IMR IX616 Multi Gas Detector
* Continuous detection of O2, CO, H2S, CH4
* High / low alarms
* High quality sensor that detects gases via diffusion
* Durable case suitable for any environment
* Measuring memory
* Data transfer to PC
* Includes four sensors
IX616 Multi Gas Detector Specifications
* CH4 Detecting Range: 0~100%LEL
* H2S Detecting Range: 0~100ppm
* CODetecting Range: 0~1000ppm
* O2 Detecting Range: 0~30%vol
* Accuracy: ±5% FS
* Response time: T90 < 30s
* Working environment: -20 to 50'C, 95% RH (no dew)
* Protection grade: IP65
"Semiconductor sensor Operating voltage: 85-265V AC; Alarm output: Sound& LED Flash alarm; Alarm level: 10% ±5% LEL. MCU processing adopted,SMT adopted,good stability Malfunction auto-check indicator Dimension: 118.5*82*43mm . Execute criterion:GB15322;EN50194;UL1484 Drivable accessaries: electromagnetic valve and exhaust fan; Can make 9V chargable back up battery "
"AV voltage: AC 90V-240V 50-60Hz Battery voltage: 9V rechargeable battery (optional) Working temperature: 0°C-50°C Warm-up time: about 180S Environment: 10%-95% Sound level: 85dB / m Alarm density: 2500PPM (±1500PPM) Size: 112 Ã? 73 Ã? 42MM"
Portable Gas Detectors can detect VOC, Toxic, Combustible & Oxygen types of gases which are used for personal safety. Portable Gas Detection System will detect the concentration of gases in confined spaces, sewer manholes, wastewater treatment plants, pharmaceutical industries, fertilizer industry, and many other applications with the display of gas concentration on the LCD. Portable Gas Monitors are a must for people entering hazardous areas. These detectors have the feature of secure handling and programming with three keys and power supply with rechargeable batteries. They have a password-protected function menu, plug-in sensor, and built-in audio buzzer. These Portable Gas Detectors also have optional data logging facilities with 50000 records, which are visible in ASCII format while downloading to PC via USB interface.
"AV voltage: AC 90V-240V 50-60Hz Battery voltage: 9V rechargeable battery (optional) Working temperature: 0°C-50°C Warm-up time: about 180S Environmental humility: 10%-95% Sound level: 85dB / m Alarm density: 2500PPM (±1500PPM) Alarm: vocals and LCD Size: 112 Ã? 73 Ã? 42MM"
"AV voltage: AC 90V-240V 50-60Hz Battery voltage: 9V rechargeable battery (optional) Working temperature: 0°C-50°C Warm-up time: about 180S Ambient humidity: 10%-95% Sound level: 85dB / m Alarm concentration display Carbon monoxide gas: 100PPM~999MM (±50PPM) Combustible gas: 0.25%~2% LEL (2,5500PPM~20,000PPM±1,500PPM) Alarm: vocal alert and siren alarm"
Introduction: QB2000 gas alarm control panel is a multi-point monitoring of the latest design with simple operation and it combines with any gas detectors to form an industrial gas detection system. This control panel embeds micro processor as control unit, when the detected gas density in the air reaches or exceeds the pre-set value, the controller will give out audio-visual alarm immediately to remind you take safety precautions and alert the corresponding valve, exhauster and other equipment to avoid explosion, fire, toxic gases to protect the safety of life and treasures. This system applies to metallurgy, petrol, petrifaction, chemistry, light industry, coking, municipal administration, gas, pharmaceutical, sewage dealing and many other special industry and field that need proofing for fire, explosion, and toxic gas leakage. Characteristics: High-performance sensor 128*64 dot matrix big screen liquid digital display With English Instruction Manual and pictures easy to operate Various gas detector together to fix Display the detected gas density in distance High sensitivity, and quick response Automatic compensation for temperature -drift and time drift The up and low alarm points of each channels can be set separately 8 channel 4-20mA signals output RS485, RS232 communication port can upload data to computers & 4 Relay output and the relay setting is programmable
4-20mA analog output for direct communication to DCS system or RS485 ModBus RTU output optiona. Relay output for connecting external device LCD display screen(LED display screen optional) Advantage: Sensor module(block) design on -spot replacement s and automatically distinguish sensor fault and current display fault simultaneously. When the sensor out of service or the sensor fails, the user can check and solve the problem by replacing spare modules,saving the time and cost. The LCD display and LED display module can be interchanged, supporting swift hot swap,support plug and play functionality. The sensor module and the connection interface in the detector have jack and plug prevent improper insertion.Just spin and press the plug gently,the plug can be inserted the jack. The sensor module of the detector can be replaced by the same type module and the different gas sensor module,and different range sensor module. The detector can distinguish and operation itself. Whatever the sensor module is chosen to replace the original one, there is no need to re-calibrate it. The detector automatically distinguishes the sensor module, reads the ex-factory calibration value and the related setting value and operates detecting when the self-inspection is done. Password verification for repeat operation, avoid fault operations. -40~+70 following compensation for accurate detecting. Twp grade visual alarms on-site and Relay (connected with audible/visual alarms or drive exhaust device). User-selectable alarm setpoint(s).
Product Introduction: The handheld SF6 gas leak detector is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users, and at the same time apply our rich technology and experience to this product, allowing users to enjoy an excellent price-performance ratio. The high-tech central microprocessor unit is the core of the qualitative leak detector for sulfur hexafluoride gas. Its digital signal processing capabilities can better manage circuits and process detection signals. Due to the use of a large number of integrated circuits, the number of components in the circuit is reduced by 40%, which greatly improves reliability and efficiency. The microprocessor can monitor the probe and battery voltage at a rate of 4000 times per second. Even the smallest signal can be captured. It can work stably and reliably in any environment. The SF6 gas qualitative leak detector has added some convenient functions. Seven-level sensitivity, the sensitivity is increased by 64 times. The three-color LED gradually indicates the degree of leakage in a large range, and is also used to display the sensitivity level and battery power. Touch the keyboard to perform all operations. The avant-garde slender shape design greatly facilitates the user's use and maintenance. It is very convenient to use the indicator light in the direct range. Technical parameters: Power supply 3V DC 2 alkaline batteries Maximum sensitivity R12 R22 R134a approved (14g/year) Limiting sensitivity about 20 hours Probe life About 20 hours Operating temperature Battery life about 30 hours under normal use Working way continuous unlimited Response time instantaneous Reset time 1 SEC Warm-up time about 2 seconds Weight 560g
Product Introduction: The handheld SF6 gas leak detector is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users, and at the same time apply our rich technology and experience to this product, allowing users to enjoy an excellent price-performance ratio. The high-tech central microprocessor unit is the core of the qualitative leak detector for sulfur hexafluoride gas. Its digital signal processing capabilities can better manage circuits and process detection signals. Due to the use of a large number of integrated circuits, the number of components in the circuit is reduced by 40%, which greatly improves reliability and efficiency. The microprocessor can monitor the probe and battery voltage at a rate of 4000 times per second. Even the smallest signal can be captured. It can work stably and reliably in any environment. The SF6 gas qualitative leak detector has added some convenient functions. Seven-level sensitivity, the sensitivity is increased by 64 times. The three-color LED gradually indicates the degree of leakage in a large range, and is also used to display the sensitivity level and battery power. Touch the keyboard to perform all operations. The avant-garde slender shape design greatly facilitates the user's use and maintenance. It is very convenient to use the indicator light in the direct range. Technical parameters: Power supply 3V DC 2 alkaline batteries Maximum sensitivity R12 R22 R134a approved (14g/year) Limiting sensitivity about 20 hours Probe life About 20 hours Operating temperature 0â??-52â?? Battery life about 30 hours under normal use Working way continuous unlimited Response time instantaneous Reset time 1 SEC Warm-up time about 2 seconds Weight 560g Size 229 65 65mm3 Probe length 35.5cm