Supplier: Starter, generator, armature, solenoid switch, field coil
Jt no. Qdj1206d-000 Oem 028000-9040 128000-1560 128000-1561 281005-6160 281005-6161 281008-9107 Wai 2-2265-nd Engine Toyota 13b/14b
Jt no. Qdj1206f-000 Oem 028000-5880 028000-5881 028000-5882 R39341 Wai 2-1726-nd Lester 16658 Engine 188d 207d Car no. Cummins 3604648 Lucas Lrs01256 Lrs1256 Jt no. Qdj1206f-000 Oem 028000-5880 028000-5881 028000-5882 R39341 Wai 2-1726-nd Lester 16658 Engine 188d 207d Car no. Cummins 3604648 Lucas Lrs01256 Lrs1256
The ATO 3-pole AC contactor has the advantages of compact size and easy connection. High Performance and long electrical life. Greater environmental immunity. Sealed structure which improves its safety features. As contactors are used for high-current load applications they are designed to control and reduce the arc produced when the heavy motor currents are interrupted. Other than the low current contacts, they are also setup with Normally Open contacts. These are devices which handle more than 20 Amperes current and over 100 Kilo Watts power. When current is passed through the contactor, the electromagnet starts to build up, producing a magnetic field. Thus the core of ac contactor starts to wind up. This process helps in energizing the moving contact. Thus the moving and fixed contacts make a short circuit. Thus the current is passed through them to the next circuit. The armature coil brings in high current in the initial position. This reduces as soon as the metal core enters the coil. When the current is stopped, the coil gets de-energized and thus the contacts get open circuited. See more information on: https://www.ato.com/40-amps-contactor.
Electromagnetic contactor (contactor) refers to an electrical appliance that uses the current flowing through the coil to generate a magnetic field in industrial electricity to close the contact so as to control the load. The contactor is composed of electromagnetic system (armature, stator core, electromagnetic coil), contact system (normally open contact and normally closed contact) and arc extinguishing device. Structural composition Electromagnetic contactor is mainly composed of transmission device (electromagnetic mechanism), contact device (actuator) and arc extinguishing device. 1. Electromagnetic mechanism The electromagnetic mechanism includes three parts: moving core (armature), static core and electromagnetic coil. The electromagnetic coil is connected with current to generate electromagnetic suction and drive the contact to act. Electromagnetic mechanism is one of the important parts of electromagnetic contactor. The electromagnetic mechanism is composed of coil, iron core (static iron core), armature (moving iron core), pole shoe, iron yoke and air gap. The coil and iron core in the electromagnetic mechanism do not move in the working state; The armature is movable. The electromagnetic mechanism converts the electromagnetic energy generated by the electromagnetic coil into mechanical energy through the action state and action process of the armature and the corresponding mechanical mechanism to drive the contact to close or open, so as to realize the control purpose of the controlled circuit.
product description JWXC-7 type infinite relay is a relay widely used in railway signal technology, called signal relay, and it is an important part of railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JWXC-7 type infinite relay is used as a general purpose and air-proof step-down relay in the signal circuit. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. product structure Infinite relay is the typical structure of AX series relay, which is composed of electromagnetic system and contact system. The electromagnetic system includes coils, iron cores, vehicle irons and armatures. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the yoke by a butterfly-shaped steel wire, which is flexible in movement. There is a heavy hammer in the transmission part of the Yantie to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, vehicle iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence.
Product Usage The JWXC-2.3 type infinite relay is used as a DC track relay in the signal circuit. Features 1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized. 2. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual, and installs the stop piece at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay. 4. The contact system is composed of ordinary contacts, and there are four groups of ordinary contacts for switching on and off. 5.The rated current of the relay is 280mA DC. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70KPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. product structure Infinite relay is the typical structure of Ax series relay, which is composed of electromagnetic system and contact system. The electromagnetic system includes coil, iron core, choke and armature. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the iron by a butterfly-shaped steel wire, which is flexible in movement. There is a heavy hammer in the transmission part of the armature to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, choke iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence. Installation method
Product Usage The JZXC-H18 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit. Installation Precautions 1. When installing the relay, make sure that the insulation interval between the sockets is intact, the socket hanging spring is intact, and the socket identification pin is in the correct position and should not be missing. 2. Pay attention to the relative position between the relay and the socket when plugging in the relay to avoid damage to the relay or socket during plugging. 3. When repairing and replacing the relay, first remove the fixed relay spring, and then pull out the relay. Do not use excessive force or shake left and right when pulling it out, as it may damage the relay or socket. Applicable environment a) Ambient temperature: -40~+60 b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Product electrical life The relay contact is connected to DC24V1A resistive load; its electrical life is 1Ã??106 times Structural characteristics The electromagnetic system includes coils, iron cores, irons and armatures. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil. It is mainly to install a half-wave or full-wave rectifier circuit composed of diodes above the contact group.
Product Usage The JC type AC relay is used as a buck-boost control relay, a signal switch track power supply supervisory relay, and a main screen and a backup screen conversion relay in the power supply screen. Can replace JZXC-20000 rectifier relay. Features 1. The relay is an AC 220V heavy spring force electromagnetic relay with reinforced contacts. 2. The relay magnetic system is a clap-on AC magnetic system, which is composed of an iron core, a coil and an armature. 3. It adopts silver-silver oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 4. The contact system is composed of ordinary contacts. There are four groups of moving on and off conversion ordinary contacts and two groups of moving and closing ordinary contacts. The structure of the ordinary contacts is the same as that of a non-polar relay. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Dimensions