200W UHF DTV Transmitter Main features: Wide-band frequency:(470-862MHz) Low noise and power consumption Extremely low group delay Stable constant power output from ALC Output VSWR detection protection Suitable for DTV transmission system with single or multiple channels Widely used in transmission of HFC,AML or MMDS TV signals wireless DTV networking at a lower cost Modular design faciliates installation and maintenance Automatic and manually operated switching backup system available Embedded lightning protector to avoid lightning overvoltage and instant overvoltage Local monitoring and control Wireless remote monitoring(optional) Technical specification: Frequency range:470-860MHz Input signal level:87-117 Noise figure:3db Digital average output power:53dbm Power Consumption:1 KW Power Supply Connector: IEC320 Cooling System Temperature-controlled forced air cooling Operating Temperature Range:0 ~ +45¡ãC Operating Humidity:0 ~ 95%, non-condensing Storage Temperature:-55 ~ +85¡ãC Storage Relative Humidity:0 ~ 95%, non-condensing. Size(W'H'D)/Weight:620mmX810mm X960mm /120kg Package:plywood.
400W UHF TV transmitter Main features: Wide-band frequency:(470-862MHz) Low noise and power consumption Extremely low group delay Stable constant power output from ALC Output VSWR detection protection Suitable for DTV transmission system with single or multiple channels Widely used in transmission of HFC,AML or MMDS TV signals wireless DTV networking at a lower cost Modular design faciliates installation and maintenance Automatic and manually operated switching backup system available Embedded lightning protector to avoid lightning overvoltage and instant overvoltage Local monitoring and control Wireless remote monitoring(optional) Technical specification: Frequency range:470-860MHz Input signal level:87-117 Noise figure:3dB Digital average output power:56dBM Power Consumption 2 KW Power Supply Connector IEC320 Cooling System Temperature-controlled forced air cooling Operating Temperature Range 0 ~ +45¡ãC Operating Humidity 0 ~ 95%, non-condensing Storage Temperature -55 ~ +85¡ãC Storage Relative Humidity 0 ~ 95%, non-condensing Size(W'H'D)/Weight 620mm X1020mm X 960mm /180kg. Size(W'H'D)/Weight 620mm X1020mm X 960mm /180kg Package:Plywood.
Wide-band frequency:(470-862MHz) Low noise and power consumption Extremely low group delay Stable constant power output from ALC Output VSWR detection protection Suitable for DTV transmission system with single or multiple channels Widely used in transmission of HFC,AML or MMDS TV signals wireless DTV networking at a lower cost Modular design faciliates installation and maintenance Automatic and manually operated switching backup system available Embedded lightning protector to avoid lightning overvoltage and instant overvoltage Local monitoring and control Wireless remote monitoring(optional). Technical specification: Frequency range:470-860MHz Input signal level:87-117 Noise figure:3 Digital average output power:59 Power Consumption 5 KW Power Supply Connector IEC320 Cooling System Temperature-controlled forced air cooling Operating Temperature Range 0 ~ +45¡ãC Operating Humidity 0 ~ 95%, non-condensing Storage Temperature -55 ~ +85¡ãC Storage Relative Humidity 0 ~ 95%, non-condensing Size(W'H'D)/Weight 620mm X1400mm X960mm /260kg. Size(W'H'D)/Weight 620mm X1400mm X960mm /260kg Package:Plywood.
1600W UHF DTV transmitter Main features: Wide-band frequency:(470-862MHz) Low noise and power consumption Extremely low group delay Stable constant power output from ALC Output VSWR detection protection Suitable for DTV transmission system with single or multiple channels Widely used in transmission of HFC,AML or MMDS TV signals wireless DTV networking at a lower cost Modular design faciliates installation and maintenance Automatic and manually operated switching backup system available Embedded lightning protector to avoid lightning overvoltage and instant overvoltage Local monitoring and control Wireless remote monitoring(optional). Technical specification: Frequency range:470-860MHz Input signal level:87-117 Noise figure:3 Digital average output power:62 Power Consumption 10 KW Power Supply Connector IEC320 Cooling System Temperature-controlled forced air cooling Operating Temperature Range 0 ~ +45¡ãC Operating Humidity 0 ~ 95%, non-condensing Storage Temperature -55 ~ +85¡ãC Storage Relative Humidity 0 ~ 95%, non-condensing Size(W'H'D)/Weight 620mm X1400mm X960mmX2 /260kgX2. Size(W'H'D)/Weight 620mm X1400mm X960mmX2 /260kgX2.
Long battery life. By stand-by mode, battery lasts 1000h. Power switch remotely controllable. You can control on/off of rcs-50 by rcs-20t. Controllable range is nearly 100m. Original code between rcs-50 (transmitter) and rcs-20t (remote controller) avoid interference with the other unit if someone use it in the same area. bug detectors can not detect sleeping transmitter. (RCS-50) Size... 67 x 21 x 70 (73)mm / antenna °3 x 220mm Weight... 162g (with alkaline batteries) / antenna 3g Power supply... "006p" (6f22/6lr61) 9v battery x 1 Battery life... Approx. 62h (6lr61, continuous transmission) / approx. 1000h (stand-by mode, no transmission) Available channels... Uhf-a, uhf-b Mic effective range... 15m from circle point. (RCS-50) Size... 42.5 x 21 x 112 (120) mm / rod antenna 20mm (shortened) - 460mm (extended) Weight... 162g (with alkaline batteries) / antenna 3g Power supply... "006p" (6f22/6lr61) 9v battery x 1 Battery life... Approx. 11h (6lr61, continuous transmission) Controlling rcs-50... Keep pressing button 5 seconds to turn on rcs-50. Same procedure to turn it off. Rcs-20t uses vhf frequency for remote control.
BROTEK India has all in one, universal, intelligent RF admittance microwave level switch, microwave field generate alarm when measuring point inserting few millimeters in to the medium, also its not effect by foam condensate and residue, by using microwave measuring principle possible to detect a conductive and non conductive medium from: liquid, solid and solid powder. Output of switch only when measuring point is completely cover by medium, also its measuring point has no dead end and is hygienic so level switch is suitable for CIP (Clean-in-Place), WIP (Wash-in-Place) and SIP (Sterilization-in-Place), available with different process connection as per industries requirement, and different temperature version for set up to 200 deg C
Differential Transmitter In All Brand Emerson , Rosemount , Honeyweel , F+h , E+h Etc
Pressure Transmitter for Sandvik LH307/LH410
Notice 1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse. 2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface. 3. The wiring should be strictly in accordance with the instructions of our company. 4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument. 5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds. 6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct. 7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse. 8.The quality assurance period is 12 months. Intelligent Operation Method 1. LCD shows the output percentage or process pressure. Press the S key to select the display percentage or pressure.Press Z key to select pressure unit KPa or Mpa when displaying pressure. 2. Press S+Z key for 8 seconds, then release it at the same time, press Z key to set the zero value; Press the S key set the range. note: this function can only be triggered once an operation. 3. Adjustments to zeros or ranges may cause changes in the displayed options, i.e.The percentage being displayed becomes pressure or KPa becomes Mpa, etc. All these changes are shown only in the display, and have no effect on the internal parameters of the transmitter, pressure detection and current output. After adjusting the zero point and range, the S and Z keys can be used to select the desired percentage or pressure. 4. Zero-setting in field pressure-free state: 30 seconds after pressing S+Z key, the display shows zero time at the same time release the two keys, that is, zero. Simulated operation method 1.Zero-setting in pressure-free condition: The potentiometer with the word "zero" on the circuit board is adjusted to zero when it is displayed on the spot.(Note: Clockwise increase, counterclockwise decrease) 2.The potentiometer marked "range" on the circuit board can not be adjusted without standard pressure, so as to avoid the disorder of measurement range.