To determine whether toys & other articles intended for use by children under 3 years old present choking, aspiration, or ingestion hazards because of small parts. If any objects can fit completely into the cylinder without compressing & in any orientation, it is defined as a "Small Part". Its internal dimensions simulate the fully expanded throat of a child under 3 years old.
Standards: 16 CFR 1500.48, ASTM F963 4.8, EN-71 1998 8.2, ISO 8124.
Standard export packate.
The Kinetic Energy Tester is used to test related materials from the launch of the toys and toys from the launch of a non-exclusive material that may be caused by the ejection of some, but not all of the potential risk of accidents.
Complies to standards£ºASTM: F963-03
EN-71-03
Main Technical Parameter
Power Supply: AC 220V/ Single phase, 50 HZ
Max time: 15.000000S
Display range: 0.000001--15.000000S
Speed display range: 0.007M/S¡ª10000.000M/S.
Input channels: Internal /external channels (external channel is optional)
The distance between front sensor and rear sensor: 100mm, tolerance 0.1mm
Keys: internal / external channels, reset keys.
Standard export package.
To determine whether accessible sharp points on toys are likely to cause injury. If the accessible sharp point penetrates a specified depth into the small rectangular opening of the tester, the LED is illuminated to indicate that the point is unacceptably sharp. Toys intended for use by children under 8 years old are subject to this requirement before or after use & abuse testing.
Dimensions: 112, 16, 16mm ;Weight: 80 g
Standards: 16 CFR 1500.48, ASTM F963 4.8, EN-71 1998 8.14, ISO 8124
Accessories: weight, batteries, bulb 2 pieces
Related Standards ASTM F963 EN71.
Standard export package.
To determine whether any part or component of a toy can be contacted by the probe. The probe simulates the finger of the infant or child touching the accessible points or edges of a toy, which may then be subject to tests of sharp points or sharp edges. Accessibility probes are designed for two age groups: Probe A for 0-36 months
Probe B for 37-96 months.
Standard: 16 CFR 1500.48; 16 CFR 1500.49; EN-71; GB 6675-2003.
Standard export package.