EAC 790
Engine: CUMMNS
Engine Model : KTA38-G1
Stand By kVA: 790
Stand By kW : 632
Prime kVA: 718
Prime kW : 574
Rated Current : 1033
Engine
- CUMMNS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMNS
Engine Model KTA38-G1
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 19
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 701 / 953
Prime Power Hp 634 / 862
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 158
Lt %75 LOAD 122
Lt %50 LOAD 86
Frequency Hz
Power kVA 550
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9200
Weight (Open) Kg 8050
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 17
Engine: PERK NS
Engine Model : 403A-15G1
Stand By kVA: 17
Stand By kW : 13,6
Prime kVA: 15,4
Prime kW : 12,3
Rated Current : 22,1
Engine
- PERK NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine PERKNS
Engine Model 403A-15G1
Number of Cylinders 3 Inline
Injection System InDirect
Compression Ratio 22.5:1
Bore 84
Strok 90
Displacement Lt 1,49
Air Intake Naturally Aspirated
Speed (RPM) 1500
Oil Capacity Lt 6
Standby Power kw / Hp 13,2 / 17,7
Prime Power Hp 12 / 16,1
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 6
Fuel Consumption (lt / h) Lt Full Load 3,9
Lt %75 LOAD 2,9
Lt %50 LOAD 2
Frequency Hz 50
Power kVA 15
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 545
Weight (Open) Kg 500
Width (Silent) Mm 950
Length (Silent) Mm 2000
Height (Silent) Mm 1200
Fuel Tank Capacity Lt 125
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 50
Engine: PERKNS
Engine Model : 1103A-33TG1
Stand By kVA: 50
Stand By kW : 40
Prime kVA: 45
Prime kW : 36
Rated Current : 65
Engine
- PERKNS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine PERKNS
Engine Model 1103A-33TG1
Number of Cylinders 3 Inline
Injection System Direct
Compression Ratio 17.3: 1
Bore 105
Strok 127
Displacement Lt 3,3
Air Intake Turbocharged
Speed (RPM) 1500
Oil Capacity Lt 7,9
Standby Power kw / Hp 45,6 / 61,6
Prime Power Hp 41,3 / 56
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 18
Fuel Consumption (lt / h) Lt Full Load 10,8
Lt %75 LOAD 8,2
Lt %50 LOAD 5,8
Frequency Hz
Power kVA 50
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 1100
Weight (Open) Kg 940
Width (Silent) Mm 950
Length (Silent) Mm 2300
Height (Silent) Mm 1400
Fuel Tank Capacity Lt 145
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 165
Engine:
Engine Model : 1106A-70TAG2
Stand By kVA: 165
Stand By kW : 132
Prime kVA: 150
Prime kW : 120
Rated Current : 216
Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine
Engine Model 1106A-70TAG2
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 18,2 : 1
Bore 105
Strok 135
Displacement Lt 135
Air Intake Turbocharged and Air Charge cooled
Speed (RPM) 1500
Oil Capacity Lt 18
Standby Power kw / Hp 149,1 / 202
Prime Power Hp 136 / 184
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 22
Fuel Consumption (lt / h) Lt Full Load 33,2
Lt %75 LOAD 24,5
Lt %50 LOAD 16,2
Frequency Hz
Power kVA 165
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 1950
Weight (Open) Kg 1710
Width (Silent) Mm 1000
Length (Silent) Mm 3150
Height (Silent) Mm 1700
Fuel Tank Capacity Lt 250
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 220
Engine:
Engine Model : 1106A-70TAG4
Stand By kVA: 220
Stand By kW : 176
Prime kVA: 200
Prime kW : 160
Rated Current : 288
Engine
heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine
Engine Model 1106A-70TAG4
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 16:01
Bore 105
Strok 135
Displacement Lt 7,01
Air Intake Turbocharged and air charge cooled
Speed (RPM) 1500
Oil Capacity Lt 18
Standby Power kw / Hp 196.3 / 265
Prime Power Hp 178.9 / 242
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 22
Fuel Consumption (lt / h) Lt Full Load 45,8
Lt %75 LOAD 34,7
Lt %50 LOAD 23,1
Frequency Hz
Power kVA 200
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
DIMENSIONS
Weight (Silent) Kg 2270
Weight (Open) Kg 1940
Width (Silent) Mm 1200
Length (Silent) Mm 3500
Height (Silent) Mm 1850
Fuel Tank Capacity Lt 360
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
FP 250
Engine
Engine Model : 1206A- E70TTAG2
Stand By kVA: 250
Stand By kW : 200
Prime kVA: 227
Prime kW : 182
Rated Current : 327
Engine
heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed
Alternat
IP 21-23 Protection Standard
H Insulation Class
50 Hz Frequency
4 pole brushless synchronous type alternator
Automatic Voltage Regulator (AVR)
400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
Convenient design for easy lifting and carrying
High standard sound proof canopy design
Modular design with easily removable nuts - bolts
Lockable doors
Transparent window for watching Control Panel
Electrostatic powder painted, providing protection against harsh weather conditions
Emergency STOP button
Fuel tank inside the chassis
Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine
Engine Model 1206A- E70TTAG2
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 15.08:1
Bore 105
Strok 135
Displacement Lt 7,01
Air Intake Turbocharged aftercooled
Speed (RPM) 1500
Oil Capacity Lt 16,5
Standby Power kw / Hp 226 / 303
Prime Power Hp 204 / 273
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 25
Fuel Consumption (lt / h) Lt Full Load 50,6
Lt %75 LOAD 37,9
Lt %50 LOAD 25,2
Frequency Hz
Power kVA 200
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 2550
Weight (Open) Kg 2120
Width (Silent) Mm 1300
Length (Silent) Mm 3900
Height (Silent) Mm 1980
Fuel Tank Capacity Lt 450
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 220
Engine: CUMM NS
Engine Model : 6CTAA8.3-G2
Stand By kVA: 220
Stand By kW : 176
Prime kVA: 200
Prime kW : 160
Rated Current : 288
Engine
- CUMM NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMNS
Engine Model 6CTAA8.3-G2
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 18.0:1
Bore 114
Strok 135
Displacement L 8,3
Air Intake Turbocharged Air Aftercooled
Speed (RPM) 1500
Oil Capacity L 23,8
Standby Power kw / Hp 203 / 272
Prime Power kw / Hp 183 / 245
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 12,3
Fuel Consumption (lt / h) L Full Load 45
L %75 LOAD 34
L %50 LOAD 23
Frequency Hz
Power kVA 220
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1
Insulation Class H
Protection Standard IP22 - IP23
Power Factor 0,8
Weight (Silent) Kg 2190
Weight (Open) Kg 1850
Width (Silent) Mm 1200
Length (Silent) Mm 3500
Height (Silent) Mm 1850
Fuel Tank Capacity L 360
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 825
Engine
Engine Model : KTA38-G2
Stand By kVA: 825
Stand By kW : 660
Prime kVA: 750
Prime kW : 600
Rated Current : 1080
Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine
Engine Model KTA38-G2
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 731 / 980
Prime Power Hp 664 / 890
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 167
Lt %75 LOAD 128
Lt %50 LOAD 90
Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9250
Weight (Open) Kg 8100
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 550
Engine: CUMMNS
Engine Model : KTA19-G3A
Stand By kVA: 550
Stand By kW : 440
Prime kVA: 500
Prime kW : 400
Rated Current : 720
Engine
- CUMMNS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMNS
Engine Model KTA19-G3A
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 13.9:1
Bore 159
Strok 159
Displacement L 19
Air Intake Turbocharged & Intercooled
Speed (RPM) 1500
Oil Capacity L 38
Standby Power kw / Hp 504 / 675
Prime Power kw / Hp 448 / 600
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 75
Fuel Consumption (lt / h) L Full Load 107
L %75 LOAD 82,3
L %50 LOAD 56,4
Frequency Hz
Power kVA 550
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 5085
Weight (Open) Kg 4410
Width (Silent) Mm 1900
Length (Silent) Mm 4800
Height (Silent) Mm 2400
Fuel Tank Capacity L 1450
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 650
Engine: CUMMNS
Engine Model : KTAA19-G6
Stand By kVA: 650
Stand By kW : 520
Prime kVA: 590
Prime kW : 472
Rated Current : 849
Engine
- CUMMNS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMNS
Engine Model KTAA19-G6
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 13.0:1
Bore 159
Strok 159
Displacement Lt 19
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 38
Standby Power kw / Hp 570 / 770
Prime Power Hp 518 / 700
Fuel Type Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 75
Fuel Consumption (lt / h) Lt Full Load 140
Lt %75 LOAD 104,9
Lt %50 LOAD 74,5
Frequency Hz
Power kVA 550
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 5190
Weight (Open) Kg 4510
Width (Silent) Mm 1900
Length (Silent) Mm 4800
Height (Silent) Mm 2400
Fuel Tank Capacity Lt 1450
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 690
Engine: CUMM NS
Engine Model : KTAA19-G6A
Stand By kVA: 690
Stand By kW : 552
Prime kVA: 630
Prime kW : 505
Rated Current : 910
Engine
- CUMM NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM NS
Engine Model KTAA19-G6A
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 13.0:1
Bore 159
Strok 159
Displacement L 19
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity L 38
Standby Power kw / Hp 610 / 825
Prime Power kw / Hp 554 / 750
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 75
Fuel Consumption (lt / h) L Full Load 148,3
L %75 LOAD 112,7
L %50 LOAD 76,4
Frequency Hz
Power kVA 550
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 5200
Weight (Open) Kg 4530
Width (Silent) Mm 1900
Length (Silent) Mm 4800
Height (Silent) Mm 2400
Fuel Tank Capacity L 1450
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 750
Engine: CUMM NS
Engine Model : QSK19-G11
Stand By kVA: 740
Stand By kW : 592
Prime kVA: 672
Prime kW : 538
Rated Current : 968
Engine
CUMM NS heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed
Alternat
IP 21-23 Protection Standard
H Insulation Class
50 Hz Frequency
4 pole brushless synchronous type alternator
Automatic Voltage Regulator (AVR)
400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
Convenient design for easy lifting and carrying
High standard sound proof canopy design
Modular design with easily removable nuts - bolts
Lockable doors
Transparent window for watching Control Panel
Electrostatic powder painted, providing protection against harsh weather conditions
Emergency STOP button
Fuel tank inside the chassis
Anti-vibration wedges (engine - chassis and chassis ground)
Optional
Thermal magnetic CB (for automatic models)
Super Silent Canopy
Mobile Generator Sets
Automatic fuel filling system
Synchronization panel
3 Pole and 4 Pole ATS (Automatic Transfer Switch)
Fuel Heater, Oil Heater
External fuel tank and automatic fuel filling system
Fuel - water separator filter
Remote monitoring and control system
Engine CUMM NS
Engine Model QSK19-G11
Number of Cylinders 6 - Inline
Injection System Direct
Compression Ratio 15.9 : 1
Bore 159
Strok 159
Displacement lt 19
Air Intake Turbo Aftercooler
Speed (RPM) 1500
Oil Capacity lt 80
Standby Power kW / Hp 667 / 907
Prime Power kW / Hp 606 / 827
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity lt 42
Fuel Consumption (lt / h) lt Full Load 135
lt %75 LOAD 103
lt %50 LOAD 69,5
Frequency Hz 50
Power kVA 740
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP21 - IP23
Power Factor 0,8
Weight (Silent) Kg 5750
Weight (Open) Kg 4900
Width (Silent) mm 1900
Length (Silent) mm 4800
Height (Silent) mm 2700
Fuel Tank Capacity lt 1350
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 33
Engine: PERKNS
Engine Model : 1103A-33G
Stand By kVA: 33
Stand By kW : 26,4
Prime kVA: 30
Prime kW : 24
Rated Current : 43,2
Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine PERKNS
Engine Model 1103A-33G
Number of Cylinders 3 Inline
Injection System Direct
Compression Ratio 19.25:1
Bore 105
Strok 127
Displacement Lt 3,3
Air Intake Naturally Aspirated
Speed (RPM) 1500
Oil Capacity Lt 8,3
Standby Power kw / Hp 30,4 / 41
Prime Power Hp 27,7 / 37,3
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 8
Fuel Consumption (lt / h) Lt Full Load 7,2
Lt %75 LOAD 5,6
Lt %50 LOAD 4
Frequency Hz
Power kVA 33
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 980
Weight (Open) Kg 825
Width (Silent) Mm 900
Length (Silent) Mm 2200
Height (Silent) Mm 1350
Fuel Tank Capacity Lt 135
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 70
Engine: PERK S
Engine Model : 1104A-44TG1
Stand By kVA: 70
Stand By kW : 56
Prime kVA: 64
Prime kW : 51
Rated Current : 92
Engine
heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed
Alternat
IP 21-23 Protection Standard
H Insulation Class
50 Hz Frequency
4 pole brushless synchronous type alternator
Automatic Voltage Regulator (AVR)
400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
Convenient design for easy lifting and carrying
High standard sound proof canopy design
Modular design with easily removable nuts - bolts
Lockable doors
Transparent window for watching Control Panel
Electrostatic powder painted, providing protection against harsh weather conditions
Emergency STOP button
Fuel tank inside the chassis
Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine
Engine Model 1104A-44TG1
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 17.25 : 1
Bore 105
Strok 127
Displacement Lt 4,4
Air Intake Turbocharged - Air to Air Cooled
Speed (RPM) 1500
Oil Capacity Lt 8
Standby Power kw / Hp 65,6 / 88,5
Prime Power Hp 59,6 / 80,5
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 13
Fuel Consumption (lt / h) Lt Full Load 14,6
Lt %75 LOAD 11
Lt %50 LOAD 8
Frequency Hz
Power kVA 79
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 1280
Weight (Open) Kg 1100
Width (Silent) Mm 1000
Length (Silent) Mm 2400
Height (Silent) Mm 1500
Fuel Tank Capacity Lt 180
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 150
Engine Model : 1106A-70TG1
Stand By kVA: 150
Stand By kW : 120
Prime kVA: 136
Prime kW : 110
Rated Current : 195
Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine Model 1106A-70TG1
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 18,2 : 1
Bore 105
Strok 135
Displacement Lt 7,01
Air Intake Turbocharged
Speed (RPM) 1500
Oil Capacity Lt 18
Standby Power kw / Hp 135,8 / 183,5
Prime Power Hp 122,7 / 166
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 22
Fuel Consumption (lt / h) Lt Full Load 30,1
Lt %75 LOAD 21,9
Lt %50 LOAD 15,2
Frequency Hz
Power kVA 150
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 1890
Weight (Open) Kg 1650
Width (Silent) Mm 1000
Length (Silent) Mm 3150
Height (Silent) Mm 1700
Fuel Tank Capacity Lt 250
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 110
Engine Model : 1104C-44TAG2
Stand By kVA: 110
Stand By kW : 88
Prime kVA: 100
Prime kW : 80
Rated Current : 144
Engine
heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine
Engine Model 1104C-44TAG2
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 18,2 : 1
Bore 105
Strok 127
Displacement Lt 4,4
Air Intake Turbocharged - Air to Air Cooled
Speed (RPM) 1500
Oil Capacity Lt 8
Standby Power kw / Hp 80.7 / 109
Prime Power Hp 73.4 / 99
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 13
Fuel Consumption (lt / h) Lt Full Load 22
Lt %75 LOAD 16,9
Lt %50 LOAD 11,1
Frequency Hz
Power kVA 110
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 1480
Weight (Open) Kg 1290
Width (Silent) Mm 1000
Length (Silent) Mm 2800
Height (Silent) Mm 1500
Fuel Tank Capacity Lt 210
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 200
Engine Model : 1106A-70TAG3
Stand By kVA: 200
Stand By kW : 160
Prime kVA: 182
Prime kW : 145
Rated Current : 262
Engine
heavy duty diesel engine
12V starter and charge alternator
Replaceable air, fuel and oil filters
Mechanical governor control
Tropical type radiator
Flexible fuel hose
Oil drain valve and extension hose
Industrial type silencer and steel compensator
Maintenance-free starter battery
Water jacket heater
1500 rpm engine speed
Alternat
IP 21-23 Protection Standard
H Insulation Class
50 Hz Frequency
4 pole brushless synchronous type alternator
Automatic Voltage Regulator (AVR)
400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
Convenient design for easy lifting and carrying
High standard sound proof canopy design
Modular design with easily removable nuts - bolts
Lockable doors
Transparent window for watching Control Panel
Electrostatic powder painted, providing protection against harsh weather conditions
Emergency STOP button
Fuel tank inside the chassis
Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine Model 1106A-70TAG3
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 16:01
Bore 105
Strok 135
Displacement Lt 7,01
Air Intake Turbocharged and air charge cooled
Speed (RPM) 1500
Oil Capacity Lt 16,5
Standby Power kw / Hp 180.2 / 243,5
Prime Power Hp 162.7 / 220
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 22
Fuel Consumption (lt / h) Lt Full Load 41,5
Lt %75 LOAD 31,8
Lt %50 LOAD 20,2
Frequency Hz
Power kVA 200
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 2190
Weight (Open) Kg 1850
Width (Silent) Mm 1200
Length (Silent) Mm 3500
Height (Silent) Mm 1850
Fuel Tank Capacity Lt 360
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
ENGINE
- RICARDO heavy duty diesel engine
- 12V / 24V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
-Water jacket heater
- 1500 rpm engine speed
ALTERNATOR
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
SOUND PROOF CANOPY AND CHASSIS
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection
against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â??
ground)
OPTIONAL
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
EA Genset supplies Cummins engine diesel generators sizes from 1 kVA to 3000 kVA Variety of Fuel Types
EA Genset supplies Perkins engine diesel generators sizes from 10 kVA to 2500 kVA Variety of Fuel Types
EA Genset supplies Sdec engine diesel generators sizes from 100 kVA to 1100 kVA Variety of Fuel Types
EA Genset supplies Lister Petter engine diesel generators sizes from 8 kVA to 30 kVA Variety of Fuel Types
EA Genset supplies Sdec Copy Sdec engine diesel generators sizes from 220 kVA to 890 kVA Variety of Fuel Types
EAR 77
Engine: RICARDO
Engine Model : D4105-IZLD
Stand By kVA: 77
Stand By kW : 61,6
Prime kVA: 70
Prime kW : 56
Rated Current : 100,8
Engine
- RICARDO heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternatir
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine RICARDO
Engine Model D4105-IZLD
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 17:01
Bore 105
Strok 115
Displacement L 3,93
Air Intake TURBO INTER - COOL.
Speed (RPM) 1500
Oil Capacity L 15
Standby Power kw / Hp 72,6 / 95,5
Prime Power kw / Hp 66 / 88,4
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 20
Fuel Consumption (lt / h) L Full Load 17,5
L %75 LOAD 15,2
L %50 LOAD 9
Frequency Hz
Power kVA 77
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP21 - IP23
Power Factor 0,8
Weight (Silent) Kg 1180
Weight (Open) Kg 990
Width (Silent) Mm 1000
Length (Silent) Mm 2400
Height (Silent) Mm 1500
Fuel Tank Capacity L 180
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading is not permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAR 125
Engine: RICARDO
Engine Model : R6105-ZLD
Stand By kVA: 125
Stand By kW : 100
Prime kVA: 113
Prime kW : 90
Rated Current : 162,72
Engine
- RICARDO heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine RICARDO
Engine Model R6105-ZLD
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 16:01
Bore 105
Strok 130
Displacement L 6,49
Air Intake Turbocharged
Speed (RPM) 1500
Oil Capacity L 13
Standby Power kw / Hp 110 / 147,45
Prime Power kw / Hp 100 / 134
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 23
Fuel Consumption (lt / h) L Full Load 25,6
L %75 LOAD 19,2
L %50 LOAD 12,8
Frequency Hz
Power kVA 125
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP21 - IP23
Power Factor 0,8
Weight (Silent) Kg 1540
Weight (Open) Kg 1290
Width (Silent) Mm 1000
Length (Silent) Mm 3150
Height (Silent) Mm 1700
Fuel Tank Capacity L 250
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 88
Engine: CUMMINS
Engine Model : 4BTA3.9-G11
Stand By kVA: 88
Stand By kW : 70,4
Prime kVA: 80
Prime kW : 64
Rated Current : 115
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMiNS
Engine Model 4BTA3.9-G11
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 17.3: 1
Bore 102
Strok 120
Displacement L 3,9
Air Intake Turbocharged & Aftercooled
Speed (RPM) 1500
Oil Capacity L 3,9
Standby Power kw / Hp 80 / 107
Prime Power kw / Hp 70 / 93
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 8,3
Fuel Consumption (lt / h) L Full Load 17,6
L %75 LOAD 13,2
L %50 LOAD 9,1
Frequency Hz
Power kVA 88
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 1270
Weight (Open) Kg 1076
Width (Silent) Mm 1000
Length (Silent) Mm 2800
Height (Silent) Mm 1500
Fuel Tank Capacity L 210
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
TECHNICAL SPECIFICATIONS
ENGINE
- RICARDO heavy duty diesel engine
- 12V / 24V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
-Water jacket heater
- 1500 rpm engine speed
ALTERNATOR
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
SOUND PROOF CANOPY AND CHASSIS
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection
against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â??
ground)
OPTIONAL
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
EAC 420
Engine: CUMMINS
Engine Model : NTAA855-G7
Stand By kVA: 420
Stand By kW : 336
Prime kVA: 382
Prime kW : 306
Rated Current : 550
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMINS
Engine Model NTAA855-G7
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 14.0:1
Bore 140
Strok 152
Displacement L 14
Air Intake Turbocharged,Air-Air Cooled
Speed (RPM) 1500
Oil Capacity L 39
Standby Power kw / Hp 377 / 505
Prime Power kw / Hp 343 / 460
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 55
Fuel Consumption (lt / h) L Full Load 89,2
L %75 LOAD 67,8
L %50 LOAD 47,5
Frequency Hz
Power kVA 385
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 3765
Weight (Open) Kg 3275
Width (Silent) Mm 1600
Length (Silent) Mm 4500
Height (Silent) Mm 2400
Fuel Tank Capacity L 650
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
FC 325
Engine: CUMMINS
Engine Model : NTA855-G1A
Stand By kVA: 325
Stand By kW : 260
Prime kVA: 295
Prime kW : 237
Rated Current : 425
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMINS
Engine Model NTA855-G1A
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 14.5:1
Bore 140
Strok 152
Displacement L 14
Air Intake Turbocharged After Cooled
Speed (RPM) 1500
Oil Capacity L 36
Standby Power kw / Hp 291 / 390
Prime Power kw / Hp 264 /355
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 35
Fuel Consumption (lt / h) L Full Load 61,3
L %75 LOAD 46,1
L %50 LOAD 31,4
ALTERNATOR
Frequency Hz
Power kVA 325
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22 - IP23
Power Factor 0,8
Weight (Silent) Kg 3385
Weight (Open) Kg 2955
Width (Silent) Mm 1300
Length (Silent) Mm 3900
Height (Silent) Mm 1980
Fuel Tank Capacity L 450
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 350
Engine: CUMMINS
Engine Model : MTAA11-G3
Stand By kVA: 350
Stand By kW : 280
Prime kVA: 318
Prime kW : 255
Rated Current : 458
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
AlternatIr
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMINS
Engine Model MTAA11-G3
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 15.0:1
Bore 125
Strok 147
Displacement L 10,8
Air Intake Turbocharged After Cooled
Speed (RPM) 1500
Oil Capacity L 37
Standby Power kw / Hp 310 /415
Prime Power kw / Hp 282 /378
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 50
Fuel Consumption (lt / h) L Full Load 61,2
L %75 LOAD 44,9
L %50 LOAD 27,6
Frequency Hz
Power kVA 350
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22 - IP23
Power Factor 0,8
Weight (Silent) Kg 3190
Weight (Open) Kg 2760
Width (Silent) Mm 1300
Length (Silent) Mm 3900
Height (Silent) Mm 1980
Fuel Tank Capacity L 450
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 385
Engine: CUMMINS
Engine Model : NTA855-G2A
Stand By kVA: 385
Stand By kW : 308
Prime kVA: 350
Prime kW : 280
Rated Current : 505
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model NTA855-G2A
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 14.0:1
Bore 140
Strok 152
Displacement L 14
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity L 39
Standby Power kw / Hp 343 / 460
Prime Power kw / Hp 312 / 418
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 55
Fuel Consumption (lt / h) L Full Load 71,9
L %75 LOAD 54,9
L %50 LOAD 38,9
Frequency Hz
Power kVA 385
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 3585
Weight (Open) Kg 3095
Width (Silent) Mm 1600
Length (Silent) Mm 4500
Height (Silent) Mm 2400
Fuel Tank Capacity L 650
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 825
Engine: CUMM�°NS
Engine Model : KTA38-G2
Stand By kVA: 825
Stand By kW : 660
Prime kVA: 750
Prime kW : 600
Rated Current : 1080
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model KTA38-G2
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 731 / 980
Prime Power Hp 664 / 890
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 167
Lt %75 LOAD 128
Lt %50 LOAD 90
Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9250
Weight (Open) Kg 8100
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 22
Engine: PERKINS
Engine Model : 404A-22G1
Stand By kVA: 22
Stand By kW : 17,6
Prime kVA: 20
Prime kW : 16
Rated Current : 28,8
Engine
- PERK�°NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine PERKINS
Engine Model 404A-22G1
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 23.3:1
Bore 84
Strok 100
Displacement Lt 2,21
Air Intake Naturally Aspirated
Speed (RPM) 1500
Oil Capacity Lt 10,6
Standby Power kw / Hp 20,6 / 27,8
Prime Power Hp 18,7 / 25,2
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 14
Fuel Consumption (lt / h) Lt Full Load 5,3
Lt %75 LOAD 4
Lt %50 LOAD 2,9
Frequency Hz
Power kVA 22
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 720
Weight (Open) Kg 590
Width (Silent) Mm 950
Length (Silent) Mm 2000
Height (Silent) Mm 1200
Fuel Tank Capacity Lt 125
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EA Genset supplies new, used and diesel, and portable generators Sizes from 1 kVA to 3000 kVA Variety of Fuel Types
1-3000 Kva
Manuel / Auto
with or without cabin
Engine: Cummins, Perkins, Ricardo, Baudouin, Volvo, Doosan, Sdec, John Deere, Yangdong, Deutz, Lister Petter, SD Copy Sdec
Alternator: Leroy Somer, Mecc Alte, Stamfors, EA Genser
EA Genset supplies Volvo engine diesel generators sizes from 110 kVA to 700 kVA Variety of Fuel Types
EA Genset supplies Doosan engine diesel generators sizes from 130 kVA to 825 kVA Variety of Fuel Types
EA Genset supplies John Deere engine diesel generators sizes from 33 kVA to 275 kVA Variety of Fuel Types
EA Genset supplies Deutz engine diesel generators sizes from 72 kVA to 700 kVA Variety of Fuel Types
EAR 60
Engine: RCARDO
Engine Model : D4105-ZD
Stand By kVA: 60
Stand By kW : 48
Prime kVA: 54,5
Prime kW : 43,6
Rated Current : 78,5
Engine
- RCARDO heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternatr
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
ENGINE
Engine R�°CARDO
Engine Model D4105-ZD
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 17:01
Bore 105
Strok 115
Displacement L 3,61
Air Intake TURBO
Speed (RPM) 1500
Oil Capacity L 13
Standby Power kw / Hp 60,5 / 81
Prime Power kw / Hp 56 /75
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 18
Fuel Consumption (lt / h) L Full Load 14,5
L %75 LOAD 11
L %50 LOAD 7,6
Frequency Hz
Power kVA 66
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP21 - IP23
Power Factor 0,8
Weight (Silent) Kg 1100
Weight (Open) Kg 900
Width (Silent) Mm 1000
Length (Silent) Mm 2400
Height (Silent) Mm 1500
Fuel Tank Capacity L 180
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAR 150
Engine: RICARDO
Engine Model : R6105-AZLD
Stand By kVA: 150
Stand By kW : 120
Prime kVA: 136
Prime kW : 108
Rated Current : 195,84
Engine
- RICARDO heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternatr
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine RICARDO
Engine Model R6105-AZLD
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 16:01
Bore 105
Strok 130
Displacement L 6,75
Air Intake TURBO INTER - COOLED
Speed (RPM) 1500
Oil Capacity L 13
Standby Power kw / Hp 121 / 162,1
Prime Power kw / Hp 110 / 147,45
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 23
Fuel Consumption (lt / h) L Full Load 31
L %75 LOAD 23,3
L %50 LOAD 15,5
Frequency Hz
Power kVA 150
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP21 - IP23
Power Factor 0,8
Weight (Silent) Kg 1595
Weight (Open) Kg 1350
Width (Silent) Mm 1000
Length (Silent) Mm 3150
Height (Silent) Mm 1700
Fuel Tank Capacity L 250
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 44
Engine: CUMMNS
Engine Model : 4BT3.9-G1
Stand By kVA: 44
Stand By kW : 35,2
Prime kVA: 40
Prime kW : 32
Rated Current : 57,6
Engine
- CUMMNS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMNS
Engine Model 4BT3.9-G1
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 17.3: 1
Bore 102
Strok 120
Displacement L 3,9
Air Intake Turbocharged
Speed (RPM) 1500
Oil Capacity L 3,9
Standby Power kw / Hp 40 /54
Prime Power Hp 36 /48
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 8,3
Fuel Consumption (lt / h) L Full Load 10
L %75 LOAD 7,9
L %50 LOAD 5,9
Frequency Hz
Power kVA 44
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
DIMENSIONS
Weight (Silent) Kg 1050
Weight (Open) Kg 865
Width (Silent) Mm 1000
Length (Silent) Mm 2400
Height (Silent) Mm 1500
Fuel Tank Capacity L 180
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 175
Engine: CUMMINS
Engine Model : 6BTAA5.9-G12
Stand By kVA: 175
Stand By kW : 140
Prime kVA: 159
Prime kW : 127,2
Rated Current : 229
Engine
- CUMM�°NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model 6BTAA5.9-G12
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 17.3:1
Bore 102
Strok 120
Displacement L 5,9
Air Intake Turbocharged & Charge Air Cooled
Speed (RPM) 1500
Oil Capacity L 16,4
Standby Power kw / Hp 155 / 207
Prime Power kw / Hp 140 / 187
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 10
Fuel Consumption (lt / h) L Full Load 34
L %75 LOAD 26
L %50 LOAD 17
Frequency Hz
Power kVA 175
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
DIMENSIONS
Weight (Silent) Kg 1595
Weight (Open) Kg 1356
Width (Silent) Mm 1000
Length (Silent) Mm 3150
Height (Silent) Mm 1700
Fuel Tank Capacity L 250
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 890
Engine: CUMMINS
Engine Model : KTA38-G2B
Stand By kVA: 890
Stand By kW : 712
Prime kVA: 809
Prime kW : 647
Rated Current : 1165
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternator
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model KTA38-G2B
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 789 / 1057
Prime Power Hp 711 / 953
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 176,9
Lt %75 LOAD 133,3
Lt %50 LOAD 91,3
Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9300
Weight (Open) Kg 8150
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 1000
Engine: CUMMINS
Engine Model : KTA38-G2A
Stand By kVA: 1000
Stand By kW : 800
Prime kVA: 909
Prime kW : 727
Rated Current : 1308
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model KTA38-G2A
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 38
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 895 / 1199
Prime Power Hp 813 / 1089
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 202,3
Lt %75 LOAD 153,7
Lt %50 LOAD 103,1
Frequency Hz
Power kVA 825
Voltage V 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9350
Weight (Open) Kg 8200
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 66
Engine: PERKINS
Engine Model : 1103A-33TG2
Stand By kVA: 66
Stand By kW : 52,8
Prime kVA: 60
Prime kW : 48
Rated Current : 86,4
Engine
- PERKINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine PERK�°NS
Engine Model 1103A-33TG2
Number of Cylinders 3 Inline
Injection System Direct
Compression Ratio 17.25 : 1
Bore 105
Strok 127
Displacement Lt 3,3
Air Intake Turbocharged - Air to Air Cooled
Speed (RPM) 1500
Oil Capacity Lt 8
Standby Power kw / Hp 60,5 / 82
Prime Power Hp 55 / 74
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 10,2
Fuel Consumption (lt / h) Lt Full Load 14
Lt %75 LOAD 10,4
Lt %50 LOAD 7,2
Frequency Hz
Power kVA 66
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 1200
Weight (Open) Kg 1030
Width (Silent) Mm 1000
Length (Silent) Mm 2400
Height (Silent) Mm 1500
Fuel Tank Capacity Lt 180
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
ENGINE
- RICARDO heavy duty diesel engine
- 12V / 24V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
-Water jacket heater
- 1500 rpm engine speed
ALTERNATOR
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
SOUND PROOF CANOPY AND CHASSIS
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection
against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â??
ground)
OPTIONAL
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
EA Genset supplies Ricardo engine diesel generators sizes from 20 kVA to 400 kVA Variety of Fuel Types
EA Genset supplies Baudouin engine diesel generators sizes from 20 kVA to 2750 kVA Variety of Fuel Types
EA Genset supplies Yangdong engine diesel generators sizes from 15 kVA to 110 kVA Variety of Fuel Types
EAR 82
Engine: RICARDO
Engine Model : D4105-IZLD
Stand By kVA: 82
Stand By kW : 65,6
Prime kVA: 74
Prime kW : 59
Rated Current :
Engine
- RICARDO heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternatr
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine RICARDO
Engine Model D4105-IZLD
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 16:1
Bore 105
Strok 115
Displacement L 3,93
Air Intake Turbo Intercooler
Speed (RPM) 1500
Oil Capacity L 15
Standby Power kw/Hp 72.6 / 95.5
Prime Power kw/Hp 66 / 88.4
Fuel Type Euro Dizel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 20
Fuel Consumption (lt / h) L Full Load 17.5
L %75 LOAD 15.2
L %50 LOAD 9
Frequency Hz 50
Power kVA 82
Voltage V 230 / 400 V V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP21 - IP23
Power Factor 0,8
Weight (Silent) Kg 1180
Weight (Open) Kg 990
Width (Silent) Mm 1000
Length (Silent) Mm 2400
Height (Silent) Mm 1500
Fuel Tank Capacity L 170
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAR 110
Engine: RICARDO
Engine Model : R6105-ZD
Stand By kVA: 110
Stand By kW : 88
Prime kVA: 100
Prime kW : 80
Rated Current : 144
Engine
- RICARDO heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternator
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine RICARDO
Engine Model R6105-ZD
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 16:01
Bore 105
Strok 130
Displacement L 6,49
Air Intake TURBO
Speed (RPM) 1500
Oil Capacity 16
Standby Power kw / Hp 115,5 / 154,8
Prime Power kw / Hp 105 / 140,7
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 23
Fuel Consumption (lt / h) L Full Load 22,2
L %75 LOAD 16,7
L %50 LOAD 11,1
Frequency Hz
Power kVA 110
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP21 - IP23
Power Factor 0,8
Weight (Silent) Kg 1480
Weight (Open) Kg 1230
Width (Silent) Mm 1000
Length (Silent) Mm 3150
Height (Silent) Mm 1700
Fuel Tank Capacity L 250
EAR 175
Engine: RICARDO
Engine Model : R6105-IZLD
Stand By kVA: 175
Stand By kW : 140
Prime kVA: 160
Prime kW : 128
Rated Current : 230,4
Engine
- RICARDO heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternatr
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine RICARDO
Engine Model R6105-IZLD
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 16:01
Bore 105
Strok 135
Displacement L 7,01
Air Intake TURBO INTER - COOLED
Speed (RPM) 1500
Oil Capacity L 15
Standby Power kw / Hp 145,2 /194,6
Prime Power kw / Hp 132 / 176,9
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 25
Fuel Consumption (lt / h) L Full Load 33,5
L %75 LOAD 25,2
L %50 LOAD 17
Frequency Hz
Power kVA 175
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP21 - IP23
Power Factor 0,8
Weight (Silent) Kg 1660
Weight (Open) Kg 1410
Width (Silent) Mm 1000
Length (Silent) Mm 3150
Height (Silent) Mm 1700
Fuel Tank Capacity L 250
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAR 200
Engine: RICARDO
Engine Model : R6110-IZLD
Stand By kVA: 200
Stand By kW : 160
Prime kVA: 181
Prime kW : 145
Rated Current : 260
Engine
- RICARDO heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternator
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine RICARDO
Engine Model R6110-IZLD
Number of Cylinders 6- Sral
Injection System Direkt
Compression Ratio 16:01
Bore 110
Strok 135
Displacement Lt 7,01
Air Intake TurboÃ??arj Intercooled
Speed (RPM) 1500
Oil Capacity Lt 18
Standby Power kw / Hp 173 / 231,8
Prime Power Hp 157 / 210,4
Fuel Type Euro Dizel
Governor System Mechanical
Cooling System Water Cooled
Coolant Capacity Lt 25
Fuel Consumption (lt / h) Lt Full Load 39,5
Lt %75 LOAD 29,6
Lt %50 LOAD 19,8
Frequency Hz 50
Power kVA 200
Voltage v 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP21 - IP23
Power Factor 0,8
Weight (Silent) Kg 1730
Weight (Open) Kg 1480
Width (Silent) Mm 1000
Length (Silent) Mm 3150
Height (Silent) Mm 1700
Fuel Tank Capacity Lt 220
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 30
Engine: CUMM NS
Engine Model : 4B3.9-G1
Stand By kVA: 30
Stand By kW : 24
Prime kVA: 27,2
Prime kW : 21,8
Rated Current : 39,2
Engine
- CUMM NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM NS
Engine Model 4B3.9-G1
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 17.3: 1
Bore 102
Strok 120
Displacement L 3,9
Air Intake Natural Aspiration
Speed (RPM) 1500
Oil Capacity L 3,9
Standby Power kw / Hp 27 / 36
Prime Power Hp 24 / 32
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 8,3
Fuel Consumption (lt / h) L Full Load 7,1
L %75 LOAD 5,7
L %50 LOAD 4,3
Frequency Hz
Power kVA 30
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
DIMENSIONS
Weight (Silent) Kg 880
Weight (Open) Kg 725
Width (Silent) Mm 900
Length (Silent) Mm 2200
Height (Silent) Mm 1350
Fuel Tank Capacity L 135
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
FC 63
Engine: CUMM�°NS
Engine Model : 4BTA3.9-G2
Stand By kVA: 63
Stand By kW : 50,4
Prime kVA: 57,2
Prime kW : 45,8
Rated Current : 82,3
Engine
- CUMM�°NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model 4BTA3.9-G2
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 17.3: 1
Bore 102
Strok 120
Displacement L 3,9
Air Intake Turbocharged & Aftercooled
Speed (RPM) 1500
Oil Capacity L 3,9
Standby Power kw / Hp 64 / 86
Prime Power Hp 58 /78
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 8,3
Fuel Consumption (lt / h) L Full Load 15
L %75 LOAD 11
L %50 LOAD 8
Frequency Hz
Power kVA 63
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 1160
Weight (Open) Kg 970
Width (Silent) Mm 1000
Length (Silent) Mm 2600
Height (Silent) Mm 1500
Fuel Tank Capacity L 180
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAR 94
Engine: RICARDO
Engine Model : R4105-IZLD
Stand By kVA: 94
Stand By kW : 75,2
Prime kVA: 85,4
Prime kW : 68,36
Rated Current : 122,9
Engine
- R�°CARDO heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine R�°CARDO
Engine Model R4105-IZLD
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 16:01
Bore 105
Strok 125
Displacement L 4,33
Air Intake TURBO INTER - COOL.
Speed (RPM) 1500
Oil Capacity L 15
Standby Power kw / Hp 82 / 109,9
Prime Power kw / Hp 75 / 100,5
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 23
Fuel Consumption (lt / h) L Full Load 19,1
L %75 LOAD 15
L %50 LOAD 13
Frequency Hz
Power kVA 94
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP21 - IP23
Power Factor 0,8
Weight (Silent) Kg 1250
Weight (Open) Kg 1050
Width (Silent) Mm 1000
Length (Silent) Mm 2800
Height (Silent) Mm 1500
Fuel Tank Capacity L 210
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 150
Engine: CUMMINS
Engine Model : 6BTAA5.9-G2
Stand By kVA: 150
Stand By kW : 120
Prime kVA: 136
Prime kW : 109
Rated Current : 196
Engine
- CUMM�°NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model 6BTAA5.9-G2
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 17.3:1
Bore 102
Strok 120
Displacement L 5,9
Air Intake Turbocharged & Charge Air Cooled
Speed (RPM) 1500
Oil Capacity L 16,4
Standby Power kw / Hp 130 / 174
Prime Power kw / Hp 120 / 161
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 10
Fuel Consumption (lt / h) L Full Load 30
L %75 LOAD 23
L %50 LOAD 16
Frequency Hz
Power kVA 150
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
DIMENSIONS
Weight (Silent) Kg 1550
Weight (Open) Kg 1311
Width (Silent) Mm 1000
Length (Silent) Mm 3150
Height (Silent) Mm 1700
Fuel Tank Capacity L 250
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 110
Engine: CUMMINS
Engine Model : 6BT5.9-G2
Stand By kVA: 110
Stand By kW : 88
Prime kVA: 100
Prime kW : 80
Rated Current : 144
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMINS
Engine Model 6BT5.9-G2
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 17.3:1
Bore 102
Strok 120
Displacement L 5,9
Air Intake Turbochanger
Speed (RPM) 1500
Oil Capacity L 16,4
Standby Power kw / Hp 92 / 123
Prime Power kw / Hp 86 / 115
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity L 7,9
Fuel Consumption (lt / h) L Full Load 22,3
L %75 LOAD 16,9
L %50 LOAD 11,3
Frequency Hz
Power kVA 110
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
DIMENSIONS
Weight (Silent) Kg 1375
Weight (Open) Kg 1181
Width (Silent) Mm 1000
Length (Silent) Mm 2800
Height (Silent) Mm 1500
Fuel Tank Capacity L 210
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn't permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 200
Engine: CUMMINS
Engine Model : 6CTA8.3-G2
Stand By kVA: 200
Stand By kW : 160
Prime kVA: 182
Prime kW : 145,4
Rated Current : 262
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternatir
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model 6CTA8.3-G2
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 17.3:1
Bore 114
Strok 135
Displacement L 8,3
Air Intake Turbocharged & Aftercooled
Speed (RPM) 1500
Oil Capacity L 27,6
Standby Power kw / Hp 180 / 241
Prime Power kw / Hp 163 / 218
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 12,3
Fuel Consumption (lt / h) L Full Load 44
L %75 LOAD 33
L %50 LOAD 23
Frequency Hz
Power kVA 200
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 1810
Weight (Open) Kg 1470
Width (Silent) Mm 1200
Length (Silent) Mm 3500
Height (Silent) Mm 1850
Fuel Tank Capacity L 360
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 220
Engine: CUMMINS
Engine Model : 6CTAA8.3-G2
Stand By kVA: 220
Stand By kW : 176
Prime kVA: 200
Prime kW : 160
Rated Current : 288
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMINS
Engine Model 6CTAA8.3-G2
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 18.0:1
Bore 114
Strok 135
Displacement L 8,3
Air Intake Turbocharged Air Aftercooled
Speed (RPM) 1500
Oil Capacity L 23,8
Standby Power kw / Hp 203 / 272
Prime Power kw / Hp 183 / 245
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 12,3
Fuel Consumption (lt / h) L Full Load 45
L %75 LOAD 34
L %50 LOAD 23
Frequency Hz
Power kVA 220
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22 - IP23
Power Factor 0,8
Weight (Silent) Kg 2190
Weight (Open) Kg 1850
Width (Silent) Mm 1200
Length (Silent) Mm 3500
Height (Silent) Mm 1850
Fuel Tank Capacity L 360
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 275
Engine: CUMM NS
Engine Model : MTA11-G2
Stand By kVA: 275
Stand By kW : 220
Prime kVA: 250
Prime kW : 200
Rated Current : 360
Engine
- CUMM NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM NS
Engine Model MTA11-G2
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 16.1:1
Bore 125
Strok 147
Displacement L 11
Air Intake Turbocharged After Cooled
Speed (RPM) 1500
Oil Capacity L 34
Standby Power kw / Hp 246 / 333
Prime Power kw / Hp 224 / 302
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 35
Fuel Consumption (lt / h) L Full Load 50
L %75 LOAD 38
L %50 LOAD 27,2
Frequency Hz
Power kVA 275
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation 1%
Insulation Class H
Protection Standard IP22 - IP23
Power Factor 0,8
Weight (Silent) Kg 2780
Weight (Open) Kg 2440
Width (Silent) Mm 1200
Length (Silent) Mm 3500
Height (Silent) Mm 1850
Fuel Tank Capacity L 360
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 440
Engine: CUMMINS
Engine Model : NTAA855-G7A
Stand By kVA: 440
Stand By kW : 352
Prime kVA: 400
Prime kW : 320
Rated Current : 576
Engine
- CUMM�°NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model NTAA855-G7A
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 14.0:1
Bore 140
Strok 152
Displacement L 14
Air Intake Turbocharged,Air-Air Cooled
Speed (RPM) 1500
Oil Capacity L 38,6
Standby Power kw / Hp 407 / 545
Prime Power kw / Hp 370/ 500
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 60
Fuel Consumption (lt / h) L Full Load 89,2
L %75 LOAD 67,8
L %50 LOAD 47,5
Frequency Hz
Power kVA 385
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 3765
Weight (Open) Kg 3290
Width (Silent) Mm 1600
Length (Silent) Mm 4500
Height (Silent) Mm 2400
Fuel Tank Capacity L 650
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 495
Engine: CUMMINS
Engine Model : QSZ13-G3
Stand By kVA: 495
Stand By kW : 396
Prime kVA: 450
Prime kW : 360
Rated Current : 648
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternator
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMMINS
Engine Model QSZ13-G3
Number of Cylinders 6 Inline
Injection System Direct
Compression Ratio 17:01
Bore 130
Strok 163
Displacement L 13
Air Intake Turbocharged,Air-Air Cooled
Speed (RPM) 1500
Oil Capacity L 40
Standby Power kw / Hp 470 /629
Prime Power kw / Hp 450 /603
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity L 60
Fuel Consumption (lt / h) L Full Load 101
L %75 LOAD 74,2
L %50 LOAD 49
Frequency Hz
Power kVA 385
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation ±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 4100
Weight (Open) Kg 3625
Width (Silent) Mm 1600
Length (Silent) Mm 4500
Height (Silent) Mm 2400
Fuel Tank Capacity L 650
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 790
Engine: CUMMINS
Engine Model : KTA38-G1
Stand By kVA: 790
Stand By kW : 632
Prime kVA: 718
Prime kW : 574
Rated Current : 1033
Engine
- CUMM�°NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine CUMM�°NS
Engine Model KTA38-G1
Number of Cylinders 12 - V TYPE
Injection System Direct
Compression Ratio 14.5:1
Bore 159
Strok 159
Displacement Lt 19
Air Intake Turbocharged, Aftercooled
Speed (RPM) 1500
Oil Capacity Lt 135
Standby Power kw / Hp 701 / 953
Prime Power Hp 634 / 862
Fuel Type Euro Diesel
Governor System Electronic
Cooling System Water Cooling
Coolant Capacity Lt 350
Fuel Consumption (lt / h) Lt Full Load 158
Lt %75 LOAD 122
Lt %50 LOAD 86
Frequency Hz
Power kVA 550
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 9200
Weight (Open) Kg 8050
Width (Silent) Mm 2200
Length (Silent) Mm 6200
Height (Silent) Mm 2800
Fuel Tank Capacity Lt 1750
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 70
Engine: PERKINS
Engine Model : 1104A-44TG1
Stand By kVA: 70
Stand By kW : 56
Prime kVA: 64
Prime kW : 51
Rated Current : 92
Engine
- PERKINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine PERK�°NS
Engine Model 1104A-44TG1
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 17.25 : 1
Bore 105
Strok 127
Displacement Lt 4,4
Air Intake Turbocharged - Air to Air Cooled
Speed (RPM) 1500
Oil Capacity Lt 8
Standby Power kw / Hp 65,6 / 88,5
Prime Power Hp 59,6 / 80,5
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 13
Fuel Consumption (lt / h) Lt Full Load 14,6
Lt %75 LOAD 11
Lt %50 LOAD 8
Frequency Hz
Power kVA 79
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 1280
Weight (Open) Kg 1100
Width (Silent) Mm 1000
Length (Silent) Mm 2400
Height (Silent) Mm 1500
Fuel Tank Capacity Lt 180
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 88
Engine: PERKINS
Engine Model : 1104A-44TG2
Stand By kVA: 88
Stand By kW : 70,4
Prime kVA: 80
Prime kW : 64
Rated Current : 115,2
Engine
- PERK�°NS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Alternat�¶r
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis â?? ground)
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
Engine PERK�°NS
Engine Model 1104A-44TG2
Number of Cylinders 4 Inline
Injection System Direct
Compression Ratio 17.25 : 1
Bore 105
Strok 127
Displacement Lt 4,4
Air Intake Turbocharged - Air to Air Cooled
Speed (RPM) 1500
Oil Capacity Lt 8
Standby Power kw / Hp 88 / 120
Prime Power Hp 80 / 110
Fuel Type Euro Diesel
Governor System Mechanical
Cooling System Water Cooling
Coolant Capacity Lt 13
Fuel Consumption (lt / h) Lt Full Load 18,5
Lt %75 LOAD 14,2
Lt %50 LOAD 9,8
Frequency Hz
Power kVA 93
Voltage V 230 / 400 V
Number of Phases 3
Automatic Voltage Regulator (A.V.R.) AS440
Voltage Regulation �±1%
Insulation Class H
Protection Standard IP22-IP23
Power Factor 0,8
Weight (Silent) Kg 1350
Weight (Open) Kg 1160
Width (Silent) Mm 1000
Length (Silent) Mm 2800
Height (Silent) Mm 1500
Fuel Tank Capacity Lt 210
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.