1. Current overload or line surge shutdown 2. High temperature compressor shutdown. 3. High pressure alarm shutdown. 4. Low pressure alarm shutdown. 5. Low oxygen cocentrator alarm. Oxygen concentrator: 0.5-5L/min Purity: 95%+_3% Working system Continuous Power Supply AC230V.50Hz/AC220V.60HZ AC120V.60Hz Power: 390VA Net Weight: 16kg( Gross weight: 18.5kgs) Warranty: Long-life compressor designed for 1000 hours of maintenance-free use. Size: 33*26*54cm
The popular portable oxygen machine car oxygen concentrator adjustable oxygen-concentrator Intelligent self-checking system with error code showing in LCD Super low noise 24 Hours Continuous Working Long lifespan of Molecular Sieves
Product: PSA oxygen generator with cylinder filling system Equipment: Air compressor / Air refrigeration unit / Air purification system / Fractionating column / Filling system Advantages: Cost-effective, Easy to install and maintain, Automatic and unattended operation, Produces oxygen from only raw material - ambient air
PSA Oxygen Generator System produce oxygen from 5m3/h to 50m3/h (33lpm-825lpm). Itsâ?? modular design could flexibly meet various needs of various applications. And the oxygen concentration could reach 93%-99.5%. To get a concentration of 99.5% oxygen, produce 93% oxygen is the first stage, then in the second stage: separate inert gases in oxygen purification system to get 99.5% oxygen. Which could meet the special oxygen demands of operating room and ICU of the hospital.
Technology brief There has been a growing demand for small and medium-sized oxygen equipment with rapid development of the national economy in recent years. Beijing Peking University Pioneer Technology Co., Ltd. (hereinafter referred to as PKU PIONEER), seizing this market opportunity with its advanced technology and engineering experience of more than 100 sets of oxygen equipment, has produced the customized the new skid-mounted PSA oxygen equipment through its continuous development and innovation. The PSA-O2 generator meets a wide range of requirements for users in need of small and medium-sized oxygen equipment. It has remarkable advantages on its stability, simplicity, efficiency and energy saving. Production Capacity 50Nm3/h-450Nm3/h, equivalent to liquid oxygen of about 1.7 TPD-15.4 TPD. Typical Applications The PSA-O2 generator is widely used in water treatment, flue gas ozone denitrification, kiln combustion, pulp bleaching, aquaculture, medical and other fields. Technical Advantages 1. Advanced single-vessel process Compared with the traditional double-vessel process, the world-leading single-vessel process requires less equipment but brings more stable performance with easier operation and maintenance. 2. High efficiency lithium-based molecular sieve The third generation of high-efficiency lithium-based oxygen generation molecular sieve (PU-8) has a lithium ion exchange rate of over 99%, bringing plenty of advantages such as high strength, high nitrogen and oxygen selectivity, large bulk density, uniform particles, long service life, etc. In combination with the proprietary automatic filling technology, the stability of the molecular sieve bed is effectively guaranteed. 3. Special valves for oxygen generation Special valves for oxygen generation are more suitable for VPSA oxygen process, offering good sealing, fast switching speed, stable performance and other characteristics, along with outstanding low failure rate and easy maintenance. 4. Modular integrated design Compared with the conventional double-vessel process, the equipment is more compact and the plot area can be reduced by more than 20%. 5. Low operation cost The power consumption of oxygen is as low as 0.29-0.32kWh/Nm3, the annual maintenance cost is 30% lower than that of a common PSA oxygen generator. The annual comprehensive operation cost is also reduced by more than 50%, compared with the cost of common PSA oxygen generator or purchasing liquid oxygen.
Feature It is a ventilation device for infant with novel structure and good performance, and chooses opening ventilation mode with high frequency and little tidle volume, so the airway pressure is low.If you want to know more. A. The tidal air can letout with constant pressure, constant current or accurately adjustable flow. B. Opening ventilation, opening intubation makes it not need casing bag, little resistance as expiration is suited for the ventilation management of infant. C. Evident effectiveness of treating ards can be shown with inserting small tube and jetting oxygen through nasal vestibule, which is secure and doesn't cause pressure wound easily. D. Peep and humidifier volume can be adjusted accurately. E. Alarm system with sound and light when no oxygen, poor of electric quantity or low airway positive pressure. F. Heated humidifier can be used for good effectiveness of humidifying. G. Accumulator jar, it can be used while being charged and can last for more than four hours. Specifications Frequency10+150 breaths/min I/e ratio1:1, 1:1.5+ 1:3 and inverse ratio Pressure atomizer rate>=6ml/h Process ventilationt=10min, Proi:f(150):f(35)=7:3 Proii:f(35):f(150)=7:3 Storage battery4ah, automatic charge when 12v Sigh:3breaths/min Alarm:alarm when battery voltage is lower than 11v, alarm lasts 6 seconds if no oxygen, alarm with audible signals and flashing light when the airway pressure is over 0.8kpa Cpap0+0.5kpa Peep0+0.20kpa Oxygen concentration adjustable:21%-90% Jetting volume rangeo+600ml/time Ventilation mode:hfjv(high frequency jet ventilation);cpap(continuous positive airway pressure);hfjv+peep(positive end-expiratory pressure), hfjv+sigh(sigh), process ventilation i and process ventilation ii. Standard packaging.
Feature A. The device adopts impulse jet oxygen feeding technique with great flow rate of oxygen feeding in a shot while, when feeding oxygen, it adopts change mode major in reflux and many kinds of gas flow mechanism such as convection, laminar flow, sheet flow and so on concurrently, which is good to increase partial pressure of oxygen rapidly, at the same time fluctuation of thorax caused by increasing oxygen flow into airway is good to let out co2. B. Jet oxygen feeding is supported by pressure when inspiration and secure certain peep effect when feeding oxygen, so as to reach good effectiveness of oxygen feeding. C. Accumulator jar, it can be used while being charged and can last for four hours after having been charged. D. Alarm system with sound and light when lack of electric quantity or airway pressure. E. 300cg chooses digital display of import pressure sensor. F. 300cg has three kinds of airway limited pressure alarm for adult, child and infant. G. The device disposes pressure humidifier which has good humidigying effectiveness. Specifications Power supply:ac220v+22v 50hz+1hz I/e ratio1:1, 1:1.5+ 1:3 and 3:1 Driving pressure 0+0.15mpa Sigh:6breaths/min, i/e=1:4 Pressure regulator limit:0.30mpa Cpapnot less than 1kpa Oxygen concentration adjustable:40%-90% Process ventilationt=10min, infinite recursion Proi:f(150):f(35)=7:3 Proii:f(35):f(150)=7:3 Alarm:alarm with light and sound for no gas or no power or airway pressure is over Inner battery:4ah 12v Ventilation mode:hfjv(high frequency jet ventilation);cpap(continuous positive airway pressure), hfjv+sigh(sigh); process ventilation i and process ventilation ii, manual control mode. Standard packing