Panoramic Dental X-ray machine YSX1005
Specialty:
High voltage Generator, minimum radiation for patient.
Patient positioning with chin rest and reference with bit
Available for adult, children, left, right or frontal partial
views and upper jaw joints, lower jawbone.
Technology Parameters:
1. IEC classification: Class I, type BF
2. Power supply:230V 50/60HZ 10A
3. Mains resistance: ú+ 20ohm at 20V
4. X-Ray generator: Multi-pulse at 10kHz
5. Anodic Voltage:60-86KV Constant Potential .
NW:200KG
GW:250KG.
Mobile High frequency C-arm X-ray Machine YSX0701
C-arm X-ray Machine Introduction:
The clinical applications of this C-arm X-ray machine include orthopedics (arthroplasty, joint nailing, joint fluoroscopy, restoration and fixation for bone injury in emergency), radiology (abdominal organ angiography, gastrointestinal fluoroscopy), gynecology (uterus angiography), urology (kidney and bladder angiography), surgery (pacemaker implantation, peripheral vascular examination, etc.) and so on.
Key Features of C-arm X-ray Machine:
1. Adopts the true digital high frequency host, gets the clearest and richest image with minimum dose, greatly reduces the potential harm of x-ray to clinicians and patients.
2. The unique double displays make operation intuitive, easy and reliable.
3. The vertical and horizontal movements and rotation of C-arm are all electric maneuvered.
4. Micro-computer based controller features with failure self-diagnostic function, easy maintenance.
5. Digital interfaces optionally equip with picture collection & storage workstation, directly upgrade the digital image system, to provide a short cut for your heavy file management.
Upgraded Digital Image System of C-arm X-ray Machine:
1. Up to 100,000 static images stored in hard disk
2. Multi-image simultaneously display
3. Image processing functions: rotation, overturn lightness and contrast adjustment
4. Diagnostic report by laser printer
Technical Data:
Generator power/Frequency 3.5kw/40KHz 5kw/40KHz
Radiography KV 40-110KV 40-120KV
Radiography mA 30-70mA 24-70mA
Fluoroscopy KV 40-110KV 40-120KV
Fluoroscopy mA 0.1-5mA 0.1-5mA
Pulse fluoroscopy 0.1-8mA 0.1-8mA
Focus size 0.6í-1.5mm 0.3í-0.6mm
Stationary anode Rotation anode
Anode heat capacity 30KJ(40kHU) 150KJ(200kHU)
Heat capacity of 500KJ(667kHU) 600KJ(800kHU)
Collimator Iris, auto-tracking, variable visual field, double leaf
Focus-to-image intensifier distance(SID) 1000mm 1000mm
C-arm depth 730mm 730mm
C-arm open 815mm 815mm
C-arm arc glide with full balance 115íp 115íp
C-arm rotation(motored) í+180íp í+180íp
Upward and downward movement(motored) 400mm 400mm
Forward and backward movement(motored) 200mm 200mm
Horizontal swing angle í+12.5íp í+12.5íp
Image intensifier 9" metal screen intensifier
Camera High speed CCD camera
Monitor 14" high resolution monitor
Panel Two operation panels, automatic display error codes
Image memory Store 8 images, freeze the last image, multilevel denoise, double displays in one screen
Supply power 220V,50Hz,20A
Power capacitor 4KVA .
GW:300KG
NW:240KG.
600mA TV Remote Control Medical Diagnostic X-Ray Radiography Machine YSX0603
1. Microcomputer control x-ray radiography assembles: optional 600mA.
2. Total 432 storage combination controlled by element such as kV mA S is applied radiography for the following filed three body position, fat middle and thin body type, automatic detect and display cod of mistake in system, send warning signal, detect accuracy and maintain.
3. X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protectorate provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.
4. Bulb type over remote-controlled diagnostic table and image intensifier television system are installed. They realize not only bright operation, but also supply convenience for science resonator suffer are reduced. Specifications of automatic spot-film are abundant. There are also automatic collimators for users convenience.
5. Applied in all kinds of hospital for radiography such as general body, beam filtration, and chest.
Department
Technology parameters
High voltage generator control table and high voltage transform assemble
Fluoroscopy
Tube currency
0.3-5mA continuous currency
Tube voltage
50-110KV continuous voltage
Radiography
Tube currency
32-630mA shift
Tube voltage
45-125KV continuous voltage
Exposure time
0.01-6.3s 23 shift
Power
Voltage
380Ví+10%
Frequency
50Hzí+1Hz
Capacity
í¦50KVA
Inner resistance
í_0.3ª+
X-ray assembly
Focus
1í-1.2í-2 double focal
Rated rotate speed of anode
2800r/min
Changed beam limited device
Diagnosis table YS09D
Automatic, adjusted field of view
CS15Electro-motion diagnostic table
The table body rotation
"-15ípí½0ípí½+90íp"
Focus to film distance
1100í½1500mm,adjustable manual
360ípfoot board
The table to height
870mm
Stationary grid
Grid density
40L/cm
Grid ration
10:01
Focusing distance
120cm
Spot film device
Scope of moving
Longitudinal moving: 900mm;
Transverse moving: í+120mm
Specification of scope film
Full :8"í-10", 10"í-12", 11"í-14", 14"í-14"
Two: 8"í-10", 10"í-12"
Three:11"í-14", 14"í-14"
Four: 11"í-14", 14"í-14"
Medical television system
configuration
9ísx-ray image intensifier made by Toshiba, CCD camera,14ís high resolution monitor
14ísmonitor
resolution
Horizontal centerí¦1000 TV line
Gray scale
í¦10 grades
Video width
>12MHZ
Mode of scan
625 lines, 5 field, Interlaced scanning
Geometry distortion
<2%
SNR
í¦40db
Power supply
220V 50Hz AC
9ísx-ray image intensifier made by Toshiba
resolution
í¦46LP/mm
Conversion modulus
34cd/m2/ª¦GY/s
Contrast
10% area: 30:1, ª¦10mm area: 18:1
CCDJapan Camera
Specification
1/2ís, anti-halation, CCIR752í-586.
Option
CDG Multi function radiography table
Moving table
Lengthways
í+600mm
Electromagnetism locking
Across
í+120mm
íí
Mobile beam filtration grid
Grid density
28L/cm
Grid ratio
8:1
Focusing distance
100cm
Scope of moving
í¦600mm
Radiography item
5ísí-7ís, 8ísí-10ís, 10ísí-12ís, 11ísí-14ís, 12ísí-15ís, 14ísí-14ís, 14ísí-17ís
Distance from surface to film
75mm
Height of bed
700mm
Moving pillar
í+180íp,per 90íporientation, moving lengthways í¦1500mm
Bulb tube
Rotate the cross armí+180, ascend $ descend 1100mm
LSJ pillar radiography frame
The scope of ascend and descend
1450mm
The minimum distance from focal spot
380mm
Radiography item
8"í-10" 10"í-12" 11"í-14"12"í-15"14"í-14" 14"í-17"
Fixed beam filtration role
Grid density
40L/cm
Grid radio
10:1
Focal distance
180cm.
NW:256KG
GW:320KG.
High Frequency Mammography unit(tube import from other country) YSX0902
X-ray Generator
Generator Type:High Frequency Inverter 30-60kHz
Input Power: Single phase 220VAC, 50/60Hz
Radiographic Ratings:Large Focal Point 22-39KV/1-600mAs
Small Focal Point 22-39KV/1-100mAs
Power Rating:5.5kW
X-ray Tube
Model:IAE X-ray Tube
Anode rotation rate: 0000 rpm
Focal Spot Size: Dual Focus 0.1 / 0.3mm
Target Material:Molybdenum (Mo)
Port Material:Beryllium (Be)
Anode Heat Storage: 300KHU
Anode Cooling:Air cooling
Filtration: Mo(0.03mm),Al(0.5mm)
Radiographic Stand
C-ARM:Vertical Movement:60cm (70~130cm) Motorized
Rotations Deg:í+180íp Motorized (Deg.Data Display)
SID: 65cm
Cassette Image Receptor
Bucky Device:18í-24cm Bucky drive mechanism
Grid Ratio:5:1 ,30 Line/cm
Line Voltage
220V,Single phase
Weight
240kg
Comfortable Compression
When some degree of pressure is required for radiography, it allows you to presser the appropriate pressure(up to a maximum of 20kg)and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range.
Tissue Compression: Manual and Motorized (Max 20kg)
Compression Force and Thickness Data Display
Micro Control's Compression
Automatic Release
Intelligent Automatic Exposure Control(AEC)
With the Automatic Exposure Control system, it is possible to produce images with reliable intensity suitable for and film, screen, or method of radiography.
Furthermore, it greatly enhances the convenience of radiography by embedding the Full-AEC function which is capable of utilizing the Auto kV
Type:Solid-State Detector or PMT Detector
Microprocessor Control
AEC Mode:Full AEC(Auto kV)
Semi AEC (KV Select)
Manual (kV,mAs Select)
Density Adjustment:16 density steps.
GW:300kg
NW:240KG.
100mA mobile x-ray machine YSX0410
GENERAL
1. Used in ward and emergency treatment room for radiography.
2. Combined x-ray generator.
3. Single focus, bridge rectification.
4. It is precise safe, reliable and flexible.
5. Remote control device(control rangeí¦5m)is used.
Unit Configuration
Control table, HT generator unit, Ht cable, X-ray tube unit .
Main Characteristics
1. Single table and single tube.
2. Design according to the electric mechanism of middle-size machine ,The function is reasonable.
3. The high-tension system is of march-past structure. Equipped with afullwave rectification high-voltage generator and independent X-ray tube unit, with large output power and reliable and stable operation.
4. Supply voltage (V), roentgenoscopy, radiography (kv) and stepless adjust able.
5. Equipped with the manostat for filament of X-ray tube and the spacecharge compensator as to ensure the stable and accurate output.
6. Equipped with the capacity limitation and portection circuit and KV mA S interlock limitation and protection.
7. Adopt the digial circuit timer, grade according to R10 priority coefficient and can control time exactly.
8. Diagnostic table is of electric back rotation and is equipped with vibrating filter-ray device.
9. The spot film device of luminescent serene can hold the film jecket of various sizes and can make the photography of full-film and two sectional films separateiy.
10. The column has the bottom track only, which is easy while installation.
MIN TECHNICAL INDEXES
X-ray generator : Stationary anode, single focus and bridge silicon rectification.
The x-ray generator is an oil-immersed self-cooled unit.
Max rated capacity
Current
15mA
30mA
60mA
100mA
Voltage
90kvp
90kvp
90kvp
80kvp
Time
6.3s
6.3s
4.0s
3.2s
Power supply
Voltage
180-240V
Frequency
50Hz
Capacity
Not over than 7KVA
Intemal resistance
Not larger than 1ª+
Voltage adjustment range of x-ray tube
50-90KV
Range of the time
0.08-6.3s
Distance between the focus to the ground
700-1780mm
X-ray tube focus transverse rotation
í+60íp
Specification of x-ray tuble
Model XD42.9/100 fixed anode, single focus 1.8/4.3mm
Transport dimension(Lí-Wí-H)(mm)
1230í-900í-2050
Weight(kg)
Net:159/gross:256.
Transport dimension(Lí-Wí-H)(mm)
1230í-900í-2050
Net:159KG
Gross:256KG.