To determine whether any part or component of a toy can be contacted by the probe. The probe simulates the finger of the infant or child touching the accessible points or edges of a toy, which may then be subject to tests of sharp points or sharp edges. Accessibility probes are designed for two age groups: Probe A for 0-36 months
Probe B for 37-96 months.
Standard: 16 CFR 1500.48; 16 CFR 1500.49; EN-71; GB 6675-2003.
Standard export package.
Supplier: Safety test equipment, glow wire tester, needle flame tester, tracking index tester, horizontal and vertical burning tester, black test corner, salt spray tester, test probe, ball pressure apparatus, spring impact tester, inclined plane tester, dielectric strength tester, accessibility probes, rigid test probe, test pin, test finger probe, test finger nail, test probe with force, environmental test chamber, k type thermocouple, dust test chamber
Iec60335 temperature black test corner To measure the temperatures in the base or in the fixing surfaces for applicances and luminaires in operation according to iec60335-1/2006-09 clause 11.2 and 11.3. Can be used to the temperature test of all kinds of electronic products supply, in conformity with the standards requirement of the environmental conditions. Advantages Test corner boards are "stand alone basic" and could be easily combined into a test corner by using some track. Packed with strong wooden case
Precision salt spray corrosion test chamber Technical Specifications: Model AUT0-60 Auto-90 Auto-120 Inner Box Size W*D*H(mm) 600*450*400 900*600*500 1200*800*500 Outside Box Size W*D*H (mm) 1070*580*1030 1380*800*1150 1700*950*1210 Power 220V,1.5KW ,50HZ 220V,1.5KW ,50HZ 220V,3KW,50HZ Testing capacity 108L 270L 480L Brine Tank Volume 10L 15L 20L Reference standards CNS:3627,3385,4159,7669,8886; JIS:D0201,H8502, H8610,K5400,Z2371; ISO: 3768,3769,3770; ASTM: 8117,B268 Technical Features: Box material : Local temperature and humidity inside and outside the box are used for A-level gray high-corrosive PVC, for salt spray, copper acetate, and other test specifications Test. Saturation pressure barrel : It uses the A-level German imports of gray PVC material. Laboratory Racks: It uses sophisticated Class A gray PVC material designed "V" shape long, products tested by the 15 ¡ã -30 ¡ã angle be adjusted. Laboratory cover:It uses a 5mm thick transparent imported high toughness PVC board, bending method designed to cover 100 degree ridge-type transparent. With power failure memory function of time, so after the original call time to complete the remaining time of the experimental work, with a double over-temperature protection, water shortage warning, ensure safety. Technical basis:According to JIS, ASTM, CNS, GB standard parameter setting operation. Standard Laboratory Air pressure barrel Salt spray test NSS ,ACSS 35¡ãC¡¨¤1¡ãC 47¡ãC¡¨¤1¡ãC Corrosion test CASS 50¡ãC¡¨¤1¡ãC 63¡ãC¡¨¤1¡ãC Systems: •Heating system It uses steam heating, heating speed, reduce the standby time, when the temperature reached, the thermostat automatically switches the state, the temperature accuracy, less power consumption •Control system High-precision temperature controller, Japan OML timer to control the time, the overall temperature error of ¡¨¤ 1¡ãc. Packed with strong wooden case
The fiskeâ® 210 micro-sample osmometer The fiskeâ® 210 freezing-point osmometer requires only a 20âµl sample size, which provides accurate osmolality results in less than 90 seconds. For convenience, the fully accessible probe design is easy to clean and service. The 210 is not only your most reliable option, it's the easiest to use. Just pipette 20âµl of sample into a disposable sample tube, then place the tube into the test chamber. Lower the probe into the sample and push the "test" button. Results are displayed in ninety seconds. Features Alphanumeric display: results, user prompts, and instrument diagnostics are clearly displayed. Easy push-button operation: requires minimal operator training. Printer, rs232c and barcode scanner ports: a full range of data handling options is available. Unit connects easily to printer, computer and scanner. Automatic calibration: no fine-tuning or user adjustments during calibration. The instrument's microprocessor automatically makes calibration adjustments at the push of a button. Smallest sample size: only 20âµl of sample needed. Solid-state cooling: the 210 has no liquid cooling bath; no maintenance required.
Resistor Iec 61032 : 1998 Figure 12 -- test probe 18 ( small finger probe ª¦8.6 ) -- finger : metal material -- handle : insulating material The extension of the handle represents the arm of the child. The handle is provided with an extension 451.6 mm long , and the probe should be applied with or without this extension, whichever is the more onerous condition. Both joints shall permit movement in the same plane and the same direction through angle of 90íp. This probe is intended to simulate access to hazardous parts by children of more than 36 months or less than 14 years. The low size1000(pec)
High-precision; small size; simple, easy accessibility and the operation panel that makes machines easy to understand, easy to operate. Automatic temperature compensation, with the help of the temperature probe, can automatically correct the impact of temperature on the pH. Accurate thermometer, the temperature of an independent probe, the sensor can be quickly tested solution temperature. BNC with the composite electrode and 9 V battery, around the world to facilitate the replacement of batteries and electrodes. Economical and practical, fully in line with a wide range of industries need to test.
1. Fully automated, discrete, random access . 10. Perfect function of quality control management is convenient for users to manage the clinical test result. 11. Detecting in the whole reaction process with reaction curve, convenient for users to monitor thoroughly and scientifically analyze the detection data. 12. Supporting software can implement the function of detecting surplus reagent through liquid level induction of reagent probe. 1150*980*1350
Discrete automatic, random access with two independent discs and independent stirring needle 200-400 photometric tests per hour, more than 40 items on board Reusable reaction cuvettes with advanced 8 steps cleaning Automatic probe cleaning High sensitive liquid level detection Back spectrophotometry with 9 wave lengths, accurate testing result Light weight construction, flexible installation and maintaining. 100kg - 210kg
Demo condition fujikura arc fusion splicer with fluke fiber inspector mini- minimal use Fsm-60s splicer with ct-30 cleaver fluke ft500 tester Features: Rugged construction providing shock, dust and moisture resistance Dual monitor position with automatic image orientation Automatic arc calibration and fiber identification User-selectable fiber clamping method – sheath clamp or fiber holders Auto-start tube heater feature Color lcd display with anti-reflective coating for excellent visibility in bright sunlight Simultaneous battery charge and splicer operation Long life battery (up to 160 splice/heat cycles per charge) Detachable work table incorporated into the transit case Fsm-60s fusion splicer kit includes (with cleaver): Ct30a cleaver Adc-13 ac adapter Acc-14 ac cord Spare electrodes (pair) Sheath clamp Usb cable Splicer carrying strap Quick reference guide Video instruction manual Jp-05 splice sleeve cooling tray Transit case with carrying strap Ft500 fluke networks fiberinspector mini - information The ft500 fluke networks fiberinspector mini video microscope puts the solution to contaminated end-faces in the palm of your hand. This portable video microscope works ten times faster than traditional scopes. Simply insert the probe and inspect installed fiber connectors through the bulkhead adapters without accessing the backside of the patch panels. Ft500 includes: Fiberinspector mini video microscope includes fiber probe and display, ac adapter/battery charger, probe adapter tips (st, sc and universal 2.5mm patch cord tip) and soft carrying case). * we are selling this as a complete kit and will not separate.