Tianjin New Ventech Electronic co.,LTD was established in 1993, which is a professional China manufacturer on variety electronic transformer including coil inductors, PCB mount transformer, toroidal transformer ,high voltage transformer etc. Now we have more than 800 staff, in which there are nearly 60 technical engineers, and 80% have more than 20 years experiences. With continuous hard work, our r&d department researched 8-10 kinds new products averagely every year, and now we have strength to custom-made as per your demand.Our products include: 1.Toroidal transformer 2.PCB mount transformer 3.Common mode choke. 4. Switching transformers 5.low frequency transformer 6.high frequency transformer 7.high voltage transformer We are certified of RoHS, UL, CE environmental protection standard, ISO9001: 2000, ISO14001: 2004 and ect. We offers high quality products with the most competitive price. It is our company's basic of success. The operation idea of our company is do everything we can, satisfy customers'need. Under working hard in this principle, we become a popular manufacturer by customers, investors, and partner company.This site is constantly being updated. If the information you require is not shown please contact us directly. The size of the pallet is 80*120mmm carons on the pallet.
First of all, we are a full-service company located in Hillsboro OR USA. We have at this time 2 brand new high Voltage transformers for sale. Please reply if you are interested and you need more information. Thanks in advance, Daniel.
First of all, we are a full-service company located in Hillsboro OR USA. We have at this time 2 brand new high Voltage transformers for sale. Please reply if you are interested and you need more information. Thanks in advance, Daniel.
Low, medium and high voltage transformers 110kV Class Power Transformers General The110kV class low loss transformers are developed by Huapengour workshop through years of service experience and careful analysis of the advantages and disadvantages of the transformers of different manufacturers, both domestic and abroad, and are featured by low loss, low partial discharge, low noise, high strength against short circuit, and high reliability in service. Its outstanding performance has won high reputation throughout China, and the world, and are highly appreciated by experts of the circle. Transformers can be made with welded tank cover and/or flange , Thus obviated from the necessity of lifting out the active part for inspection after arrival on site. Partial discharge level: apparent discharge < 80pC at 1.5 times rated voltage. Noise level : below 58 dB for transformers 63MVA and below with AN cooling Losses: no-load loss 30% lower than specified by GB/T 6451-1995 Reliability: no damage or oil leakage have been found in transformers in service up to the present Short-circuit withstand capability: Our SZ9-31500/110,SSZ-50000/110 transformers successfully passed short-circuit test in National Transformer Quality Inspecting and Testing Center, and in CESI Laboratory of Italy. Winding 1. Partially interleaved continuous winding is used for HV winding to improve its behavior under lightning impulse, because of its more uniform voltage distribution. 2. All the spacers and vertical strips are rounded at corners, in order to obtain a more reliable insulation structure. 3. Zig-Zag directional flow is provided inside the windings, so that all parts of the windings are better cooled, resulting in lower winding temperature rise, and specifically lower hot-spot temperature, thus the insulation life of the transformer is prolonged. 4. Separate regulating windings are provided for both the 110kV high voltage and the 35kV medium voltage side, so that a more balanced ampere-turn is obtained in spite of tap-changing, the short-circuit withstand capability is thus promoted. Radially, the windings of a phase assembly are tight-fit, little space is left between the core and the low-voltage cylinder, and between the windings. All the vertical strips and cylinders are thoroughly dried before assembly, so that a tight phase assembly can be finally obtained. Core 1. High permeability grain oriented high quality cold-rolled sheets are used for the fabrication of core. The sheets are cut on automatic cutting line made by Georg Co. of Germany or Soenen Co. of Belgium. The burrs are controlled within 0.02mm. 2. The core is stacked without stacking the upper yoke, the upper yoke sheets are placed into position after the winding blocks are mounted on the core. The joints of the core sheets are mitred 45fpjoint with step-lap. The stacked core is pressed under even pressure and the edge of the sheets are painted with epoxy resin, so that a straight, robust, integral structure is obtained, helping to reduce core loss and noise. 3. Wooden strips are driven into the space between core and LV cylinder. The yoke is kept tightened by epoxy-resin impregnated glass tape, while the lower yoke is pressed against the wall of the lower tank through threaded bolts. The active part of the transformer is in addition kept in position by devices at three places between the upper yoke and the tank cover in such a way that the active part cannot be displaced during transportation.
Pproduct brief introduction AC hipot tester series Testing Transformer is power plants power supply bureau and research institutions and other users to do the AC voltage test basic test equipment by the standards of the State Bureau of Quality Supervision for a variety of electrical products electrical components insulation material dielectric strength test etc. the insulation level assessment of products under the provisions of the voltage insulation defects were found in the sample and measure the ability of over-voltage. AC HV Testing Transformer Classification: There are four kinds of high voltage testing transformer according to the medium points: 1. Oil-immersed high voltage transformer test: large capacity cheap convenient maintenance mainstream products. 2. Inflatable high voltage test transformer : interrupter resistance and light weight. 3. Dry type high voltage testing transformer: light weight light volume can run backward price expensive. 4. Series type high voltage testing transformer: small volume low voltage light weight easy to transport and install.
product brief introduction AC hipot tester series Testing Transformer is power plants power supply bureau and research institutions and other users to do the AC voltage test basic test equipment by the standards of the State Bureau of Quality Supervision for a variety of electrical products electrical components insulation material dielectric strength test etc. the insulation level assessment of products under the provisions of the voltage insulation defects were found in the sample and measure the ability of over-voltage. AC HV Testing Transformer Classification: There are four kinds of high voltage testing transformer according to the medium points: 1. Oil-immersed high voltage transformer test: large capacity cheap convenient maintenance mainstream products. 2. Inflatable high voltage test transformer : interrupter resistance and light weight. 3. Dry type high voltage testing transformer: light weight light volume can run backward price expensive. 4. Series type high voltage testing transformer: small volume low voltage light weight easy to transport and install.
Title goes here. INTRODUCTIONS I- GENERAL CHARACTERISTICS Transformers immersed in insulating fluid with natural self cooling (ONAN), three-phase, 10 - 20 MVA.for indoor or outdoor use, 50/60 Hz, hermetically sealed. II- MANUFACTURING STANDARD The transformers described in this catalogue are designedand tested in accordance to IEC/BSEN 60076 III- RATINGS 30,50, 80,100,125,160, 200,250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500kVA. IV- HIGH VOLTAGE This material is designed for voltages of â?¤ 36 kV. Specific figures are not given for this parameter because of the wide variety of voltagesused. Transformers can be supplied on demand to run at two different primary voltages, the shift between these input voltages has two basic alternatives: with a primary tap changer which can be switched with no load and no applied voltage or by changing terminals under the cover. V- LOW VOLTAGE The secondary voltage under no load is allocated at 400V, 415V, 433V, though other voltages can be supplied on demand. When usage requires two voltages, transformers with two simultaneous voltages can be supplied. In this case the no-load voltages are set to 400V(230V),415V(240V),433V(230V). VI- VECTOR GROUP REFERENCE The connections normally used are as follows: For rated power levels of 160 kVA or less: Yyn0 For rated power levels over 160 kVA: Dyn11. ACCESSORIES I- BASIC EQUIPMENTS All transformers are supplied with: 3 high voltage bushings 4 or 7 low voltage bushings 5-position tap changer on cover, workable with transformer off load 2 lifting & tank removal eye-bolts Filling hole with M-40 x 1.5 outside thread and threaded cover Drainage & sampling plug at bottom of tank Two-way, standard rail gauge welded at the bottom of tank 2 earthing connections at bottom with M-10 screws II- OPTIONAL ACCESSORIES Thermometer Tap changer HV plug-in bushing Thermostat Protection & control block for the following
Title goes here. INTRODUCTIONS I- GENERAL CHARACTERISTICS Transformers immersed in insulating fluid with natural self cooling (ONAN), three-phase, 10 - 20 MVA.for indoor or outdoor use, 50/60 Hz, hermetically sealed. II- MANUFACTURING STANDARD The transformers described in this catalogue are designedand tested in accordance to IEC/BSEN 60076 III- RATINGS 30,50, 80,100,125,160, 200,250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500kVA. IV- HIGH VOLTAGE This material is designed for voltages of â?¤ 36 kV. Specific figures are not given for this parameter because of the wide variety of voltagesused. Transformers can be supplied on demand to run at two different primary voltages, the shift between these input voltages has two basic alternatives: with a primary tap changer which can be switched with no load and no applied voltage or by changing terminals under the cover. V- LOW VOLTAGE The secondary voltage under no load is allocated at 400V, 415V, 433V, though other voltages can be supplied on demand. When usage requires two voltages, transformers with two simultaneous voltages can be supplied. In this case the no-load voltages are set to 400V(230V),415V(240V),433V(230V). VI- VECTOR GROUP REFERENCE The connections normally used are as follows: For rated power levels of 160 kVA or less: Yyn0 For rated power levels over 160 kVA: Dyn11. ACCESSORIES I- BASIC EQUIPMENTS All transformers are supplied with: 3 high voltage bushings 4 or 7 low voltage bushings 5-position tap changer on cover, workable with transformer off load 2 lifting & tank removal eye-bolts Filling hole with M-40 x 1.5 outside thread and threaded cover Drainage & sampling plug at bottom of tank Two-way, standard rail gauge welded at the bottom of tank 2 earthing connections at bottom with M-10 screws II- OPTIONAL ACCESSORIES Thermometer Tap changer HV plug-in bushing Thermostat Protection & control block for the following
S11 SERIES POWER TRANSFORMERS The capacity range of 10kV class S11 full seal power transformer is 30kva-2500kva. In 10kV, 50Hz power transmission and distribution system, it can be widely used in high-rise buildings, commercial centers, subways, airports, stations, industrial and mining enterprises, drilling platforms, especially in places with high fire protection requirements such as inflammables and explosives, and in places with poor environment. It can also be used for power and lighting in residential areas, commercial streets and rural areas. Advantages: S11 type fully sealed oil immersed transformer is the main type selection product of current distribution equipment, with remarkable energy saving effect. The S11 distribution transformer produced by our company uses 30p series high conductivity oriented silicon steel produced by well-known enterprises, and adopts new insulating materials and processes. The products are resistant to high temperature and impact. The integral mailbox composed of corrugated radiator is produced by phosphating and multi-layer antirust spraying technology, which has good weather resistance.
Super High Voltage Transformer Oil Purifier,decolorization,degassing,dehydration machine Untra High Voltage Transformer Oil Treatment Plant Untra High Voltage Transformer Regeneration Recycling Plant Application & Function Ultra-high Voltage Grid is regarded as Electric High Way which features big capacity, distance and low loss. Until now, there are 750KV, 1000KV, 660KV, 800KV direct current in our nation's ultra-high voltage grids. Considering its safety, it has extremely requirement on insulating oil in transformer, mutual inductor and reactor, the ZYD Series Ultra-High Voltage Oil Treatment Equipment, manufactured by our company is effective in particles refining, vacuum degassing and oil-water separation. This equipment has been successfully applied in 750KV alternating current and 800KV key projects. And every oil treatment index reaches the national ultra-high voltage oil purification standard. Transformer oil maintenance is the key to transformer reliability, performance and longevity. Your transformerâ??s insulati Middle Type Vacuum Insulation Oil Recycling Machine ng oil should be free from moisture, dissolved gases and particles that accumulate as the oil ages. Even some new oils may require treatment to limit these contents to acceptable levels. CE ISO Vacuum Transformer Oil Purifier Machine designed to remove contaminants (particulate, water, gasses, acids, etc.). We are a design, engineering and manufacturing company capable of application customization for best solutions. Feature: 1. Especially for removing water from transformer oil, such as free water, trace water and so on by the double stage vacuum system for high voltage oil. 2. Remove gas, air content from the old high voltage transformer oil by vacuum degassing system. 3. Remove impurities, tiny particles, acidity, sludge, free carbon, other soluble oil decay products and discoloration substances by 3 stages of filters (Primary filter, secondary filter, fine filter). 4. Independent vacuum oiling system for transformers, this oil purifier can also vacuum dry transformer and on-line operation with transformers. 5. Designed for processing high voltage insulating oils in workshops, onsite power stations, purifying oil in oil storage tanks or directly in transformers(energized or de-energized transformers). 6. Efficient electric heating system, heating uniformity, less power consumption, safe, and reliable. 7. Double-infrared liquid level sensor, pressure protective system and foaming detecting and eliminating to ensure machine operation easily and safely. 8.Adopt interlocked protective system, which connect oil pump, heater and liquid level sensor, avoiding blank heating, blank pumping. Advantage: High Voltage Transformer Oil Purifier Machine Model ZYD is particularly suitable for filtering high-grade transformer oil, super-voltage transformer oil and new transformer oil. It can be used for filtration of more than 110V substation live line work onsite.
1. Rate voltage:from 145kV to 7.2kV 2. Tpye: transformer bushing for high voltage 3. Marterial:epoxy resin 4. According to IEC,GB. Carton box.
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 100-1500A Rated load â?¤10VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 80x110x50 Weight (kg) 2.1 Operating conditions Operating temperature -35C to +55C Daily average temp
Din hrc "s" type high voltage fuse for transformer protection: 1. According to bussmann din "s" type high performance back-up fuse 2. Comply with iec282-1, din, bs 3. This fuse is intended to protect distribution networks and transformer, for indoor as well as outdoor use. 4. Any other specifications can be designed specially. Type rated voltage (kv) rated current (a) diameter (mm) length (mm) Xrnt1 3.6 6.3 10 16 20 25 31.5 40 51 192 Xrnt1 7.2 6.3 10 16 20 25 31.5 40 50 63 51 292 Xrnt1 7.2 80 100 125 160 76 292 Xrnt1 12 10 16 20 25 31.5 40 51 292 Xrnt1 12 50 63 71 80 100 76 292 Xrnt1 12 125 76 292 Xrnt1 12 160 200 88 292 Xrnt1 24 6.3 10 16 20 25 31.5 40 51 442 Xrnt1 24 50 63 71 80 100 76 442 Xrnt1 24 125 76 442 Xrnt1 24 160 88 442 Xrnt1 40.5 3.15 6.3 10 16 20 25 51 537 Xrnt1 40.5 31.5 40 76 537 Xrnt1 40.5 63 88 537 3pcs a carton
1.Operating temperature range:-20 to +45 2.Storage temperature:-40 to 70 3.Switching frequency:1khz to 200khz 4.Withstanding voltage:1500/3750vac for 1 minute between primary and secondary 5.Insulation resistance:500vdc 100m¦¸ miin. Between primary&secondary. As per customer¡¯s requirements
product brief introduction Product Introduction HJ series standard voltage transformers are designed and manufactured for the actual needs of basic power supply and production departments.This product has the advantages of compact structure small size light weight easy to carry and easy to operate without maintenance etc. This product is especially suitable for field use and can also be used as standard voltage transformer and test transformer in laboratory.
HJ series standard voltage transformers are designed and manufactured for the actual needs of basic power supply and production departments.This product has the advantages of compact structure small size light weight easy to carry and easy to operate without maintenance etc. This product is especially suitable for field use and can also be used as standard voltage transformer and test transformer in laboratory. Product nickname, Precision voltage transformer, Calibration voltage transformer Calibrating voltage transformer Standard voltage transformer for calibration PTstandard standardPT High precision voltage transformer high precisionPT
product brief introduction Product Introduction HJ series standard voltage transformers are designed and manufactured for the actual needs of basic power supply and production departments.This product has the advantages of compact structure small size light weight easy to carry and easy to operate without maintenance etc. This product is especially suitable for field use and can also be used as standard voltage transformer and test transformer in laboratory. Product nickname voltage transformer Calibration voltage transformer voltage transformer Standard voltage transformer for calibration PTstandard standardPT High precision voltage transformer high precisionPT
High voltage transformers.
Transformers,Distribution and Power Transformer,Varivolt Safety Transformers Diesel Generators Industrial Panels Stabilizers Energy Saver Industrial Panels