Specification of 2CP5 series pressure sensor (0.5~4.5Vsignal output) Pressure range!G 0-15psig ~ 0-650psig Performance!G Precision: !O 1.2% span (linearity, hysteresis, repeatability, and calibration). Temperature deviation!G!O0.013%FXC Operating temperature!G-40FXC to 135FXC Physical properties!G Pressure resistance!G5X15-75psi!F3X100-300psi!F2X500+psi!C Burst pressure!G2CP5 1500 psi (brass)!F2CP50 2500 psi (plated steel)!C Random vibration!G (50-2000 Hz)!G11g!C Cycle life!G10M F.S cycle!C Fall (in either axis)!G1.5m!C Electrical connection!GNema 4X, IP65!C Electrical characteristics!G Power voltage!G4.5 to 5.5 VDC!C Power current (Max@5.5Vdc no load)!G8 mA max!C Output load: 10K ohms typical. Overvoltage protection!G16 VDC!C Short-circuit protection!GYes!C EMC (10MHZ-512MHz)!G50 V/m The output voltage (Vout): 0.5 to 4.5 Vdc t typical. Output current (maximum decrease or source)!G2.5 mA!C Output response time!G10 mS!C Reverse voltage!G14 VDC!C EMC (512MHz-1GHz)!G25 V/m!C ESD (CDF-AEC-Q100-002)!G15k V!C
The fuel rail sensor, commonly referred to as the Fuel Pressure Sensor, it is installed at one end of the oil rail to measure the fuel pressure in the common rail pipe. Fuel Pressure sensor 4930429 is a part of vehicle s fuel system and designed to monitor the fuel pressure that is present at the fuel rail. It sends this signal to the ECU, which then uses it to make adjustments to the vehicle s fuel and timing. When the sensor has an issue it can cause problems with the performance of the vehicle. Quality Guarantee :1 year, and strictly in accordance with the standard quality inspection The products are 100% new and carefully packed. 1.Name: Fuel Pressure sensor,Fuel high Pressure sensor 2.Certification: CE, TS16949 3.Model NO.: 4930429 4.Function: Control emissions in combustion environments 5.Application: BOSCH CUMMINS DODGE KOMATSU 6.Ciondition: 100% NEW 7.Weight(g): 50.7g 8.Deliverytime: 7-15 days 9.Packing: Neutral packing Customize according to customer needs
Pressure-based output control (for compression and decompression) Low pressure switch (4 output) High pressure switch (4 output) Stable split system (pressure sensor and controller) Rotation of freezing models or booster pump models with operating number control
Efficient step control Multi/semi-multiple control CDU control Intelligent rotation Low/high pressure alarm Sensor calibration Sensor error detection
Pressure range: -1 600bar (optional) Accuracy: 0.5%F.S. Supply voltage: 12 36(24)VDC Output: 4-20mA (2 wire) 0-10V (3 wire) Operating temperature: -40 105 Compensation temperature: -20 80 Operating Current: 3mA Temperature drift (zero & sensitivity): 0.03%FS Long-term stability: 0.2%FS/year Response Time: 3ms Overload pressure: 150%FS Burst pressure: 300%FS Cycle life: 500,000 times Pressure connection: G1/4, NPT1/4 Electrical connection: Hirschman DIN43650C, M12 Housing Material: 304 Stainless steel Water-proof level: IP65 Explosion-proof level: Exia CT6 Weight: 0.25kg Medium: non-corrosive environment Sensor core: Al2O3-96% ceramic sensor Cable length: 1.0m by default
HR5300 Pressure Controller over view HR5300 smart pressure display controller is a multi-functional product integrating pressure measurement, display and control. It uses high-quality pressure sensitive components. The millivolt signal output from the sensor is adjusted by high-integration analog front-end and sent to the microprocessor for compensation. Correction, the final result is displayed on the LED screen, and the control signal is simultaneously output according to the set conditions; the product has power monitoring and watchdog monitoring functions, long-term safe and reliable use, simple operation and convenient use. The product range is rich, widely used in hydropower, tap water, petroleum, chemical, machinery, hydraulic and other industries to measure, display and control the pressure of fluid medium. Features .High quality pressure measurement sensing elements .Digital error correction .Live display and control .Button adjustment, easy to use .Strong overload resistance and corrosion resistance .Reverse power protection, over voltage protection .Anti-surge, electromagnetic interference
Pressure Transmitter for Sandvik LH307/LH410
Notice 1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse. 2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface. 3. The wiring should be strictly in accordance with the instructions of our company. 4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument. 5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds. 6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct. 7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse. 8.The quality assurance period is 12 months. Intelligent Operation Method 1. LCD shows the output percentage or process pressure. Press the S key to select the display percentage or pressure.Press Z key to select pressure unit KPa or Mpa when displaying pressure. 2. Press S+Z key for 8 seconds, then release it at the same time, press Z key to set the zero value; Press the S key set the range. note: this function can only be triggered once an operation. 3. Adjustments to zeros or ranges may cause changes in the displayed options, i.e.The percentage being displayed becomes pressure or KPa becomes Mpa, etc. All these changes are shown only in the display, and have no effect on the internal parameters of the transmitter, pressure detection and current output. After adjusting the zero point and range, the S and Z keys can be used to select the desired percentage or pressure. 4. Zero-setting in field pressure-free state: 30 seconds after pressing S+Z key, the display shows zero time at the same time release the two keys, that is, zero. Simulated operation method 1.Zero-setting in pressure-free condition: The potentiometer with the word "zero" on the circuit board is adjusted to zero when it is displayed on the spot.(Note: Clockwise increase, counterclockwise decrease) 2.The potentiometer marked "range" on the circuit board can not be adjusted without standard pressure, so as to avoid the disorder of measurement range.
General Description The series of pressure transducers use imported high-quality pressure sensors and special integrated modules, through fine temperature, zero, full range, and non-linear compensation to achieve accurate measurement and transmission of pressure changes in liquid, gas, steam and other media. Technical Index Measuring medium: liquid, gas, steam Pressure range: -0.1MPA~0~60MPA Accuracy grade: ±0.2%FS, ±0.5%FS Stability: â?¤0.2%FS/year Temperature drift: â?¤0.02%FS/(range 0~70) Environment temperature: -20+85 Storage temperature: -20+85 Output signal: 4-20mA or 1-5VDC Supply voltage: 12-40VDC Allow overload: two times the quota voltage Explosiveproof grade: intrinsically safeia II C T6 flameproof dII C T6 Wetware material: 316 stainless steel and 1Gr18Ni9Ti Shell material: die casting alloy aluminum,surface epoxy spraying Pressure interface: M20X1.5 Weight: ordinary 0.75kg, with on-site instructions 1kg Structure Type x1 Connection x2x31 x4 The link mode and output signal of the compact tranmitter are as follows: Two-wire system: 1 Positive power supply 2 Negative power supply 3 Empty 4 Shell Three wire system: 1 positive power supply 2 Negative power supply (Negative sharing with signals) 3 Signal+ 4 Shell x5 The connection mode of aviation plug transmitter is as follows: Two-wire system(direct outlet type) 1 Red wire connection positive power supply 2 Black wire connection negative power supply Notice 1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse. 2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface. 3. The wiring should be strictly in accordance with the instructions of our company. 4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument. 5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds. 6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct. 7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse. 8.The quality assurance period is 12 months.