozzles and an area of approximately 1 to 1.5 mts around fuel feed systems are badly affected. APPLICATION Phoscast-90 XR can be applied by ramming with wooden mallet having adequately large head @" dia x 5" length x 10â?? Jong handle). The desired lining or repair thickness is built up in several courses while ramming the mass to uniform thickness. Phoscast refractory should never be trawled to obtain smooth surface; ramming only should finish surface. Any excess mass is to be sliced off with trowel edge and then finished by ramming again for bed coil. Tube application of AFBC boiler, the material pasty mass should be finger pressed into the studs of the tube with maximum force. Finish should be given by pressing the hand palm against material applied, using surgical type thin rubber hand gloves.
Supplier: Air conditioner spare parts , compressors , gases and motors.
Buyer: Air conditioner spare parts , compressors , gases and motors.