The initial magnetic permeability and temperature stability between nanocrystalline soft magnet alloy and permalloy are similar. Under the same conditions of core sizes and characteristics, the weight of the former is much lighter (about 1/3 lighter), cost much lower. Applications: Electronic kwh meter Precise power meter Overcurrent protection in mechanical control apparatus Current control in industrial automation Good thermal stability Paper ctn
Application Current transformers can convert large currents into small currents in a certain proportion, thereby providing current for various instruments and relay protection, and isolating the secondary system from high voltage. This way can protect workers and equipment, can also simplifies and standardizes the manufacture of meters and relays. Advantagesï¼? In order to improve the current transformer precision, has to improve the magnetic permeability of current transformer cores. Compared with silicon steel core, nanocrystalline core has better magnetic permeability. Compared with permalloy core, the cost of nano core is lower. So nano core is the ideal material of current transformer. It is widely used in precision current transformer, zero sequence current transformer, medium and high frequency transformer.
Application Current transformers can convert large currents into small currents in a certain proportion, thereby providing current for various instruments and relay protection, and isolating the secondary system from high voltage. This way can protect workers and equipment, can also simplifies and standardizes the manufacture of meters and relays. Advantages In order to improve the current transformer precision, has to improve the magnetic permeability of current transformer cores. Compared with silicon steel core, nanocrystalline core has better magnetic permeability. Compared with permalloy core, the cost of nano core is lower. So nano core is the ideal material of current transformer. It is widely used in precision current transformer, zero sequence current transformer, medium and high frequency transformer.
Detailed Product Description 1. Manufactory and trading company 2. Stable product performance 3. Plywood containers 4. Offshore delivery within 10 days Performance characteristic: Has a high saturation flux density, pulsed magnetic permeability, low core loss, coercive force, frequency range in the 1 ~ 100 KHz. Application: High-power switching power supply and inverter welding inverter power transformer UPS uninterruptible power supply Communications equipment High frequency induction Heating power supply Charging power supply 40/65*15 40/65*25 40/70*25 40/73*30 40/75*40 40/78*25 40/85*30 41.5/47.5*5 41/77*36 42/65*30 42/68*35 42/70*30 42/72*25 42/73*38 43.5/53.5*5 43.5/53.5*8 43/49*10 43/57*15 43/57*8 43/58*5 44/52.2*6.5 44/66*30 44/68*20 44/69*30 44/80*45 44/90*50 45/55*40 45/60*20 44/76*18 44/78*38 45/62*26 45/63*25 45/65*30 45/67*26 45/68*25 45/75*20 45/75*35 45/78*30 45/85*50 46.5/63*15 46/55*16 46/63*35 46/66*25 46/66*35 46/74*26 47/58*15 47/58.2*12 47/65*26 48/78*30 48/78*40 48/85*35 48/91*35 49.9/61.8*5.5 50/100*25 50/100*25 50/105*45 50/60*10 50/60*8 50/60*9 50/65*25 50/65*8 50/67*35 50/75*25 50/75*25 50/80*10 50/80*15 50/80*25 50/80*25 50/90*30 50/90*30 51/64*26 52.5/60*6.5 52.5/61*6.5 52/62*8 53/64*10 54/60*6.5 54/62*10 54/80*25 55/62*5 55/65*10 55/69*30 56/70*25 57.5/65*7.5 58/78*30 58/82*30 59/70*25 60/120*30 60/120*30 60/75*25 60/80*16 60/80*30 60/90*20 61/69*10 61/69*5 61/70*10 61/70*20 61/70*20 62/71*8 62/78*30 64/75.2*5 64/77*4 64/78*30. Wooden case+carton box.
Transformer core
KF series split-core current transformers. The CT can be mounted to existing panels, such as control centers or load centers, to measure or monitor voltage. These CTs can be mounted without removing existing cables for easily installation.
Features: High saturate magnetic induction bs High initial permeabilityhigh linearity high accuracylow phase and amplitude error for ct Good temperature stability-55~130 Applying for transformer class grade: 0.5-0.05 class 2applications High precision current and voltage transformer Current leakage circuit breakers Electronic watt hour meter Precision power meter Current control in automation industry
DAQGPCT485 split core current transformer is a kind of current sensor transformer which can convert AC analog signal into RS485 digital signal launched by Shanghai Data Acquisition IOT Technology Co LTD The product has builtin 32bit ARM series MCU and highprecision metering chip and is a multipoint calibrated current conversion module It has the characteristics of high precision and fast response DAQGPCT485 can directly interact with common data acquisition gateways DTU programmable controller PLC and host computer This product is widely used in AC motor lighting equipment air compressor heating ventilation and air conditioning equipment building selfcontrol system equipment OEE open rate industrial Internet rural power transformation projects and other scenarios of current monitoring and acquisition scenarios 2 Service Concept Our company solemnly promise you You buy more than just products but also meticulous and thoughtful technical support We provide free remote guidance remote configuration and commissioning services and send data to the server specified by the customer Free IOT solution consulting services 3 Product Characteristic Parameters Line Sequence Definition Red12V BlackGND Yellow485A White485B Length of LineDefault 1 meter Acquisition Characteristic Current detection range AC 02A100AOther large range transformers can be customized Electrical Characteristic Power supply mode524V DC Operating power consumption05W Operating frequency5060Hz Communication Characteristic Transmission modeRS485 Communication protocol Modbus RTU Structural Characteristic MaterialABS plastic housing Installation methodBuckle mounting Working Environment Temperature 20C70C Storage Environment Temperature 20C80C 4 The Core Advantages of the Product High precision measuring chip high measurement accuracy Open type design easy to install Easy installation and fast deployment helping IOT projects land quickly 5 Description of the Modbus Communication Protocol 51 Serial Port Communication Parameters Baud rate9600 Data bit8 Verify NONE Stop bit1 52 Function Code Definition The upper computer uses 03 function code to read data or receive alarm data The host computer controls the lower machine equipment transformer using 06 function code
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13 Accuracy Class 0.5S, 0.5%, 1%, 3% Range of primary rated current 100-1000A Range of Rated load 10VA Rated frequency 50/60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 150%I1n Secondary winding power frequency withstand voltage 3kV, 1min Safety Factor Rating (FS)
Application areas: Measuring-level current transformer used in power system, transformer used on precision measuring instruments (such as watt-hour meter). According to the requirements of different measurement accuracy of the transformer, different soft magnetic materials can be chosen as iron core materials. The higher the permeability of the iron core is, the smaller the measurement error of the transformer is, hence the accuracy is higher. At present, the most common iron core material is cold-rolled silicon steel sheet, followed by Permalloy and nano-crystalline glass alloy. In recent years, demands for transformers with high-precision level (such as class 0.2, class 0.2Sand class0.5S) increased rapidly. When small ratio, low ampere turns are required or the iron core is restricted because of the small volume, the cold-rolled silicon steel often fails to meet the accuracy requirements. Although the Permalloy iron cores with high permeability can meet the required precision, its price is very high. However use of nano-crystalline alloy iron cores can both meet the accuracy requirements and be produced at lower cost than the Permalloy. Therefore, the demand of measuring level current transformer iron core made of nano-crystalline alloy rapidly increased domestically. The typical parameters comparison of the common soft magnetic materials used for current transformer iron cores: Basic parameters Nano-crystalline iron core Permalloy (1J85) iron core Silicon steel iron core Saturation magnetic flux density (Bs) 1.25T 0.75T 2.03T Initial permeability (¦Ì0) 8¡«12, 104 5¡«8, 104 103 Maximum permeability (¦Ìm) 60, 104 60, 104 4, 104 Curie Temperature (¡æ) 570 400 740 Density (g/cm3) 7.25 8.75 7.65 Lamination factor 0.7 0.9 0.95 Thickness (mm) 0.03 0.15 0.3 Features: It is made of the iron-based nano-crystalline strips with a moderate saturation magnetic induction, high permeability and low loss, which can effectively reduce ratio difference angle difference of the transformer. The saturation magnetic induction Bs of nano-crystalline alloy is between the silicon steel and Permalloy. The lower the Bs value is, the lower the security coefficient of the instrument is. When the system failure occurs and large current through the current transformer results therefore, the iron core is more easily filled, and the secondary current no longer increases in proportion, as can assure that the secondary instruments are well protected and not to be damaged. Permeability of nano-crystalline alloy is close to Permalloy and a magnitude higher than silicon steel, so it is suitable to be made as high-precision transformer iron core. The density and lamination coefficient of nano-crystalline is lower than that of Permalloy, under the condition of the same size and similar performance of the two. In this case the nano-crystalline iron core is 1/4 lighter in weight, and 1/3 lower in the manufacturing cost. In addition, the linear range of nano-crystalline alloy is wider than that of Permalloy .It can work for a long time at temperature of -55 ~ 130 ¡æ ,with a good temperature stability. Specifications a. Rectangular core: (mm) Iron Core Size(mm) (mm) The case size(mm) Weight of the iron Core (kg per piece) Turns Ratio N1: N2 Excitation current(mA) Excitation voltage(mV) 55*97/77*119, 25 50*92/82*114, 30 0.53 1:1 25 0.45 95 2.2 1500 53 70*90/100*120, 30 65*85/105*125, 36 0.81 1:1 200 15 1:1 500 50 75*95/105*125, 25 70*90/110*130, 30 0.7 1:1 70 2 1:1 175 8 80*95/120*135, 25 75*90/125*140, 30 1.09 1:1 80 1.7 1:1 600 41 90*90/160*160, 30 85*85/165*165, 36 2.4 1:1 100 6 1:1 500 100 1:1 1000 140 135*135/260*260, 10 130*130/265*265, 16 2.3 1:1 100 1.5 1:1 500 32 82*602/138*658, 45 75*595/145*665, 55 8.8 1:1 100 1.2 1:1 1000 45 1:1 2000 120 b. Ring core: No. The iron Core Size Case size(mm) The weight of the iron core (kg per piece) Turns ratio N1: N2 is 1:1; Input current (mA), 50Hz; Output voltage (mV) 1 1105/1165, 15 1095/1175, 25 8.35 Excitation current 450 1200 2000 Excitation voltage 0.59 2.36 5.28 2 415/520, 15 409/526, 23 6.08 Excitation current 50 250 700 Excitation voltage 0.4 3 11 3 305/490, 15 299/496, 23 9.1 Excitation current 350 900 ¡¡ Excitation voltage 5 20 ¡¡ 4 315/395, 35 309/401, 43 8.2 Excitation current 120 400 ¡¡ Excitation voltage 3 11 ¡¡ 5 198/248, 30 192/254, 37 2.76 Excitation current 100 200 500 1000 Excitation voltage 2 6 35 90 6 198/248, 20 192/254, 27 1.84 Excitation current 100 200 500 1000 Excitation voltage 1.5 3.5 25 60 7 155/200, 30 150/205, 36 2 Excitation current 100 190 1000 Excitation voltage 2.5 9.5 80 8 140/180, 30 135/185, 36 1.58 Excitation current 40 80 240 Excitation voltage 1 2.9 15 9 130/190, 30 125/195, 36 2.38 Excitation current 40 80 240 Excitation voltage 1.2 3.8 17 10 100/140, 30 95/145, 36 1.19 Excitation current 30 120 500 Excitation voltage 0.85 6.8 68 11 90/130, 30 85/135, 36 1.09 Excitation current 30 120 500 Excitation voltage 0.7 6 55 12 90/125, 25 85/130, 31 0.78 Excitation current 30 120 500 Excitation voltage 0.9 7 70 13 80/120, 30 75/125, 36 0.99 Excitation current 200 500 ¡¡ Excitation voltage 20 65 ¡¡ 14 85/115, 30 80/120, 36 0.74 Excitation current 30 120 500 Excitation voltage 0.7 6.5 55 15 85/125, 20 80/130, 26 0.7 Excitation current 30 120 500 Excitation voltage 0.62 5.5 50. wooden case+carton box.
Application areas: Measuring-level current transformer used in power system, transformer used on precision measuring instruments (such as watt-hour meter). According to the requirements of different measurement accuracy of the transformer, different soft magnetic materials can be chosen as iron core materials. The higher the permeability of the iron core is, the smaller the measurement error of the transformer is, hence the accuracy is higher. At present, the most common iron core material is cold-rolled silicon steel sheet, followed by Permalloy and nano-crystalline glass alloy. In recent years, demands for transformers with high-precision level (such as class 0.2, class 0.2Sand class0.5S) increased rapidly. When small ratio, low ampere turns are required or the iron core is restricted because of the small volume, the cold-rolled silicon steel often fails to meet the accuracy requirements. Although the Permalloy iron cores with high permeability can meet the required precision, its price is very high. However use of nano-crystalline alloy iron cores can both meet the accuracy requirements and be produced at lower cost than the Permalloy. Therefore, the demand of measuring level current transformer iron core made of nano-crystalline alloy rapidly increased domestically. The typical parameters comparison of the common soft magnetic materials used for current transformer iron cores: Basic parameters Nano-crystalline iron core Permalloy (1J85) iron core Silicon steel iron core Saturation magnetic flux density (Bs) 1.25T 0.75T 2.03T Initial permeability (¦Ì0) 8¡«12, 104 5¡«8, 104 103 Maximum permeability (¦Ìm) 60, 104 60, 104 4, 104 Curie Temperature (¡æ) 570 400 740 Density (g/cm3) 7.25 8.75 7.65 Lamination factor 0.7 0.9 0.95 Thickness (mm) 0.03 0.15 0.3 Features: It is made of the iron-based nano-crystalline strips with a moderate saturation magnetic induction, high permeability and low loss, which can effectively reduce ratio difference angle difference of the transformer. The saturation magnetic induction Bs of nano-crystalline alloy is between the silicon steel and Permalloy. The lower the Bs value is, the lower the security coefficient of the instrument is. When the system failure occurs and large current through the current transformer results therefore, the iron core is more easily filled, and the secondary current no longer increases in proportion, as can assure that the secondary instruments are well protected and not to be damaged. Permeability of nano-crystalline alloy is close to Permalloy and a magnitude higher than silicon steel, so it is suitable to be made as high-precision transformer iron core. The density and lamination coefficient of nano-crystalline is lower than that of Permalloy, under the condition of the same size and similar performance of the two. In this case the nano-crystalline iron core is 1/4 lighter in weight, and 1/3 lower in the manufacturing cost. In addition, the linear range of nano-crystalline alloy is wider than that of Permalloy .It can work for a long time at temperature of -55 ~ 130 ¡æ ,with a good temperature stability. Specifications a. Rectangular core: (mm) Iron Core Size(mm) (mm) The case size(mm) Weight of the iron Core (kg per piece) Turns Ratio N1: N2 Excitation current(mA) Excitation voltage(mV) 55*97/77*119, 25 50*92/82*114, 30 0.53 1:1 25 0.45 95 2.2 1500 53 70*90/100*120, 30 65*85/105*125, 36 0.81 1:1 200 15 1:1 500 50 75*95/105*125, 25 70*90/110*130, 30 0.7 1:1 70 2 1:1 175 8 80*95/120*135, 25 75*90/125*140, 30 1.09 1:1 80 1.7 1:1 600 41 90*90/160*160, 30 85*85/165*165, 36 2.4 1:1 100 6 1:1 500 100 1:1 1000 140 135*135/260*260, 10 130*130/265*265, 16 2.3 1:1 100 1.5 1:1 500 32 82*602/138*658, 45 75*595/145*665, 55 8.8 1:1 100 1.2 1:1 1000 45 1:1 2000 120 Note: Iron cores of other specifications can be provided upon request of users b. Ring core: No. The iron Core Size Case size(mm) The weight of the iron core (kg per piece) Turns ratio N1: N2 is 1:1; Input current (mA), 50Hz; Output voltage (mV) 1 1105/1165, 15 1095/1175, 25 8.35 Excitation current 450 1200 2000 Excitation voltage 0.59 2.36 5.28 2 415/520, 15 409/526, 23 6.08 Excitation current 50 250 700 Excitation voltage 0.4 3 11 3 305/490, 15 299/496, 23 9.1 Excitation current 350 900 ¡¡ Excitation voltage 5 20 ¡¡ 4 315/395, 35 309/401, 43 8.2 Excitation current 120 400 ¡¡ Excitation voltage 3 11 ¡¡ 5 198/248, 30 192/254, 37 2.76 Excitation current 100 200 500 1000 Excitation voltage 2 6 35 90 6 198/248, 20 192/254, 27 1.84 Excitation current 100 200 500 1000 Excitation voltage 1.5 3.5 25 60 7 155/200, 30 150/205, 36 2 Excitation current 100 190 1000 Excitation voltage 2.5 9.5 80 8 140/180, 30 135/185, 36 1.58 Excitation current 40 80 240 Excitation voltage 1 2.9 15 9 130/190, 30 125/195, 36 2.38 Excitation current 40 80 240 Excitation voltage 1.2 3.8 17 10 100/140, 30 95/145, 36 1.19 Excitation current 30 120 500 Excitation voltage 0.85 6.8 68 11 90/130, 30 85/135, 36 1.09 Excitation current 30 120 500 Excitation voltage 0.7 6 55 12 90/125, 25 85/130, 31 0.78 Excitation current 30 120 500 Excitation voltage 0.9 7 70 13 80/120, 30 75/125, 36 0.99 Excitation current 200 500 ¡¡ Excitation voltage 20 65 ¡¡ 14 85/115, 30 80/120, 36 0.74 Excitation current 30 120 500 Excitation voltage 0.7 6.5 55 15 85/125, 20 80/130, 26 0.7 Excitation current 30 120 500 Excitation voltage 0.62 5.5 50. wooden case+carton box.
Quick Details Place of Origin: Beijing, China (Mainland) Brand Name: HYLITON POWER Model Number: LDZC-10/24/35kV Usage: Current Phase: Single/Three Coil Structure: Toroidal Coil Number: Autotransformer Rated frequency: 50Hz or 60Hz Rated secondary current: 5A or 1A Rated short-time thermal current: 40kA,1s Rated continuous thermal current: 120%In Continuous power-frequency voltage: 3kV , 1min Instrument security factor: FSâ?¤10
1.Features: Double-screw fastening, safe, easy to install, portable Wide inner window, allowing clamping of big cables or bus-bars Wide range of sizes to accommodate all the existing installations 2.Application: Current measurement, monitoring and protection for electrical wiring and equipment. Current and power measurement for electric motors, lighting, air compressheating and ventilation system, air-condition equipment and automation - control system. Current, power and monitoring device. Relay protection device. Company introduction 1.certification We have passed ISO9001:2015,CE,SGS approval and IEC report 2.Company profile Tianjin Grewin is concentrating on transformers for 20 Years and complianted by ISO9001:2015,CB,IEC CB,CE etc.We're always pay great attention to its business philosophy "Quality and Honesty First".Grewin is specialized in the design and manufacture of wound components such as transformer,current sensors, chokes etc .windely used in communications,electronics,meters,industrial control,medical equipments and other fields.We are also a provider of power meters and instruments locators. 85% of its products exported to America, Europe, and Asia etc.We sincerely invite you to join us to create a bright future. 3.Shipping: (1)Products are shipped via UPS / DHL / EMS / HK EMS / FedEx / TNT and so on expresses (door to door). (2)We Provide Drop shipping Service. (3)20 days around delivery upon receiving payment if the qty is lower than 1000PCS and it is not customized products. (4)Shipping via EMS. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country. 4.Payment terms: (1)T/T 100% or 50% deposit by T/T in advance, balance amount to be paid 7 days before delivery. (2) By irrevocable L/C at sight, to be issued immediately against confirmed order. (3)Payment by T/T, if order amount is less than USD 20,000. 5.Warranty: (1)We provide 1 year warranty. (2)If the product is defective, please notify us within 3 days of delivery. (3)All products must be returned on their original condition, in order to qualify for a refund or exchange of goods
CY-KCT02 From 100A~6000A , Secondary current could be 5A 1A .. Features: .High quality compressivemeasurements .Available in a wide range oftransformer ratings .Accuracy up to Class 0.5 .Foot or burbar mounted TypicalApplication: .Switchgear .EnergyManagement Systems .InstrumentationEquipment .SplitCore Current Transformers are designed for assembly to an existing electrical installation no needto dismantle the primary busbar or cables.
The KCT range of split core current transformers have been specifically designed to be small CT and easy to open and yet maintain the accuracy required for kwh meters. The benefit of a split core current transformer is that it can be placed into position easily and without disturbing or disconnecting the main cables it is monitoring.
The KCT range of split core current transformers have been specifically designed to be small CT and easy to open and yet maintain the accuracy required for kwh meters. The benefit of a split core current transformer is that it can be placed into position easily and without disturbing or disconnecting the main cables it is monitoring. The KCT range of current transformers has two insulated terminal covers for connecting the S1 and S2 cables which lock down over the terminal screws fully insulating the connections. This makes it ideal to use Autometers cable hamesses which are colour coded and individually numbered on each conductor ensuring simple and easy connection from the current transformer to the electricity meter.
HK Series split core current transformer is HEYI Electrical current transformer manufacturer newly developed products and the split core CT are designed in particular for esay installation, the quick release button makes the ct the most convenient to fit around cables without cutting off the circuitry. HK current transformer has advantages of bigger capacity and bigger mounting hole size, could be used in more power applications.
SCT range of split core current transformers have been specially designed to facilitate their installation in new or already existing net works. They may be installed without opening any cable or bus-bar circuit. An ineternal precision resistor across the secondary winding of the ct provides a low safe voltage output.
UK Series split-core current transformer has been specially designed to facilitate their installation in new or already existing networks. They may be installed without opening any cable or bus-bar circuit.An internal precision resistor across the secondary winding of the CT provides a low safe voltage output.It can save time and the installations costs. Features Doubie-screw fastening,safe,easy to install,portable. Wide inner window,allowing clamping of big cables or bus-bars. Wide range of sizes to accommodate all the existing installations. Application Current measurement,monitoring and protection for electrical wiring and equipment. Current and power measurement for electric motors,lighting,air compressor,heating and ventilation system,air-condition equipment and automation-control system. Current,power and energy monitoring device. Relay protection device
FEATURES Most cost-effective Faster installation Safe and easy installations High accuracy 0.5 Holding wire diameter: �?16mm Measurement range of 1mA to 200A AC Low phase shift for power measurement Output model: Lead output(2.5m) Isolated plastic case recognized according to UL94-V0 Small-size, compact size, light-weight Over-Voltage protection circuit is installed. CE, UL / EN 61010 - 1 certified PARAMETERS Technical parameters Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 Ratio 1000: 1 or 2000:1 , customized Nominal input current Primary current 20A/30A/40A/50A/60A/80A/100A/150A/200A Overload withstand 1.2 times rated current continuously Accuracy 0.2%, 0.5 %, 1% System Voltage 720V(0.72kV) Output signal 10mA-200mA AC optional 333mV AC or 100mV-2V optional Frequency range 40 Hz-500 Hz Dielectric strength 3KV 50Hz/60Hz at 1 minute Output Standard 2.5 meter cable Protection Level 3.0V0-P Installation Category CAT or CAT 600VAC Max. jaw opening 16 mm Mechanical parameters Dimensions (WDH) (mm) 38mm 55mm 18mm Weight(g) 60 Operating conditions Operating temperature -25C to +55C Relative Humidity 0-85% non-condensing Altitude