Please click here to check who's online and chat with them.

Foretech Engineering Solutions Pvt. Ltd.

Supplier From India
Aug-06-22
Supplier : Variable Frequency Drives, Plc, Dcs, Electrical Items, Field Instruments Like Flow Transmitter, Pressure Transmitter, Level Transmitter, Temperature Transmitter Sensors Etc

Established: 2020

Verification Status



Contact Details:
Plot No.1, 1St Floor, S.m.i.e Phase-Ii, Opp. Ymca, Faridabad, Haryana 121006, India
Faridabad 121006
Haryana India


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Foretech Engineering Solutions Pvt. Ltd.

VERIFIED
Jun-05-21

Differential Transmitter

$1.39K
MOQ: Not Specified
 
Differential Transmitter In All Brand Emerson , Rosemount , Honeyweel , F+h , E+h Etc
Jan-18-20
 
BROTEK India has all in one, universal, intelligent RF admittance microwave level switch, microwave field generate
alarm when measuring point inserting few millimeters in to the medium, also its not effect by foam condensate and residue,
by using microwave measuring principle possible to detect a conductive and non conductive medium from: liquid, solid
and solid powder. Output of switch only when measuring point is completely cover by medium, also its measuring point
has no dead end and is hygienic so level switch is suitable for CIP (Clean-in-Place), WIP (Wash-in-Place) and
SIP (Sterilization-in-Place), available with different process connection as per industries requirement, and different
temperature version for set up to 200 deg C
Mar-26-25

Transmitter, GP2A2B21AB4M5D1

$365 - $860 / Piece (EXW)
MOQ: Not Specified
 
China factory Transmitter GP2A2B21AB4M5D1 for Rayalaseema power
Deyang YOYIK have power plant professional accessories, non-standard pieces, to spare parts for processing. Only need to figure the number of other companies need drawings and drawings number. If you have any questions or concerns, please contact us. YOYIK has a good talent pool, the company is developing, you need to support, in order to witness its growth.

Yoyik can offer many spare parts for power plants as below:

#DF-Transmitter GP2A2B21AB4M5D1-DF
Rotary Torque Sensor CS-3 M16-L60
displacement transducer 6000TDG
Pt100 -RTD temperature probe 30cm Probe length, Fixing Thread: 1/8â?? G or NPT
steam turbine bolt heater ZJ-20-T16
displacement inductive sensor 191.36.09.15
Thermocouple Control WRN2-239
non-contact displacement sensor 2000TDZ-A
liquid level float switch BNA15/16-M569
turbine speed sensor bme tcu ZS-04 L=80
sensor rpm ZS-01 L=90
Guide Wave Level Gauge 704-511A-140/7MA-A110-130
pt100 sensor WZP2-24SA
lvdt-sensor HTD-200-3
speed meter sensor ZS-03 L=75
thermocouple cable WRNK2-332
temperature probe sensor WZPK-338
Digital display AC ammeter PA194I-ASY1
5000 rpm torque sensor CS-1-G-110-05-01
ceramic thermocouple WRNKD2-04A-II
Pressure Switch 9AG-EF45-N1-F1A
stainless steel pressure gauges HM100-250-R-M20Ã??1.13-BF
non-contact displacement sensor TDZ-1-31
Transmitter GP2A2B21AB4M5D1

sensor lvdt ZD-6000TDA
angular displacement sensor ZDET600B
angular displacement sensor HL-6-150-15
RPM Sensor magnetic SZCB-01-B01
lvdt displacement sensor TDZ-2
LVDT Position Sensors B151.36.09.04-014
rotation sensor 70085-1010-428
sensor rpm ZS-04 L=100
thermocouple cable TE-208
stainless steel Thermocouple TC03A2-KY-2B/S19
wzp pt100 WZPK-237S
steam turbine bolt heater ZJ-17-8B
thermowell WRNK2-331T
lvdt transducer displacement HTD-250-3
industry thermometer WTY 1201606
speed sensor symptoms CS-1(G-080-05-01)
lvdt-sensor 1000TDGN-30-01
output shaft speed sensor ZS-02 L=65
Gear tooth sensor QBJ-CS-1 L=100
electronic pressure switch RC0126NZ097H
rtd sensor WZP2-6520NMF
shaft rotation sensor CS-1-D-075-03-01
RPM Sensor magnetic CS-1 L=100
LVDT Displacement Sensors 6000TD-10-01-01
lvdt-sensor TDZ-1E-021
Transmitter GP2A2B21AB4M5D1

DFYL-2025-3-26-ZYR
Jul-17-09
Supplier From Dubai, United Arab Emirates
 
Long battery life. By stand-by mode, battery lasts 1000h.
Power switch remotely controllable. You can control on/off of rcs-50 by rcs-20t. Controllable range is nearly 100m.
Original code between rcs-50 (transmitter) and rcs-20t (remote controller) avoid interference with the other unit if someone use it in the same area.
<*1>bug detectors can not detect sleeping transmitter.


(RCS-50)
Size... 67 x 21 x 70 (73)mm / antenna °3 x 220mm
Weight... 162g (with alkaline batteries) / antenna 3g
Power supply... "006p" (6f22/6lr61) 9v battery x 1
Battery life... Approx. 62h (6lr61, continuous transmission) / approx. 1000h (stand-by mode, no transmission)
Available channels... Uhf-a, uhf-b
Mic effective range... 15m from circle point.
(RCS-50)
Size... 42.5 x 21 x 112 (120) mm / rod antenna 20mm (shortened) - 460mm (extended)
Weight... 162g (with alkaline batteries) / antenna 3g
Power supply... "006p" (6f22/6lr61) 9v battery x 1
Battery life... Approx. 11h (6lr61, continuous transmission)
Controlling rcs-50... Keep pressing button 5 seconds to turn on rcs-50. Same procedure to turn it off. Rcs-20t uses vhf frequency for remote control.
GOLD Member
May-18-19
Supplier From Pune, Maharashtra, India
Apr-12-19
 
HR3051-LT Differential Pressure Level Transmitter

overview
The diaphragm of the differential pressure level transmitter is used to prevent the medium in the pipeline from directly entering the pressure sensor component of the differential pressure transmitter. It uses a filling fluid such as silicone oil to transmit pressure between the transmitters.
The HR3051-LT differential pressure level transmitter be used for measuring the level, density, pressure, and flow of a liquid, gas, or vapor and converts it into a 4-20 ma DC HART current signal output. The RP2001 can also communicate with the RST375 handheld te
rminal or the RSM100 Modem for parameter setting, process monitoring, and more. The measuring range of the HR3051-LT differential pressure level transmitter (when not moved) is 0-1kPa~2MPa, and the rated pressure of the liquid level flange is: 1.6/4MPa, 6.4MPa, 10MPa, 150psi, 300psi or 600psi.
Working principle and structure
The HR3051-LT differential pressure level transmitter consists of a HR3051-DP differential pressure transmitter and a soldered liquid level flange. Its working principle is the same as HR3051-DP type differential pressure transmitter (see HR3051-DP type differential pressure transmitter technical specification), except that the pressure transmission path on the positive pressure side is slightly different: the pressure acting on the high pressure side is firstly The diaphragm and filling liquid on the liquid level flange pass through the transmitter body and finally reach the high voltage side of the measuring sensor.
Comparison of range code and range limits
Range code Minimum range Maximum range Rated pressure (maximum)
B 1kPa 6kPa Rated pressure of the liquid level flange
Oct-31-19
 
NCS-PT105 series Smart Pressure Transmitter with advanced, mature, reliable 3151 capacitance sensors has been designed meticulously by combining advanced microprocessor technology and digital capacitance measurement technology. The powerful functions and high-speed computing capability of the microprocessor make it have excellent qualifications such as smart, high precision, high reliability, stable zero and so on. Its LCD can display many physical parameters (e.g. pressure, temperature, current and so on). It can realize the functions such as zero adjustment, range settings by key-press operation, and it is easy for field testing.

NCS-PT105 series Smart Pressure Transmitter supports HART, FF, and PA protocol and can measure pressure, differential pressure, liquid level, flow, and other industrial parameters. It can be widely used in the petroleum, chemicals, electricity, and metallurgical industries, etc..

According to the type of measurable pressure:

Model Pressure type

NCS-PT105 SR Micro-differential pressure transmitter

NCS-PT105 SG Gauge pressure transmitter

NCS-PT105 SA Absolute pressure transmitter

NCS-PT105 SD Differential pressure transmitter

NCS-PT105 SH Differential pressure transmitter for high static pressure

According to the protocol:

Model Communication Protocol type

NCS-PT105 H HART

NCS-PT105 F FF H1

NCS-PT105 P PROFIBUS PA



As a transitional communication protocol in fieldbus, HART protocol achieves digital transmission on the existing analog transmission lines, and is compatible with existing analog signal control system. Either FF H1or PROFIBUS PA is a new generation of digital communication protocol, used in field connection, and linking field devices. International Standard IEC61158-2 is used in physical layer. Therefore, either FF H1or PROFIBUS PA is fieldbus actually.



As following, Smart Transmitter with HART protocol is named as HART Smart Transmitter; Smart Transmitter with FF H1 protocol is named as FF Smart Transmitter; Smart Transmitter with PROFIBUS PA protocol is named as PA Smart Transmitter, All of these (Transmitters with the three types of fieldbus protocol) are named as Smart Pressure Transmitters or Smart Transmitters. In addition, HART Smart Transmitter has passed explosion-proof certification from National Supervision and Inspection Center for Explosion Protection and Safety of Instrumentation (NEPSI).
Apr-19-20

Pressure Transmitter

$253
MOQ: Not Specified
Supplier From Barjora, West Bengal, India
 
Pressure Transmitter for Sandvik LH307/LH410
Dec-20-19
 
Notice

1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse.

2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface.

3. The wiring should be strictly in accordance with the instructions of our company.

4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument.

5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds.

6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct.

7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse.

8.The quality assurance period is 12 months.
Intelligent Operation Method



1. LCD shows the output percentage or process pressure. Press the S key to select the display percentage or pressure.Press Z key to select pressure unit KPa or Mpa when displaying pressure.

2. Press S+Z key for 8 seconds, then release it at the same time, press Z key to set the zero value; Press the S key set the range. note: this function can only be triggered once an operation.

3. Adjustments to zeros or ranges may cause changes in the displayed options, i.e.The percentage being displayed becomes pressure or KPa becomes Mpa, etc. All these changes are shown only in the display, and have no effect on the internal parameters of the transmitter, pressure detection and current output. After adjusting the zero point and range, the S and Z keys can be used to select the desired percentage or pressure.

4. Zero-setting in field pressure-free state: 30 seconds after pressing S+Z key, the display shows zero time at the same time release the two keys, that is, zero.
Simulated operation method

1.Zero-setting in pressure-free condition: The potentiometer with the word "zero" on the circuit board is adjusted to zero when it is displayed on the spot.(Note: Clockwise increase, counterclockwise decrease)

2.The potentiometer marked "range" on the circuit board can not be adjusted without standard pressure, so as to avoid the disorder of measurement range.

Verification Status