offers the most comprehensive range of porcelain line post insulator up to highest AC and DC system voltages with the most progressive technology, engineering and life time. Short production time, tighter tolerances, flexible design, extra-high mechanical strength and extended creepage distances are possible by isostatic process. Ceramic Post Insulator Application: Used for insulating and fixing wires in high voltage overhead transmission and distribution lines; Advantage: 1.Solid and puncture-proof: Being in an atmospheric space and exposed to pollution, rain, and other natural phenomena make them at risk of being damaged due to punctures. 2.Flexible creepage distance: The post insulators should have a reasonable creepage distance that will not endanger the integrity of the insulating path. This distance shields against tracking. 3.High mechanical strength: Post insulators are exposed to compressive, torsional and bending forces on a daily basis. Therefore, the insulator must have high mechanical properties to overcome these forces, otherwise it will just collapse and be more expensive to replace. Ceramic insulator has good chemical and thermal stability, almost no aging deterioration, and has good electrical and mechanical properties Applicable Standard: IEC, GB, BS, ANSI, AS or Customer's requirement; If you have any questions, please feel free to contact us We will provide you with the most professional answer in the shortest possible time.
The railway insulator is an insulator product suitable for electrified railway tunnels with complex operating conditions. It is installed between steel rail and tie plate, for adjusting rail gauge and electrically insulating railroad rails, rail clips and rail bolts from the interior of a concrete sleeper. It can effectively prevent pollution flashover accidents and reduce the workload of cleaning and maintenance. Due to its small size, especially when the tunnel clearance is small, it is irreplaceable for ceramic insulator and glass insulators. Why insulated Rails are main parts of the rail tracks. They lead the train and transfer the pressure of the wheels to the sleepers. It must have a continuous smooth surface with minimum resistance. Currently in the electrified railways or automatic block zone the two rails double as signal lines of track circuits and loop line for locomotive traction. So rails must be insulated in case of stray current interference. Usually insulators and insulated rail joints are used in rail tracks. What are the types of railway insulators The following is the classification method of railway insulators: 1. Classification by structure Insulators are divided into: column (post) insulators, suspension insulators, pin insulators, butterfly insulators, tension insulators, anti-fouling insulators and bushing insulators. In addition, the cross arm can be regarded as a generalized insulator. 2. According to different functions It is divided into ordinary insulators and anti-fouling insulators. With years of experience designing and manufacturing railway insulators, has developed a new concept to improve safety and performance while optimizing cost considerations for our customers. is willing to cooperate with colleagues from all over the world and customers in the wider power field.
As a professional ceramic insulator supplier, offer different kinds of Station Post Insulator for Substation, Line Post Insulator, disc suspension insulator, etc. Ceramic Insulators are manufactured in various sizes and also as per customers requirement. What is a ceramic insulator Ceramic insulators are ceramic materials used to insulate electrically-conductive materials or temperature-controlled enclosures. In the context of electrical insulation, ceramic insulators are usually limited to the insulation of electrically conductive materials on an industrial or municipal scale. Advantage Ceramic insulators have good chemical and thermal stability, almost no aging deterioration, and have good electrical and mechanical properties.
Voltage class kv: 15, 25 & 35 - easier construction thanks to the light weight - excellent impact resistance - excellent mechanical properties - the characteristics to repel water of polymer material
Upto 400kv As per customer requirement
1.Polymer Insulator Character: 1.1High mechanical strength; 1.2Good performance of hydrophobicity and anti-pollution; 1.3 Excellent electrical Performance; 1.4 Small volume and light weight. 2.TID polymer Insulator Character: 2.1 We adopt the advanced injection producing technology for housing and the design of the shed adopt unique aerodynamics principle. 2.2 Good Raw material : We use HTV silicone rubber which hydrophobicity can reach to HC1 level We use hot dip Galvanizing steel fitting ,the thickness of the zinc more than 100 m. We use ECR rod as the core which is high acid resistant. 7200Hr testing passed . 2.3 Special marking design. We use the double seal design between the rubber and the fitting. We can mark your logo on the fitting or rubber. 2.4 Excellent Manufacture Technology: Perfect match between fitting and rod With imported end-fitting crimping equipment ,ensures the mechanical performance of the product Perfect bound between silicone rubber and the rod. 2.5 The unique end fitting sealing structure improves product sealing reliability 2.6 The strict inspection measures ensure the perfect quality of every product. Product Advantages: 1.Light weight It is small in size and in light weight, it is about 1/5 to 1/9 of the porcelain insulator in the same grade voltage, so itâ??s convenient for transportation and installation. 2.Good Anti-pollution Composite insulator has a good anti-pollution performance, so it can operate safely in polluted area, it requires neither annual cleaning or maintaining at zero. 3.High Anti-fouling property Good aging resistance performance, strong ability of anti-pollution flashover and good electric corrosion resistance, can ensure that the internal insulation core will not be affected by moisture. 4..Strong shock resistance Composite insulators have good brittleness resistance, strong shock resistance and there no brittle fracture accident. Composite insulators are interchangeable with ceramic. 5.Stable Performance The composite insulator has high mechanical strength, reliable structure and stable performance, which provides a guarantee for the safe operation of the line.
It has good performance of hydrophobicity and anti-pollution. The main model are FZSW-10KV/4KN, FZSW-22KV/6KN, FZSW 132KV/10KN.
Composite Station Post Insulator Name: Composite Station Post Insulator No.: F-003 Addtime: 2017-06-22 Views : 25 General Introduction Sali supply Suspension Clamp, Pole Line Hardware, Eye Bolt, Pigtail Bolt, Insulator, Polymer Insulator, Orcelain insulator, Precing Connector, Preformed Guy Grip, Vibration Damper, Fastener etc. All of them with best quality and low price. This product is applied to high voltage power line service, and has features of good hydrophobicity,anti-aging, anti-leakage trace and electrical erode proof, tensile strength and bending strength, strong mechanical strength, with good performance in shock resistance good quakeproof & brittle-break proof, light weight, easy to installation, and the installation outline of top and base are the same size with porcelain pin type, they can exchange to use each other. Sali is a leading manufacturer of Insulator, Polymer Insulator, Orcelain Insulator, Glass Insulator, Guy Grip Deadend, Composite Pin Insulator, Wedge Tension Clamp, Anchor Clamp etc. Welcome to contact us to know more. Main Technical Parametes (performance meet GB/T20142-2006 IEC61952) Product Model Rated Voltage (kv) Rated Mechanical Bending Load (kn) Rated Catileve Load (kn) Structure Height H. (mm) Min. Arc Distance (mm) Min. Creepage Distance (mm) Diameter of Shed (mm) Lightning Impulse Withstand Voltage (peak)(kv) P.F.1min Wet Withstand Voltage (virtual value)(kv) FZSW-10/5 10 5 0.6 215 125 290 100/90 75 42 FZSW-15/5 15 5 0.6 245 170 600 138/118 105 45 FZSW-20/8 20 8 1.2 400 300 920 122/92 125 50 FZS-20/8 20 8 1.2 420 320 700 138 125 50 FZSW-35/6 35 6 2 460 360 900 148/118 185 95 FZSW-66/8 66 8 1.5 770 650 1930 160/130 325 140 FZSW-66/12 66 12 2 760 630 1940 215/185 325 140 FZSW-110/6 110 6 1.5 1150 1050 2950 160/130 325 200 FZSW-110/10 110 10 4 1220 1060 3260 215/185 450 200 FZSW-220/10 220 10 4 2250 2050 6520 215/185 950 395 Note: 1.The mini creepage distance is a little different as per product height. â?¢ 2. The product height and top, bottom accessories install dimension could be choosed from table, also could be supplied their dates to us by yourself. The 220kV insulator could be one section , and also two sections. 3. 110~220kV composite core post insulator only could be applied to busbar post or lateral post. It should be discussed with manufacturer if the prohucts are used for knife switch post.