Feature: A. The device adopts impulse jet oxygen feeding technique with great flow rate of oxygen feeding in a shot while, when feeding oxygen, it adopts change mode major in reflux and many kinds of gas flow mechanism such as convection, laminar flow, sheet flow and so on concurrently, which is good to increase partial pressure of oxygen rapidly, At the same time fluctuation of thorax caused by increasing oxygen flow into airway is good to let out CO2. B. Jet oxygen feeding is supported by pressure when inspiration and secure certain PEEP effect when feeding oxygen, So as to reach good effectiveness of oxygen feeding. C. Accumulator jar, it can be used while being charged and can last for four hours after having been charged. D. Alarm system with sound and light when lack of electric quantity or airway pressure. E. 300CG chooses digital display of import pressure sensor. F. 300CG has three kinds of airway limited pressure alarm for adult, child and infant. G. The device disposes pressure humidifier which has good humidigying effectiveness. Specifications Power supply:AC220V+22V 50HZ+1HZ I/E ratio·ª1:1,1:1.5+ 1:3 and 3:1 Driving Pressure ·ª0+0.15MPa SIGH:6breaths/min, I/E=1:4 Pressure Regulator Limit:0.30MPa CPAP·ªnot less than 1KPa Oxygen Concentration Adjustable:40%-90% Process Ventilation·ªT=10min,Infinite recursion ProI:f(150):f(35)=7:3 ProII:f(35):f(150)=7:3 Alarm:Alarm with light and sound for no gas or no power or airway pressure is over Inner Battery:4Ah 12V Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure),HFJV+SIGH(Sigh); Process ventilation I and Process ventilation II, Manual Control Mode.
Feature It is a ventilation device for infant with novel structure and good performance, and chooses opening ventilation mode with high frequency and little tidle volume, so the airway pressure is low.If you want to know more. A. The tidal air can letout with constant pressure, constant current or accurately adjustable flow. B. Opening ventilation, opening intubation makes it not need casing bag, little resistance as expiration is suited for the ventilation management of infant. C. Evident effectiveness of treating ards can be shown with inserting small tube and jetting oxygen through nasal vestibule, which is secure and doesn't cause pressure wound easily. D. Peep and humidifier volume can be adjusted accurately. E. Alarm system with sound and light when no oxygen, poor of electric quantity or low airway positive pressure. F. Heated humidifier can be used for good effectiveness of humidifying. G. Accumulator jar, it can be used while being charged and can last for more than four hours. Specifications Frequency10+150 breaths/min I/e ratio1:1, 1:1.5+ 1:3 and inverse ratio Pressure atomizer rate>=6ml/h Process ventilationt=10min, Proi:f(150):f(35)=7:3 Proii:f(35):f(150)=7:3 Storage battery4ah, automatic charge when 12v Sigh:3breaths/min Alarm:alarm when battery voltage is lower than 11v, alarm lasts 6 seconds if no oxygen, alarm with audible signals and flashing light when the airway pressure is over 0.8kpa Cpap0+0.5kpa Peep0+0.20kpa Oxygen concentration adjustable:21%-90% Jetting volume rangeo+600ml/time Ventilation mode:hfjv(high frequency jet ventilation);cpap(continuous positive airway pressure);hfjv+peep(positive end-expiratory pressure), hfjv+sigh(sigh), process ventilation i and process ventilation ii. Standard packaging.
Feature It is widely used for clinical salvaging and revival also is a dedicated device used for respiration salvaging on emergency ambulance. A. An opening system is designed to avoid leakage of airway, when ventilating, the intubations may have no casing bag. Little tube may be used for ventilation when resistance of expiration is small, so that mucose won't be hurt easily. B. Airway is open during ventilation, suction and ventilation can be done synchronously, so good effectiveness of oxygen combination can be shown without inspiration and expiration synchronizing. C. Lower airway pressure is good to increase blood discharge and decrease encephal pressure. D. Suction device, its driving negative pressure is adjustable. E. Accumulator jar, it can be used continuously for not less than four hours after being charged. F. The system disposes completely with laryngoscope, inlet intubation, catheter of tracheotomy, nasal prongs tube, and air tube etc. Specifications Frequency: 10 150 breaths/min I/e ratio1:1, 1:1.51:3 and inverse ratio Sigh:6breaths/min, Cpapf1.5kpaff Suction negative pressure:-0.050mpa Driving pressure 00.15mpa Constant volume ventilation: t=10min, i/e=1:1.5 Adults:f(100):f(20)=7:3, tidal volume=550ml/time, driving pressure=0.06mpa Children:f(100):f(20)=7:3, tidal volume=350ml/time, driving pressure=0.04mpa Storage battery:4ah, automatic charge when 12v Most jetting volume:f1400ml/time Oxygen concentration adjustable:40%-90% Alarm: alarm when battery pressure is lower than 11v; alarm when the oxygen pressure is lower than 0.01mpa; alarm with sound and light when no gas Ventilation mode:hfjv(high frequency jet ventilation);cpap(continuous positive airway pressure), hfjv+sigh;constant volume ventilation. Standard packing.
Feature A. The device adopts impulse jet oxygen feeding technique with great flow rate of oxygen feeding in a shot while, when feeding oxygen, it adopts change mode major in reflux and many kinds of gas flow mechanism such as convection, laminar flow, sheet flow and so on concurrently, which is good to increase partial pressure of oxygen rapidly, at the same time fluctuation of thorax caused by increasing oxygen flow into airway is good to let out co2. B. Jet oxygen feeding is supported by pressure when inspiration and secure certain peep effect when feeding oxygen, so as to reach good effectiveness of oxygen feeding. C. Accumulator jar, it can be used while being charged and can last for four hours after having been charged. D. Alarm system with sound and light when lack of electric quantity or airway pressure. E. 300cg chooses digital display of import pressure sensor. F. 300cg has three kinds of airway limited pressure alarm for adult, child and infant. G. The device disposes pressure humidifier which has good humidigying effectiveness. Specifications Power supply:ac220v+22v 50hz+1hz I/e ratio1:1, 1:1.5+ 1:3 and 3:1 Driving pressure 0+0.15mpa Sigh:6breaths/min, i/e=1:4 Pressure regulator limit:0.30mpa Cpapnot less than 1kpa Oxygen concentration adjustable:40%-90% Process ventilationt=10min, infinite recursion Proi:f(150):f(35)=7:3 Proii:f(35):f(150)=7:3 Alarm:alarm with light and sound for no gas or no power or airway pressure is over Inner battery:4ah 12v Ventilation mode:hfjv(high frequency jet ventilation);cpap(continuous positive airway pressure), hfjv+sigh(sigh); process ventilation i and process ventilation ii, manual control mode. Standard packing
A. When the ventilation technique with open high frequency and low humidify volume is adopted, the airway pressure is low with little effect of oxygen compound is good and the oxygen partial pressure can be increased rapidly. While the one with regular frequency and great humidify volume is adopted, CO2 can be ejected easily. B. Convenient connecting, it can be connected through the nasal and endotracheal tube. C. The ventilation mode with high frequency and low humidify volume will not easily produce pressure hurt. D. The effect of oxygen dispersion is so good that the tested beastie can stand for a long time. E. Adjustable oxygen concentration, the ventilation mode with continuous oxygen stream and good humidifying effect can ensure beastie to respire independently. F. Be fit for manual ventilation test for monkey, rabbit, dog etc. G. Configured with multiform ventilation conduit for beastles or connected with gas source, in addition. Specifications·ª Frequency:8f+150 breaths/min I/E ratio·ª1:1f+1:3 and inverse ratio Driving Pressure ·ª0f+0.08MPa Gas source: High-pressure oxygen source or air compredsor. The input pressure is not more than 0.16MPa High-pressure gas source:0.16MPa Output Limit of reductor: not less than 0.16MPa Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure),Manual Control Mode.
Fuel LPG. Fuel Tank Capacity 2.0 L Fuel Consumption : App. 225 g P/H Length : 350 mm Height : 330 mm Width : 150 mm Weight(kg) Empty : 1.5 Kg (Empty)
3ply face mask comfortable for user. The face mask is latex free and use brand new hypoallergenic material, odourless and lint free. Product Disposable 3-Ply Non-Woven Face Mask with Ear Loop Size 18cm x 9.5cm (18cm after expended) Color Blue/Green/White/Yellow/Pink or can be customized Outer Layer Spund-bound PP Nonwoven: 20 - 25 gsm Filter Medium Meltblown PP Nonwoven: 18 - 20gsm Inner Layer Lint free ES Nonwoven: 25 gsm Nose Piece Aluminum Packaging 50 pieces per box or 50pcs per bag; 10 boxes/bags per carton. 1600 cartons/20 ft container , 3200 carton/40 HQ container. MOQ 50,000 pieces min order Quantity: 10,000PCS/Day MOQ : 10,000 pieces Packaging: 50 pieces per box/bag; 40 boxes per carton. Payment condition: TT Shipping Duration: 7 Days ( ONE WEEK) Origin: Thailand/China Condition: Subject to availability
Product Name Fashion Consumable Personal Protection Particulate N95 Mask Material Non woven fabric+ Melt Blown Filter+ Non Woven Fabric Shape Molded Cup/Cone Application Farm buildings, Mining, Weaving,Polishing,Pharmacy,Hardware,Cement Size 190*130mm Carton size 310*200*145mm Packing details 50pcs/Carton Product's details Adjustable aluminum nose clip to offer better fit
Non-Sterile Medical Examination Nitrile Gloves Powder free & Latex free 100% Virgin raw materials with FDA certificate & as per ASTM D6319/ CE EN 455 Quality standard: ASTM D6319, with 510K and FDA, CE/EN455, Color: Blue, white Finger Tips: textured Cuff: Beaded Pcs per Box for S/M/L/XL : 100pcs/box Origin: China, Vietnam, Thailand, Malaysia Benefits Protection from unwanted and harmful substances Beaded Cuff ensures easy donning and prevent roll down Superior Strength with better Puncture resistance Finger Tip Textured enhances wet and dry grip Thinner Guage improves tactile senstivity Custom Design enhances comfort and fit Provide an Alternate Solution for individual who are allergic to natural rubber latex Material : Synthetic Nitrile Type : Non-Sterile Powder Free, Amibidextrous, Finger Tip Textured, beaded cuff. Storage: Store in a dry and cool place, the temperature not higher than 38�° C Shelf life: 2 years Physical Properties Tensile Strength: Before Aging 14Mpa min Tensile Strength: After Aging 14Mpa min Elongation at Break (%): Before aging 500% min Elongation at Break (%): After aging 400% min Length: 230 mm in XS, S, M, L, XL Width: 70+/- 10 (XS) Width: 80+/- 10 (S) Width: 95+/- 10 (M) Width: 110+/- 10 (L) Width: 120+/- 10 (XL) Thickness Single wall ( mm): Fingers 0.050mm min Thickness Single wall ( mm): Palm 0.050mm min