1. General HS-SG109 Sound Strobe of notification appliances offers a wide range of Sound/strobes, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems.
Model No. SR-812PC-2 Operating voltage DC9~35V Alarm temperature N/A Static current 20uA Alarm current 35mA@DC12V;83m@DC24V Alarm output Remote LED indicator Installation Ceiling mounted Sensitivity 2.06%ft±1.3%ft Working environment -10~+50(â?¤95%RH No congelation) Dimension 100*46mm
The 640 addressable audio/visual alarm devices are suitable for connection to 2-wire addressable fire detection And alarm systems. 640 is loop-powered and activation is initiated by a dedicated initiation message from the control and indicating Equipment. Up to 125 devices can be connected to each alarm zone loop. Visual, audible and audio/visual models available Red or white body available for audible alarm device Loop-powered from control and indicating equipment Operates when a dedicated activation message is received from the control and indicating equipment Loud sounder output of 85 db at 1 m Long-life leds Low quiescent current Dip switch address setting
1. General Conventional Fire Alarm Control Panel with four Zones 2. Specifications Two Style B (Class B) Initiating Device Circuits (IDCs). All zones accept two-wire smoke detectors and any normally-open contact devices. One built-in Fire Fighting Ouput. 24-volt operation. Resettable four-wire smoke detector power 500 mA. Non-resettable power 500 mA. One-man walk-test programmable for silent or audible test. Disable/Enable control per IDC. Reverse polarity protection. 3. Packaging and shipping Conventional Fire Alarm Control Panel with four Zones 1 pc/carton box;carton M:43*17*51cm
1. General HS-JL188-6 Electric bell of notification appliances offers a wide range of Sound, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems. 2. Specifications Name 6" Alarm Bell Item No. HS-JL188-6 Operating voltage DC24V Alarm current 70mA @ DC24V Alarm sound intensity Minimum 95dB Dimension Diameter 155mm, height 45mm Weight 650g Features Easy to install bracket 3. Features Operating Voltage : DC24V Alarm Current: Maximum 70 mA Alarm Sound Intensity: Minimum 95dB
Conventional fire fighting control panel with 4 zones and 3 sound output, designed to connect with 2/4 wired smoke detector, heat detector, manual call point, manual release, gas release lamp etc. 1. Specifications a. Four Style B (Class B) Initiating Device Circuits (IDCs). b. All zones accept two-wire smoke detectors and any normally-open contact devices. c. One built-in Fire Fighting Ouput. d. 24-volt operation. e. Resettable four-wire smoke detector power @ 500 mA. f. Non-resettable power @ 500 mA. g. One-man walk-test programmable for silent or audible test. h. Disable/Enable control per IDC. i. Reverse polarity protection.
The device is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response. It is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance and is used in high hazard applications such as petrochemical plants, munitions factories and other areas where flammable or explosive liquids or solids are handled or stored. The flame sensor adopts an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust-resistant, corrosion proof and moisture-resistant, therefore is not sensitive in sunlight, dust, oil, tolerance of fume, and humidity. Set in a standard calibration to detect a flames at a distance of 25 meters, which flame created by 2Kg ethanol in a Container of Base 33cmX33cm, Height 5cm.
Fire exstinguishers fire hydrrant fire sprinker fire alarm system fire bucket fire ball fire fire door.
1. Current overload or line surge shutdown 2. High temperature compressor shutdown. 3. High pressure alarm shutdown. 4. Low pressure alarm shutdown. 5. Low oxygen cocentrator alarm. Oxygen concentrator: 0.5-5L/min Purity: 95%+_3% Working system Continuous Power Supply AC230V.50Hz/AC220V.60HZ AC120V.60Hz Power: 390VA Net Weight: 16kg( Gross weight: 18.5kgs) Warranty: Long-life compressor designed for 1000 hours of maintenance-free use. Size: 33*26*54cm
The FK-5-1-12 Clean Agents, also known as NOVEC1230 Fire Suppression Agents, is a highly efficient and reliable hydro-fluorocarbon fire extinguishing solution. This product is designed to quickly and effectively suppress fires in various settings while being non-toxic, environmentally friendly, and safe to use. Model Number: FK-5-1-12 clean agents Product Name: NOVEC1230 Fire Suppression Agents Reliability: High Model NO.: FK-5-1-12 clean agents Application The FK-5-1-12 Clean Agents is suitable for use in various applications, including but not limited to: Commercial buildings Industrial facilities Data centers Telecommunication rooms Museums and art galleries Power generation plants Server rooms Control rooms Storage facilities
We supply 25mm, 26mm Plain Particle Boards for filling inside the doors. 2440x1220x26mm plain particle board shall weigh about 40kgs. We do particle board starting 9mm to 40mm and above for various purposes like lamination grade fully sanded on both faces, for routing purpose, furniture backing etc. 26mm(non sanded) :520Kg/m3 - E2 Grade 30 to 64mm- E1, High Moisture Resistance, Both Sides sanded 26mm(non sanded) :520Kg/m3 - E2 Grade 30 to 64mm- E1, High Moisture Resistance, Both Sides sanded, suitable for Fire door -tested to BS standard We can also adjust the density of board as per our customer requirement. Our plain particle boards are priced competitive. Please contact us for more details.
Product categories of Sensor Type of Fire Alarm, we are specialized manufacturers Sensor Type Of Fire Alarm, Sensor Type Fire Alarm suppliers/factory, wholesale high-quality products of Fire Alarm Sensor Type R & D and manufacturing, we have the perfect after-sales service and technical support. Look forward to your cooperation Here you can find the related products in Sensor Type of Fire Alarm, we are professional manufacturer of Sensor Type Of Fire Alarm,Sensor Type Fire Alarm,Fire Alarm Sensor Type,Fire Alarm. We focused on international export product development, production and sales. We have improved quality control processes of Sensor Type of Fire Alarm to ensure each export qualified product. If you want to know more about the products in Sensor Type of Fire Alarm, please click the product details to view parameters, models, pictures, prices and other information about Sensor Type Of Fire Alarm,Sensor Type Fire Alarm,Fire Alarm Sensor Type,Fire Alarm. Whatever you are a group or individual, we will do our best to provide you with accurate and comprehensive message about Sensor Type of Fire Alarm
Smoke detector, heat detector, flame detector, beam detector, gas detector, fire alarm control panel, manual call point, sounder strobe, fire alarm system.
Smoke, heat, gas, co detectors alarm, conventional, addressable fire alarm control panel, sounder.
High alumina bricks, fire bricks, fly ash bricks, turmeric powder, lemon, ginger, caustic soda, towel, kids garment, shoe.
Specifications:- * Control key switch * Mains healthy indicator * Continuous alarm signal * Built-in battery * Polarity protection for battery * Push buttons for Evacuate, Reset and Alarm silence * Monitored alarm circuits for both open and short circuit * Individual sounder circuits for zones (optional) * Indicators for charger fault and battery fault * All controls are on front fascia * Knockouts on top and bottom sides for easy installation * Main supply - 240 V AC +/- 10%, 50/60 Hz * Battery supply - 24 V DC (Sealed Lead Acid) * Glass fuse protection - Main supply, Charging voltage, Sounder circuit, Reserve battery connection * Auxiliary relay contacts -30 V DC, 1 A, NO/NC
The mini 2 zone panel HS-CK1002 have Master panel and Slave panel. One Master panel can connect 31 Slave panel, and the Master panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault. 2. Specifications Item No. HS-CK1002 HS-CK1004 HS-CK1008 HS-CK1016 Zones 2 4 8 16 Sound output 1 1 2 4 AC power 220VAC/50Hz 220VAC/50Hz 220VAC/50Hz 220VAC/50Hz Battery Sealed lead-acid only Total DC24V system power 3.0 amps Max current per NAC 1.25amps Max battery charging capability 18AH Cabinet weight(net/gross) 3.5/4kg w/o battery 6.0/6.6kg w/o battery 6.0/6.6kg w/o battery 6.0/6.6kg w/o battery 3. Features our Style B (Class B) Initiating Device Circuits (IDCs). One Master Panel also has two zones, each zone can connect max.25 conventional detectors. One slave Panel has two zones, each zone can connect max.25 conventional detectors. The Mater panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault.