Product Usage
The JC type AC relay is used as a buck-boost control relay, a signal switch track power supply supervisory relay, and a main screen and a backup screen conversion relay in the power supply screen. Can replace JZXC-20000 rectifier relay.
Features
1. The relay is an AC 220V heavy spring force electromagnetic relay with reinforced contacts.
2. The relay magnetic system is a clap-on AC magnetic system, which is composed of an iron core, a coil and an armature.
3. It adopts silver-silver oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance.
4. The contact system is composed of ordinary contacts. There are four groups of moving on and off conversion ordinary contacts and two groups of moving and closing ordinary contacts. The structure of the ordinary contacts is the same as that of a non-polar relay.
Applicable environment
a) Ambient temperature: -40~+60;
b) Relative humidity: not more than 90% (temperature +25C);
c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);
d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;
e) Working position: horizontal;
f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.
Dimensions
Product Introduction Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JJC1 AC enhanced contact relay is a reversible motor control relay in the power supply screen. It can replace JZJXC-7200 rectifier strengthened contact relay. Features 1. The JJC type AC enhanced contact relay is an AC 24V heavy elastic type enhanced contact electromagnetic relay. 2. The relay magnetic system is a clap-on AC magnetic system, which is composed of an iron core, a coil and an armature. 3. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 4. The relay contact system is composed of two parts: ordinary contacts and enhanced contacts. There are two groups of movable and broken ordinary contacts; four groups of movable and closed enhanced contacts. The structure of ordinary contacts is the same as that of non-polar relays. The enhanced contacts are specially designed high-power contacts. Mechanical properties Number of contact groups: 4QJ; 2H Identification pin number: 12, 54; Ordinary contact gap: not less than 1.3mm; Strengthen the contact gap: not less than 5mm; Ordinary pallet gap: not less than 0.35mm; Reinforce the gap of the support plate: not less than 0.1-0.3mm; Ordinary contact pressure: dynamic breaking contact is not less than 150mN; Strengthen the contact pressure: the moving and closing contact is not less than 600mN; Contact uniformity error: not more than 0.20mm.
Triac based ssr Used in control pannel for controlling heater It is generally used in plastic, rubber, pharma, chemical, paper industries 10pecs 48mm*48mm*30mm
product name AC filament conversion relay: JZSJC2 product usage JZSJC2 AC Filament Conversion Relay is suitable for railway signal lighting circuit. When the main filament of the 12V, 25w dual-filament signal bulb is broken, the auxiliary filament will be lit through a set of movable break contacts to realize the conversion of the main and auxiliary filaments. , And alarm through another set of contacts. Applicable environment a) Temperature: -40~+60; b) Air pressure: not less than 70kPa (equivalent to 3000m above sea level); c) Relative humidity: not more than 90% (temperature -25C); d) Vibration: frequency 5H2~2H2, displacement amplitude not greater than 1mm, frequency 22H2-50H2, acceleration amplitude not greater than 20m/s2; e) There should be no harmful gas causing explosion hazard around, and dust-proof measures should be taken. Mechanical properties Contact gap: not less than 0.8mm; Dynamic contact pressure: not less than 150mN; Dynamic breaking contact pressure: not less than 150mN; Contact uniformity error: not more than 0.1mm; The joints are formed together: not less than 0.1mm. Electrical characteristics Rated current: 2.1AAC; Working value: not more than 1.5AAC; Release value: not less than 0.5AAC; Contact resistance: no more than 0.052 Insulation resistance The temperature of the relay and socket is 15C~35â??, the relative humidity is 45%~80%, and the insulation resistance should not be less than 100M�©. Insulation withstand voltage Between the coil winding and other parts of the relay, the insulation withstand voltage between each contact and the contact and the ground should be able to withstand AC sine wave 50Hz, 1000V effective value voltage for 1Min, there should be no breakdown or flashover. Product electrical life Wei Electric implements broken wire conversion according to the lighting circuit, 15 to 20 actions per minute, and its electrical life is not less than 3*105 test method Requirements for test satellites, meters, and power supplies The accuracy of the measuring gauge should not be less than 0.02mm; The accuracy of the feeler gauge should not be lower than level 2; The measurement error of the dynamometer should not be greater than 2%; The accuracy of the AC ammeter used for testing should not be lower than level 1; The power supply voltage fluctuation range should not exceed 5%, the waveform is a sine wave, and the frequency is 50�±1Hz. Characteristic test The electrical characteristics test circuit of the relay is shown in the figure below.
product name AC filament conversion relay: JZSJC2 product usage JZSJC2 AC Filament Conversion Relay is suitable for railway signal lighting circuit. When the main filament of the 12V, 25w dual-filament signal bulb is broken, the auxiliary filament will be lit through a set of movable break contacts to realize the conversion of the main and auxiliary filaments. , And alarm through another set of contacts. Applicable environment a) Temperature: -40~+60; b) Air pressure: not less than 70kPa (equivalent to 3000m above sea level); c) Relative humidity: not more than 90% (temperature -25C); d) Vibration: frequency 5H2~2H2, displacement amplitude not greater than 1mm, frequency 22H2-50H2, acceleration amplitude not greater than 20m/s2; e) There should be no harmful gas causing explosion hazard around, and dust-proof measures should be taken. Mechanical properties Contact gap: not less than 0.8mm; Dynamic contact pressure: not less than 150mN; Dynamic breaking contact pressure: not less than 150mN; Contact uniformity error: not more than 0.1mm; The joints are formed together: not less than 0.1mm. Electrical characteristics Rated current: 2.1AAC; Working value: not more than 1.5AAC; Release value: not less than 0.5AAC; Contact resistance: no more than 0.052 Insulation resistance The temperature of the relay and socket is 15C~35, the relative humidity is 45%~80%, and the insulation resistance should not be less than 100M.
Product Introduction The JJJC7 AC enhanced contact relay is an important element in the interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and the opening and closing of the signal machine. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JJC7 AC enhanced contact relay is used in the distributed power supply screen. Features 1. The JJJC7 type relay is an AC 220V heavy spring force type reinforced contact electromagnetic relay. 2. The relay magnetic system is a clap-on AC magnetic system, which is composed of an iron core, a coil and an armature. 3. The use of silver-silver oxidation requires contacts, which has the characteristics of strong anti-adhesion and low contact resistance. 4. The relay contact system consists of two parts: ordinary contacts and enhanced contacts. There are two groups of moving on and off switching ordinary contacts; the two sets of moving on and off switching enhanced contacts, the structure of the ordinary contacts is the same as the stepless relay, and the strengthened contacts Specially designed high-power contacts. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Insulation withstand voltage Under the standard atmospheric conditions of the test, the absolute resistance of the relay should not be less than 100MQ. Under the condition that the air pressure is not lower than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz, 2000V rms voltage, there should be no breakdown flashover after 1min, the voltage when repeating the test Should be 75% of the original test voltage value.
Product Introduction The JJJC5 AC enhanced contact relay is an important element in the interlocking equipment, and the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the way, and control the opening and closing of the signal machine. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JJ small C5 AC enhanced contact relay is used as an indicator light power supply supervisory relay in the power supply screen of the small station. Mechanical properties Number of contact groups: 2QHJ; 2QH Identification pin number: 13, 43; Ordinary contact gap: not less than 1.3mm; Strengthen the contact gap: not less than 4mm; Ordinary pallet gap: not less than 0.35mm; Reinforce the gap of the support plate: not less than 0.1-0.3mm; Ordinary contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Strengthen the contact pressure: the dynamic contact point is not less than 600mN; the dynamic disconnection point is not less than 300mN; Contact uniformity error: not more than 0.20mm.
product description JWXC-7 type infinite relay is a relay widely used in railway signal technology, called signal relay, and it is an important part of railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JWXC-7 type infinite relay is used as a general purpose and air-proof step-down relay in the signal circuit. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. product structure Infinite relay is the typical structure of AX series relay, which is composed of electromagnetic system and contact system. The electromagnetic system includes coils, iron cores, vehicle irons and armatures. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the yoke by a butterfly-shaped steel wire, which is flexible in movement. There is a heavy hammer in the transmission part of the Yantie to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, vehicle iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence.
Product Introduction JZXC-0.14 type rectifier relay is an important element in interlocking equipment, and is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the way, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JZXC-0.14 type rectifier relay is used in the signal circuit for the filament supervision or conversion relay for the electric concentration of small stations and the local power supply in the automatic block section. Features 1. The relay is a heavy elastic rectifier electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized.
Product Features The JZXC-20000 rectifier relay is used as a buck-boost control relay in the power supply screen; as a signal channel and track power supervision relay; and a conversion relay between the main screen and the backup screen. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Features 1. The relay is an AC 220V heavy elastic rectifier electromagnetic relay, which adopts the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized. 2. It adopts silver-silver oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and a stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay. 4. The relay consists of two parts: a rectifier circuit and a non-polar relay. The rectifier circuit is a bridge rectifier circuit composed of four 1N4007 silicon rectifier diodes. The input of the rectifier is alternating current, and the rectified current output to the coil is direct current. 5. The relay contact system is composed of common contacts, with six groups of common contacts for switching on and off. Mechanical properties Number of contact groups: 6QH; Identification pin number: 23, 55; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics Rated value: AC220V Magnetizing value: AC220V Release value: not less than AC 35V Working value: not more than AC105V Coil resistance: 10000 (1±10%) Q2 coils in series, connect 1, 4, use 7, 8; time characteristics (At rated voltage): The pull-in time is not more than 01S, and the slow release time is not more than 0.15