Model: CD4(G)
Description: CD4(G) Multi-parameter Gas Detector
MA: MFA160132
KA: KFA160028
ExibI: 116.4340
Patent No. ZL 2015 2 0976912.2
Introduction:
1. Detect the gas concentration of CO, NO2, SO2 and H2S.
2. Reliable performance, portable, high luminance LCD display.
3. Concentration, time, electric quantity can be displayed on screen.
4. Detector will cause luminescence and noise if gas concentration is over standard.
5. Applicable for STEL and TWA detection, atmosphere, environment, landfill, petrochemical, metallurgy, mine, seal space entrance, dangerous materials, industrial paint, leakage, IAQ detection.
Technology parameters:
1. CO (10-6CO)
Measuring range Accuracy
0~20 ± 2
20~100 ± 4
100~500 Measured value ± 5%
500~1000 Measured value ± 6%
2. NO2(10-6NO2)
Measuring range Accuracy
0~20 ± 1
3. SO2(10-6SO2)
Measuring range Accuracy
0~20 ± 1
4. H2S(10-6H2S)
Measuring range Accuracy
0~50 ± 3
50~100 Truth value ± 10%
5. Response time: T
IMR IX616 Multi Gas Detector * Continuous detection of O2, CO, H2S, CH4 * High / low alarms * High quality sensor that detects gases via diffusion * Durable case suitable for any environment * Measuring memory * Data transfer to PC * Includes four sensors IX616 Multi Gas Detector Specifications * CH4 Detecting Range: 0~100%LEL * H2S Detecting Range: 0~100ppm * CODetecting Range: 0~1000ppm * O2 Detecting Range: 0~30%vol * Accuracy: ±5% FS * Response time: T90 < 30s * Working environment: -20 to 50'C, 95% RH (no dew) * Protection grade: IP65
Capillary cable is composed of a submersible power cable and a continuous stainless steel composite pipe. Diluent chemicals are injected into oil and gas Wells through composite pipes to make heavy oil Wells easier to recover. The injection of descaling chemical agent can effectively remove the oil pipe scaling. Sensors can be connected to collect downhole temperature, pressure, liquid level and other well parameters; The valve can be connected to the downhole safety valve and the wireline packer vent valve, and controlled on and off by surface pressure.
This is a DC voltage and current transducer. The operating principle is Photoelectric Isolation/Treble isolation. It can measure DC voltage and DC current at the same time, and has two channels of standard signal. The input, output and power supply are isolated from each other. It's featured in high accuracy, high isolation, low drift and so on. This product can be used in railway, industry control, and other fields. Rated input: 0~1-500V; 0~0.5-5A Output signal: 0~5V DC (Vz); 0~20mA (Iz); 4~20mA (Iy);0~10V DC (Vd);OC frequency output:(0-5KHz/0-10KHz) optional Power supply: 12V;15V; 24V; optional Accuracy: 0.5% optional Output ripple: 10mV Isolation: 2500V DC Humidity: â?¤95%(no dew) Load resistance: Voltage Output >2kohm; Current Outputâ?¤250ohm Temperature drift: 500/ppm Response time: â?¤200ms Operating temperature:: -10~+60 Quiescent power consumptio:
"Semiconductor sensor Operating voltage: 85-265V AC; Alarm output: Sound& LED Flash alarm; Alarm level: 10% ±5% LEL. MCU processing adopted,SMT adopted,good stability Malfunction auto-check indicator Dimension: 118.5*82*43mm . Execute criterion:GB15322;EN50194;UL1484 Drivable accessaries: electromagnetic valve and exhaust fan; Can make 9V chargable back up battery "
"AV voltage: AC 90V-240V 50-60Hz Battery voltage: 9V rechargeable battery (optional) Working temperature: 0°C-50°C Warm-up time: about 180S Environment: 10%-95% Sound level: 85dB / m Alarm density: 2500PPM (±1500PPM) Size: 112 Ã? 73 Ã? 42MM"
Portable Gas Detectors can detect VOC, Toxic, Combustible & Oxygen types of gases which are used for personal safety. Portable Gas Detection System will detect the concentration of gases in confined spaces, sewer manholes, wastewater treatment plants, pharmaceutical industries, fertilizer industry, and many other applications with the display of gas concentration on the LCD. Portable Gas Monitors are a must for people entering hazardous areas. These detectors have the feature of secure handling and programming with three keys and power supply with rechargeable batteries. They have a password-protected function menu, plug-in sensor, and built-in audio buzzer. These Portable Gas Detectors also have optional data logging facilities with 50000 records, which are visible in ASCII format while downloading to PC via USB interface.
Model: CJL100/1000 Description: CJL100/1000 CH4 and H2S Gas Detector MA: MFA150187 KA: KFA150019 ExibI: 320150857 Patent No. ZL 2015 2 0975096.3 Introduction: 1. Detect the gas concentration of CH4, H2S. It will cause alarm when concentration is over standard. 2. Alarm is luminescence and voice. Technology parameters: 1. CH4 (%LEL) Measuring range Intrinsic error 0~20 ± 2 20~60 Truth value ± 10% 60~100 ± 6 2. H2S (ppm) Measuring range Intrinsic error 0~49 ± 3 50~100 Truth value ± 10% >100~1000 Truth value ± 15% 3. Response time: Tâ?¤30s 4. Battery: Rechargeable lithium battery. 5. Working time: Tâ?¥ 12 hours 6. Recharge time: Tâ?¤ 4 hours 7. Data record: data storage, 3000 sets data. 8. Levels of protection: IP65 9. Alarm type: noise, LED light, vibration.
"AV voltage: AC 90V-240V 50-60Hz Battery voltage: 9V rechargeable battery (optional) Working temperature: 0°C-50°C Warm-up time: about 180S Environmental humility: 10%-95% Sound level: 85dB / m Alarm density: 2500PPM (±1500PPM) Alarm: vocals and LCD Size: 112 Ã? 73 Ã? 42MM"
"AV voltage: AC 90V-240V 50-60Hz Battery voltage: 9V rechargeable battery (optional) Working temperature: 0°C-50°C Warm-up time: about 180S Ambient humidity: 10%-95% Sound level: 85dB / m Alarm concentration display Carbon monoxide gas: 100PPM~999MM (±50PPM) Combustible gas: 0.25%~2% LEL (2,5500PPM~20,000PPM±1,500PPM) Alarm: vocal alert and siren alarm"