Product Description
LSRF-3 Lamp start, Run-up time and Light Flickering Analyzer - Flicker Tester is equipped with Class A fast photometric probe, so the sampling speed is up to 100kHz. It fully meets the requirement of BASIC, Energy Star V2.1, IEC TR 61547-1:2020 IEC-Pst, CA CEC, ASSIST, CIE TN006-2016 CIE SVM, IEEE Std 1789 standards, etc. It is professional for flicker test of LED lights and lamps, energy-saving lamps, etc. According to EU directives 1194/2012, 2009/125 / EC, SASO2902, COMMISSION DELEGATED REGULATION (EU) 2019/2015, COMMISSION REGULATION (EU) 2019/2020 and IEC60969 "Self-ballasted Lamps for General Lighting Services-Performance Requirements" and other requirements. The LSRF-3 can connects with PC via USB cable. The English version software can be run in Win7, Win8 and Win10, Win11 (The driver was Certificated by Microsoft)
Lamp Flicker test interface needs to work with LISUN Integrating Sphere, DC Power Source and Standard Light Source, it also can be added in LISUN LPCE-2 /LPCE-3 Integrating Sphere System or LSG-6000/LSG-1890B/LSG-1800A Goniophotometer or LSG-6000CCD/LSG-1890BCCD/LSG-1800ACCD Goniospectroradiometer.
Automatic lightning surge generator (Lightning surge immunity tester) SG61000-5 is used to assess the power cord and connect the internal switch stood in line to connect the internal switch to provide a common basis for switching the natural world and lightning caused by the high-energy transient interference performance. Performance fully meets the IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards.
Specifications:
Product Model SG61000-5SA SG61000-5SB SG61000-5 SG61000-5H-SP SG61000-5T
Output Voltage (Open) 1.2/50�¼s�20% 1.2/50�¼s�20% 1.2/50�¼s�20% 1.2/50�¼s�20% 1.2/50�¼s�20%
Output Current (Short) 8/20�¼s�20% 8/20�¼s�20% 8/20�¼s�20% 8/20�¼s�20% 8/20�¼s�20%
Output Impedance 2�© and 12�© 2�© and 12�© 2�© and 12�© 2�© 12�© and 500�© 2�© and 12�©
Output Voltage Range 0~4.8KV�10% 0~4.8KV�10% 0~6KV�10% 0~10KV�10% 0~6KV�10%
Output Current Range 0~2.4KA�10% 0~2.4KA�10% 0~3KA�10% 0~5KA�10% 0~3KA�10%
Surge Repetition 1~9999 times 1~9999 times 1~9999 times 1~9999 times 1~9999 times
Interval Time 20~9999s 20~9999s 20~9999s 30~9999s 20~9999s
Polarity Positive, Negative or Positive/Negative automatic
Phase Shift Asynchronous, Synchronization 0�~ 360� or Specific Angle
Special Function N/A Built-in surge voltage and current probe (1000:1), connect with LISUN OSP1102 directly
Operation Way Button Input Touch screen with super big LCD and built-in Windows CE
Dimensions (WxDxH) 44x45x35cm 44x45x35cm 44x45x35cm 56x69x155cm 44x45x55cm
Gross Weight About 30kg About 30kg About 30kg About 270kg About 48kg
Coupling/Decoupling
Network (CDN) Includes a 16A single phase CDN Includes a 20A 3phases CDN
Isolution Transformer
for EUT (Option) LISUN ITEU-SP4K (220V Single phase) or ITUS-SP2K (110V)
Remark: 12KV, 15KV, 20KV and more higer voltage Surge Generator can be designed according to customer request.
6KV Short Circuit Current Output Waveform (780:1) 6KV Open Circuit Voltage Output Waveform (1000:1)
Salt Spray Test Chamber | Salt Fog Test | ASTM B117 Salt Spray ChamberSalt Spray Test Chamber is applicable to the salt spray corrosive test for the protection layer of components, parts, electronic and electrical parts and metal materials and industrial products. The salt fog test chamber meets the following standards: IEC60068-2-11 (GB/T2423.17), GB/T10125, GB/T1771, ISO9227, ASTM-B117, GB/T2423-18, QBT3826, QBT3827, IEC 60068-2-52, ASTM-B368, MIL-STD-202, EIA-364-26, GJB150, DIN50021-75, ISO3768, 3769, 3770; CNS 3627, 3885, 4159, 7669 etc.
Specifications:
A waterproof structure is adopted between the chamber cover and chamber body, thus there is no salt spray overflow.
Adopts the tower spraying system and equipped with the salt solution filter system and non-crystal nozzle so as to realize even salt spray distribution and freely adjustable settlement.
The Salt Spray Chamber Working room temperature range:RT+5C~50C (The setting value cannot be lower than the current ambient temperature); Saturated barrel temperature: +40C~+63C;
The ZRS-3H Glow-wire Test Apparatus is according to IEC60695-2-1, IEC60695-2-10, IEC60695-2-11, IEC60695-2-12, IEC60695-2-13 (GB/T5169.10, GBT5169.11, GBT5169.12, GB/T5169.13) < Basic testing methods of Glow wire, basic testing methods of Glow wire device>, UL 746A, IEC829, DIN695 and VDE0471.What is glow wire test?
The Glow wire tester ZRS-3H/ZRS-3HS is suitable for resistance to abnormal heat and fire test on lighting lamps, electronic products and household appliances. It uses high-temperature coating spraying on steel structure and imported instrument display, with easy operation and stable performance. The glow wire testing equipment is applicable to flame resistance test of all levels of QC departments and corresponding enterprises.Specifications:
â?¢ Heating temperature: adjustable continuously within the range of 25~1100�°C, the accuracy of temperature is 1�°C, the resolution of temperature is �±3�°C
â?¢ Glow-wire time: 0.1-999.9sï¼?�±0.1s(time range is adjustable)
â?¢ Ignition time: 0.1-999.9s, auto record, manual pause
â?¢ Flame-out time: 0.1-999.9s (auto record and manual pause)
â?¢ Glow wire pressure on test specimen: 1�±0.2N. Limiting pressure depth is 7mm
â?¢ Glow wire: �?4 nickel (80ï¼?) and chromium (20ï¼?) Made in specific dimensions.
â?¢ Thermocouple: �?0.5 armored nickel & chromium/nickel-chromium wire, K Type.
â?¢ Automatic departure: While reaching specified glowing time, test specimen will depart from glow wire automatically.To save the delivery cost for the oversea market, LISUN designed a compact version glow-wire tester weighing less than 50kg. (Customer need to prepare additional ventilation system for ZRS-3HS)
What is glow wire capable?
The glow wire tester uses simulation technology to evaluate the fire hazard caused by thermal stress caused by heat sources such as hot components or overload resistors in a short period of time. It is one of the series of electrical and electronic components fire hazard test instruments. It is suitable for evaluating the flammability test and light-off temperature test of electrical equipment and its components and parts, as well as solid electrical insulating materials or other solid flammable materials.
Product Description
JL-X waterproof test machine is according to IEC60529:1989 +A1:1999 +A2:2013 Degrees of protection provided by enclosures(IP Code), IEC60598, IEC60335 and IEC 60034-5, GB/T-2423.2, GB4208, GB7000.1. The JL-X includes the following test grades: IPX1, IPX2, IPX3, IPX4, IPX5, IPX6, IPX7 and IPX8 (Refer to page 51 of IEC60529). It is widely used in the authentication test organization for the products such as electrical & electronic products, LED luminaires as well as in the relevant quality control department for the waterproof detection of the enclosures protection grades.
The whole JL-X waterproof test system includes:
â?¢ Drip Box (JL-12): The drip box is for IPX1 and IPX2 drip test. The drip box size is 800x800x45mm (LxWxH). The diameter of drip hole is 0.4mm. The distance between drip holes is 20mm. The sample can be over 150kg.
â?¢ Swing Pipe Water Spray Test Equipment (JL-34): It is for IPX3 and IPX4 waterproof test. The semi-diameter of swing pipe is 1meter (Any other size is also available). The inside diameter of the swing pipe is 15mm. The sample rotating table diameter is 1000mm (Or other size according to the diameter of the swing pipe), and the height is adjustable. The rotation speed is 1~5rpm which controlled by PLC panel.
Waterproof Jet Test Device (JL-56): With water supply device size is 1000x1000x600mm, the nozzle diameter is �?6.3mm (IPX5 waterproof test ) and �?12.5mm (IPX6 waterproof test). The water speed is 12.5 �±0.626L/min for IPX55 and 100 �±5L/min for IPX6
â?¢ Immersion tank Waterproof test Device (JL-7): It is for IPX7 waterproof test. The water tank size is 1000x1000x1200mm (Other size can be designed according to your request). It can test samples up to 120kg.
â?¢ Immersion tank Waterproof test Device (JL-8): It is for IPX8 test. It can simulate a water depth of 0~50m. The water immersion tank diameter is 600mm and the height is 1200mm. The compressive stress is 10 atmospheres or design according to customer's request.
Specifications:
Temperature range: RT+10~50 C
Standard wire warp of metal net: 50um; Standard spacing between wires: 75um
â?¢ Test dust: dry talc powder; Talc powder dosage: 2~4kg/m; Dust reduction method: free dust reduction
â?¢ Total test time: 0~999H (adjustable); vibration time: 0~999H (adjustable); timing accuracy: �±1 second
Vacuum: 0~10Kpa (adjustable); Pumping speed: 0~4800L/H (adjustable)
Power supply of test samples: single-phase 220V/50Hz or 100V/60Hz
Safety protection function: leakage protection, short circuit protection
The shell is made of domestic high-quality steel plate, and the surface is sprayed with paint, which is beautiful and durable.
The inner box, sample rack, etc. are made of stainless steel plates to ensure that they will not rust for a long time.
There is a transparent observation window (toughened glass material) on the door, and an LED lighting lamp is installed in the box to facilitate the observation of the internal test situation.
â?¢ There is a device for replacing dust at the bottom of the device, which can easily 100% replace the used dust.
A special device is installed to ensure that the dust does not stick to the wall and condense. The working time of the device is adjustable, and it can work automatically and alternately.
There is a suction pipe in the box, which can complete the vacuum action on the sample (require the sample to reserve the suction hole position).
Dust chamber testing control system: 7-inch touch screen + Panasonic PLC. The dust blower, dust vibration and total test time can be controlled separately. This controller has the following various arbitrary setting control functions:
1. Dust blowing time (stop, blowing): can arbitrarily choose any of continuous and periodic dust blowing time to setting;
2. Vibration time: vibration and stop vibration time are automatically alternated;
3. Preset test time: the maximum test time is 99 hours and 59 minutes;
Heating system: The circulating air duct is equipped with a heater to heat the dust to avoid dust condensation. The heat of the muffler mica sheet heating ring is safe and stable.
Vacuum system: equipped with vacuum pump, vacuum pressure, air filtration, flow meter, pressure regulating triplet, connecting pipe.
LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for photometric and colorimetric measurement of luminaries such as LEDs, LED luminaires, Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps) and CCFL. The measured data meets the requirements of CIE, EN and LM-79 clause 9.1 for the measurement of photometry and colorimetry.
System Configuration:
CCD Spectroradiometer (LMS-7000), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2008R), DC Power Source (DC-S Series), AC Power Source (LSP-500VAS), Integrating Sphere (IS-1.5MA-CASE and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W)
Measures:
â?¢ Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, Spectrum Test
â?¢ Photometric: Luminous Flux, Luminous Efficiency, Radiant Power
â?¢ Electrical: Voltage, Current, Power, Power Factor
Specification:
â?¢ Spectral Range Wavelength: 380nm~800nm (200~1050nm can be option)
â?¢ Spectral Wavelength Accuracy: ±0.5nm Wavelength Reproducibility: ±0.5nm
â?¢ Sample Scanning Steps: ±0.1nm
â?¢ Accuracy of Chromaticity Coordinate (Î?x, Î?y): ±0.003
â?¢ Correlated Color Temperature CCT: 1,500K~25,000K. CCT Accuracy: ±0.5%
â?¢ Color Rendering Index Range: 0~100.0, Accuracy: ± (0.3%rd±0.3)
â?¢ Photometric linear: ±0.5%
â?¢ Stray light:
LPCE-2 is an Integrating Sphere Spectroradiometer LED Testing System for single LEDs and LED lighting products light measurement. LEDs quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE127-1997, IES LM-79-08 and IES LM-80-08, it recommends to using an array spectroradiometer with integrating sphere to test SSL products. The LPCE-2 system is applied with a CCD Spectroradiometer (LMS-9000B or LMS-9000A) and worked with A molding integrating sphere with testing holder base function which will be more circle and the test results will be more accurate than the traditional integrating sphere.
System Configuration:
High Precision CCD Spectroradiometer(LMS-9000B or LMS-9000A), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2012 or LS2010), DC Power Source (DC Series), AC Power Source (LSP-500VAR or LSP-1KVAR), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), Optical Path Converter (LS512B), 19 Inch Cabinet (CASE-19IN)
Measures:
â?¢ Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, CQS, TM-30, Spectrum Test
â?¢ Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, EEI, Energy Efficiency Class, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux, PAR and PPF
â?¢ Electrical: Voltage, Current, Power, Power Factor (Option: VF, IF, VR, IR)
â?¢ LED optical maintenance test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time.
Specification:
â?¢ Spectral Range Wavelength: 380nm~800nm
â?¢ Spectral Wavelength Accuracy: ±0.5nm(LMS-9000A), ±0.3nm(LMS-9000B), Wavelength Reproducibility: ±0.5nm(LMS-9000A), ±0.1nm(LMS-9000B)
â?¢ Sample Scanning Steps: ±0.1nmâ?¢ Accuracy of Chromaticity Coordinate (Î?x, Î?y): ±0.003 (LMS-9000A) and ±0.002 (LMS-9000B)
â?¢ Correlated Color Temperature CCT: 1,500K~25,000K(LMS-9000A), 1500K~100,000K(LMS-9000B), CCT Accuracy: ±0.5%(LMS-9000A), ±0.3%(LMS-9000B)
â?¢ Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
â?¢ Photometric linear: ±0.5%
â?¢ Stray light:
LSG-6000 Moving Detector Goniophotometer Mirror Type C (updated version for LSG-5000/LSG-3000) is for LED measurement and completely meets LM-79-19 Clause 9.3.1 requirement. For candela intensity distribution, EEI, color temperature distribution and IES, LDT files measurement.
LSG-1800BCCD Goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800BCCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
Measurement:
Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, CCT, CRI, Color Temperature Distribution, Spectrum, (x, y)/(u, v) and etc.
Specification:
LSG-1800BCCD Goniospectroradiometer=LSG-1800B Goniophotometer System + LPCE-2 Integrating sphere Spectroradiometer System
The Europe classical goniophotometer which is fully meet EN13032-1 clause 6.1.1.3 goniophotometer type 1.
� The goniophotometer can do the B-β test with two pillars and C-γ test with single pillar & multi-function jigs
â?¢ The accuracy of angle: 0.1° (LSG-1800XCCD/LSG-1800BCCD) and 0.2° (LSG-1700BCCD)
â?¢ Work with High Accuracy and quick CCD Spectraidomeeter to measure spatial color parameters.
â?¢ Accuracy of chromaticity coordinate: ±0.0005 (under standard A lamp)
â?¢ Spectral Range Wavelength: 380nm ~780nm; Accuracy of wavelength: ±0.5nm
â?¢ Accuracy of photo detector: CIE Class A (Class L is for option)
â?¢ Connect to PC via USB, English version software can be run in Win7, Win8 or Win10
â?¢ The test result can be exported as CIE, IES, LDT and other format files. This kind of format files can be transferred by other illumination and luminaire design software such as DiaLux
Max Size for the Testing Lamp (mm) The Max Size for the Testing Lamp Max Weight
Non-Flood Lamp Diameter*Depth Flood Lamp (L*M)
LSG-1800XCCD Φ 2500*550mm 700*600mm 60Kg
LSG-1800BCCD Φ 1600*550mm 700*600mm 50Kg
LSG-1700BCCD Φ 1600*580mm 700*600mm 30Kg
Product Description
ESD simulator guns (Electrostatic Discharge Generator/Electrostatic Gun/ESD Guns) is in full compliance with IEC 61000-4-2, EN61000-4-2, ISO10605, GB/T17626.2, GB/T17215.301 and GB/T17215.322.
What is a ESD test?
The static electricity generated by the human body to the object or between two objects may cause the electrical and electronic equipment circuits to malfunction or even be damaged. The ESD generator is designed for the withstanding ESD performance measurement for the assessment of electrical and electronic equipment. ESD61000-2/ESD61000-2A has a LCD touch screen in both English and Chinese.
What is an esd simulator gun used for?
Electrostatic discharge simulator is highest electrostatic voltage can be up to 30 kv, which is enough to cover the most severe standard grade of electrostatic voltage requirement (the voltage requirements of the grade 4 air discharge electrostatic is 15 KV). The ESD test gun can be used for the most of electrical and electronic equipment for electrostatic discharge test, and also can ensure comparability and reproducibility of test.
Specifications:
Product Model ESD61000-2 ESD61000-2A
Output Voltage 0.1~20kV ±5% 0.1~30kV ±5%
Polarity Positive/Negative Positive/Negative
Energy Storage Capacitance 150pF ±10% (Replaceable)
Product Description
The LS9955/LS9956 Automatic Safety Test System (electrical safety analyzer) combined the following function in one set: Withstand Voltage Test (AC/DC), Insulation Resistance Test (IR), Leakage Current Test (LLC), Grounding Resistance Test (GR) and Power Test.
The LS9955/LS9956 Automatic Safety Test System is according to GB4706.1, IEC/EN60335-1, UL60335, GB7000, IEC60598, GB4943, IEC60950 and GB9706.1. It is used for luminaries, home application and motor tools safety test in production line or R&D Lab.
Specification:
Remote control device and can control by software (Optional)
Display all setting parameters and testing results in the same big LCD menu
PASS/FAIL limit values can be set. It has alarm sound and indicator light
Test mode programmable; 50 groups setting available, 8 test steps per group
Quick discharge. Support 50Hz and 60Hz frequency; Electric safety wall detecting feature
�¢?�¢ The LS9955 can do test for Withstand Voltage (AC/DC), Insulation Resistance (IR), Leakage Current (LLC) and Ground Resistance (GR)
The LS9956 can test for Withstand Voltage (AC/DC), Insulation Resistance (IR), Leakage Current (LLC), Ground Resistance (GR) and Power
EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. The EMI-9KB EMI receiver is made of full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meets CISPR15:2018, CISPR16-1, GB17743, FCC, EN55015 and EN55022.System Configurations:
EMI-9KC Test System includes: EMI-9KC EMI Receiver built-in Attenuator (9K-1GHz), LISN Artificial Network Power, CDNE-M316 Coupling/Decoupling Network for Emission, Isolation Transformers, Attenuator and cables.
EMI-9KB Test System includes: EMI-9KB EMI Receiver (9K-300MHz), LISN Artificial Network Power, CDNE-M316 Coupling/Decoupling Network for Emission, Isolation Transformers, Attenuator and cables.
EMI-9KA Test System includes: EMI-9KA EMI Receiver (9K-30MHz), LISN Artificial Network Power, Isolation Transformers, Attenuator and cables.Option instruments to work with the EMI-9KC, EMI-9KB and EMI-9KA EMI receivers:
LISUN LSP-500VARC/LSP-1KVARC Pure Sine Wave AC Power Source for EUT
LISUN SDR-2000B Magnetic Shielding Cabinet for the EMI Receiver System
LISUN VVLA-30M Three Loop Antenna to test 9k-30MHz radiation
LISUN AB-CLP Absorbing Clamp to test the home applications & motor tools
LISUN VOL-CP RF Current Probe to the conducted disturbance voltageSpecification:
Detection frequency range: 9kHz~1GHz (EMI-9KC), 9kHz~300MHz (EMI-9KB), 9kHz~30MHz (EMI-9KA)
Frequency stability: 1 10^-6
Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) 1kHz
Test Tolerance: ±2 dB
Measure and Detection method: PK, QP and AV
Measure range: 20dB V~140dB V
Frequency scanning step frequency: 20Hz~2MHz
Sweep bandwidth: 200Hz; 9kHz; 120kHz
Connect PC via USB cable and software can run on Win7, Win8, Win10, Win11
Product Description
The Portable CCD LED Colorimeter Spectroradiometer has the following versions which can measure different parameters:
LISUN Model Function Wave Range
LMS-6000 illuminance (lux), E(Fc), Ee(W/m2), Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram 380-780nm
LMS-6000B LMS-6000 Parameters+Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE S009/E:2002 350-800nm
LMS-6000BF LMS-6000 Parameters+Flicker test, Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE S009/E:2002 350-800nm
LMS-6000F LMS-6000 Parameters+Flicker test 380-780nm
LMS-6000L cd/m2, fL, Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram 380-780nm
LMS-6000P LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb_Ratio 380-800nm
LMS-6000S LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb_Ratio, Rf and Rg according to TM-30 350-950nm
LMS-6000UV UV-A, UV-B, UV-C and UV total Radiant Irradiance, UV hazard irradiance, UV spectrum, Dominant Wavelength, Peak signal, Start wavelength, End wavelength. Please click here to see the LMS-6000UV Test Report. 200-400nm
LMS-6000SF LMS-6000 parameters+Flicker+Plant Lighting parameters+TM-30 350-950nm
LMS-6000I Input and Output Control via RS485 380-780nm
LMS-6000C LMS-6000 parameter without PC software 380-780nm
Standards:
Fully meet CIE 177, CIE-13.3 , Optical-Engineering-49-3-033602, and IEEE.
The Chroma Meter Specifications:
Spectral resolution: ±0.2nm, Reproducibility: ±0.5nm
Accuracy of chromaticity coordinate ( x, y): ±0.005
Illuminance range: 5~200,000lx
LCD screen: 5inch high definition IPS capacitive touch screen and resolution is up to 480*854
With 4000mAh rechargeable Li-ion battery which can continuously work for 20 hours
Dimensions: 135mm*80mm*23mm
Connect to PC via USB cable. English version software can run on Win7, Win8 or Win10
According to IEC60695-2-2, IEC60695-11-5 and GB/T-5169.5, ZY-3/ZY-3S needle flame test equipment is applied in the production and quality control department of lighting products, hyperpiesia electrical apparatus, domestic appliance, machine electric appliance, electrical machine, power tool, electronic instrument, electrician instrument and technical equipment. Also, the apparatus is suitable for the industry of insulation material, engineering plastics and solid combustible material.Specifications:
Angle of burner: 45�° (when in test) / 0�° (when adjust the flame height)
Needle flame burning time: 0~999.9s ±0.1s (adjustable, 30s in general)
After-flame time: 0~999.9s ±0.1s, auto record and pause manually
Height of flame: 12mm±1mm (gauge is included)
Gas: 95% butane
Test range of temperature: 0~1000
The temperature rises from 100 ±2 to 700 ±3 within 23.5 seconds ±1s
Thermocouple: 0.5mm K type
Applied with touch screen and remote controlTo save the delivery cost for the oversea market, LISUN designed a compact version needle flame test equipment weighing less than 50kg. (Customer need to prepare additional ventilation system for ZY-3S)
What is a needle flame test?
The full name of IEC 60695-2-2 is Fire hazard testing Part 2: Test methods Section 2 Needle-flame test. It was prepared by IEC technical committee 89: Fire hazard testing. The following is the related introduction of IEC 60695-2-2 Scope.This section of IEC 60695-2-2 specifies a needle-flame test to simulate effect of small flames which may result from fault conditions within equipment, in order to assess by a simulation technique the fire hazard.It is applicable to electrotechnical equipment, its sub-assemblies and components and to solid electrical insulating material or other combustible materials.What is flame retardant test methods?
In the case of horizontal needle flame test HB classification, the sample size is required to be 125mm in length, 13mm in width, and no more than 13mm in thickness. The sample is placed horizontally, the sample clamp is clamped to one end of the sample, and the ignition device is at a 45 degree angle to keep the flame position unchanged. Apply 30±1S to the other end of the sample holder, and place a metal mesh and a freely movable fixed frame horizontally under the sample holder,