ALTUS AL 81 IC Clothes Dryer Machine 8 KG
* 200 Amps Normally Open 24VDC with auxiliary switch * Double coils * Customized available
C&S MCCB , Moulded Case Circuit Breakers - Winbreak2 RANGE : Rating: 16A~1600A , Poles: 3P & 4P. Moulded Case Circuit Breakers - Winbreak RANGE: Rating: 15A ~ 1200A , Poles: 2P, 3P & 4P Moulded Case Circuit Breakers - WiNbreak1 RANGE : Rating: 16A ~ 400A in 3P & 4P Rating: 16A ~ 200A in single pole
Supplier: Electronic components like sockets, fluke product like electronic tester, hand tools, ic testers & programmers, interactive whiteboard, lab furniture, soldering & de soldering systems, test & measurement instrument, variac & dimmerstats
Digital Trainer is intended for elementary as well as advance training of Digital electronics and for bread board digital circuits, AND, OR, NOT, NAND, NOR, XOR, Three State Buffer, RS Latch, JK Flip Flop, Monostable Multibrator. and UP/ DOWN Counter. Practical experience on this board carries great educative value for R & D labs, Science and Engineering Students. Specifications: 01. Breadboard : Solderless Bread board with 1680 inter connected Tie Points 02. Pulse Switches : 2 No?s. Bounce free push buttons 03. Logic Switches : 8 logic level Switches in Dip type . 04. Power Supply : Fixed: +5V at 750 mA 5. Power Sockets : Logic Probe Power Supply Sockets 06. Logic Input : 8 LED buffered logic level indicators 07. Variable Clock : Fine adjustment of clock frequency. Clock range selection L : 10 ? 40 Hz, H : 1K ? 20K Hz. 08. Jacks : 2mm to BNC Socket 2 No. 2mm to 4mm Socket 2 No.
Decade Resistance Box are precision instruments intended for general laboratory use, R&D and educational purposes. These are used as a multiplier, shunt, substitution resistor, or as an arm for AC or DC bridges. Specifications Metal Film Resistor Accuracy 1% Power Rating 1Wat Maximum Working Voltage 500 Volts.
BRAND: L&T MCCB DU/DY With Thermal - Magnetic Release DU MCCB Range 2 Pole / 3 Pole / 4 Pole MCCBs DU250C/DU250/DU400N MCCBs DTH With Thermal - Magnetic Release Conforms to IS/IEC 60947-2 l 25kA, 36kA, 50kA & 70kA breaking capacities l Adjustable short-circuit settings: 6 - 10 x In** l Manual, Rotary and Motorised versions available@ l 20A to 630A, 3P & 4P l Adjustable overload settings: 0.8 - 1.0 x In l Ics= 100% of Icu* l Wide range of accessories
Structure Size : 160 Rated Power : 1.25 - 6 kW Pole Number : 16 - 4 Protection Class : IP23 Voltage : 380 V (Contact us for different voltages.) Frequency : 50 Hz (Contact us for different frequencies and speed control devices.) Build Type : A4 - B3 - B9 Mechanical Structure : Body cast iron Cooling Type : IC 410 (Cooling by forced cooling fan) Insulation Class : F (Contact us for different insulation classes.) Working Regime : S3 - S5 Ambient temperature : 40 C (Contact us for higher ambient temperatures.) Motor Protection : On request, a thermistor can be installed and a motor protection relay can be provided.
Structure Size : 132-315 Rated Power : 2.2-160 kW Pole Number : 4 - 6 - 8 Protection Class : IP55 Voltage : 380 V Frequency : 50 Hz Build Type : B3 - B5 - B3 / B5 Mechanical Structure : Body and covers are cast iron, legs are ductile iron Cooling Type : IC 411 Insulation Class : A - E - B - F - H Working Regime : S3- 100-60-40-25% Ambient temperature : 40 C (Contact us for higher ambient temperatures.) Motor Protection : Thermistor and motor protection relay for over 250 types (Applicable to smaller types.)