S11 SERIES POWER TRANSFORMERS
The capacity range of 10kV class S11 full seal power transformer is 30kva-2500kva. In 10kV, 50Hz power transmission and distribution system, it can be widely used in high-rise buildings, commercial centers, subways, airports, stations, industrial and mining enterprises, drilling platforms, especially in places with high fire protection requirements such as inflammables and explosives, and in places with poor environment. It can also be used for power and lighting in residential areas, commercial streets and rural areas.
Advantages:
S11 type fully sealed oil immersed transformer is the main type selection product of current distribution equipment, with remarkable energy saving effect. The S11 distribution transformer produced by our company uses 30p series high conductivity oriented silicon steel produced by well-known enterprises, and adopts new insulating materials and processes. The products are resistant to high temperature and impact. The integral mailbox composed of corrugated radiator is produced by phosphating and multi-layer antirust spraying technology, which has good weather resistance.
Transformers,Distribution and Power Transformer,Varivolt Safety Transformers Diesel Generators Industrial Panels Stabilizers Energy Saver Industrial Panels
Tianjin New Ventech Electronic co.,LTD was established in 1993, which is a professional China manufacturer on variety electronic transformer including coil inductors, PCB mount transformer, toroidal transformer ,high voltage transformer etc. Now we have more than 800 staff, in which there are nearly 60 technical engineers, and 80% have more than 20 years experiences. With continuous hard work, our r&d department researched 8-10 kinds new products averagely every year, and now we have strength to custom-made as per your demand.Our products include: 1.Toroidal transformer 2.PCB mount transformer 3.Common mode choke. 4. Switching transformers 5.low frequency transformer 6.high frequency transformer 7.high voltage transformer We are certified of RoHS, UL, CE environmental protection standard, ISO9001: 2000, ISO14001: 2004 and ect. We offers high quality products with the most competitive price. It is our company's basic of success. The operation idea of our company is do everything we can, satisfy customers'need. Under working hard in this principle, we become a popular manufacturer by customers, investors, and partner company.This site is constantly being updated. If the information you require is not shown please contact us directly. The size of the pallet is 80*120mmm carons on the pallet.
First of all, we are a full-service company located in Hillsboro OR USA. We have at this time 2 brand new high Voltage transformers for sale. Please reply if you are interested and you need more information. Thanks in advance, Daniel.
First of all, we are a full-service company located in Hillsboro OR USA. We have at this time 2 brand new high Voltage transformers for sale. Please reply if you are interested and you need more information. Thanks in advance, Daniel.
Low, medium and high voltage transformers 110kV Class Power Transformers General The110kV class low loss transformers are developed by Huapengour workshop through years of service experience and careful analysis of the advantages and disadvantages of the transformers of different manufacturers, both domestic and abroad, and are featured by low loss, low partial discharge, low noise, high strength against short circuit, and high reliability in service. Its outstanding performance has won high reputation throughout China, and the world, and are highly appreciated by experts of the circle. Transformers can be made with welded tank cover and/or flange , Thus obviated from the necessity of lifting out the active part for inspection after arrival on site. Partial discharge level: apparent discharge < 80pC at 1.5 times rated voltage. Noise level : below 58 dB for transformers 63MVA and below with AN cooling Losses: no-load loss 30% lower than specified by GB/T 6451-1995 Reliability: no damage or oil leakage have been found in transformers in service up to the present Short-circuit withstand capability: Our SZ9-31500/110,SSZ-50000/110 transformers successfully passed short-circuit test in National Transformer Quality Inspecting and Testing Center, and in CESI Laboratory of Italy. Winding 1. Partially interleaved continuous winding is used for HV winding to improve its behavior under lightning impulse, because of its more uniform voltage distribution. 2. All the spacers and vertical strips are rounded at corners, in order to obtain a more reliable insulation structure. 3. Zig-Zag directional flow is provided inside the windings, so that all parts of the windings are better cooled, resulting in lower winding temperature rise, and specifically lower hot-spot temperature, thus the insulation life of the transformer is prolonged. 4. Separate regulating windings are provided for both the 110kV high voltage and the 35kV medium voltage side, so that a more balanced ampere-turn is obtained in spite of tap-changing, the short-circuit withstand capability is thus promoted. Radially, the windings of a phase assembly are tight-fit, little space is left between the core and the low-voltage cylinder, and between the windings. All the vertical strips and cylinders are thoroughly dried before assembly, so that a tight phase assembly can be finally obtained. Core 1. High permeability grain oriented high quality cold-rolled sheets are used for the fabrication of core. The sheets are cut on automatic cutting line made by Georg Co. of Germany or Soenen Co. of Belgium. The burrs are controlled within 0.02mm. 2. The core is stacked without stacking the upper yoke, the upper yoke sheets are placed into position after the winding blocks are mounted on the core. The joints of the core sheets are mitred 45fpjoint with step-lap. The stacked core is pressed under even pressure and the edge of the sheets are painted with epoxy resin, so that a straight, robust, integral structure is obtained, helping to reduce core loss and noise. 3. Wooden strips are driven into the space between core and LV cylinder. The yoke is kept tightened by epoxy-resin impregnated glass tape, while the lower yoke is pressed against the wall of the lower tank through threaded bolts. The active part of the transformer is in addition kept in position by devices at three places between the upper yoke and the tank cover in such a way that the active part cannot be displaced during transportation.
Pproduct brief introduction AC hipot tester series Testing Transformer is power plants power supply bureau and research institutions and other users to do the AC voltage test basic test equipment by the standards of the State Bureau of Quality Supervision for a variety of electrical products electrical components insulation material dielectric strength test etc. the insulation level assessment of products under the provisions of the voltage insulation defects were found in the sample and measure the ability of over-voltage. AC HV Testing Transformer Classification: There are four kinds of high voltage testing transformer according to the medium points: 1. Oil-immersed high voltage transformer test: large capacity cheap convenient maintenance mainstream products. 2. Inflatable high voltage test transformer : interrupter resistance and light weight. 3. Dry type high voltage testing transformer: light weight light volume can run backward price expensive. 4. Series type high voltage testing transformer: small volume low voltage light weight easy to transport and install.
Spec: Voltage Transformer (Brand: M/S Tianshui Changkai) IL: 12/45/75kV 1Kw, 50Hz, 1.9Un:8h
Title goes here. INTRODUCTIONS I- GENERAL CHARACTERISTICS Transformers immersed in insulating fluid with natural self cooling (ONAN), three-phase, 10 - 20 MVA.for indoor or outdoor use, 50/60 Hz, hermetically sealed. II- MANUFACTURING STANDARD The transformers described in this catalogue are designedand tested in accordance to IEC/BSEN 60076 III- RATINGS 30,50, 80,100,125,160, 200,250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500kVA. IV- HIGH VOLTAGE This material is designed for voltages of â?¤ 36 kV. Specific figures are not given for this parameter because of the wide variety of voltagesused. Transformers can be supplied on demand to run at two different primary voltages, the shift between these input voltages has two basic alternatives: with a primary tap changer which can be switched with no load and no applied voltage or by changing terminals under the cover. V- LOW VOLTAGE The secondary voltage under no load is allocated at 400V, 415V, 433V, though other voltages can be supplied on demand. When usage requires two voltages, transformers with two simultaneous voltages can be supplied. In this case the no-load voltages are set to 400V(230V),415V(240V),433V(230V). VI- VECTOR GROUP REFERENCE The connections normally used are as follows: For rated power levels of 160 kVA or less: Yyn0 For rated power levels over 160 kVA: Dyn11. ACCESSORIES I- BASIC EQUIPMENTS All transformers are supplied with: 3 high voltage bushings 4 or 7 low voltage bushings 5-position tap changer on cover, workable with transformer off load 2 lifting & tank removal eye-bolts Filling hole with M-40 x 1.5 outside thread and threaded cover Drainage & sampling plug at bottom of tank Two-way, standard rail gauge welded at the bottom of tank 2 earthing connections at bottom with M-10 screws II- OPTIONAL ACCESSORIES Thermometer Tap changer HV plug-in bushing Thermostat Protection & control block for the following