Features:
High saturate magnetic induction bs
High initial permeabilityhigh linearity high accuracylow phase and amplitude error for ct
Good temperature stability-55~130
Applying for transformer class grade: 0.5-0.05 class
2applications
High precision current and voltage transformer
Current leakage circuit breakers
Electronic watt hour meter
Precision power meter
Current control in automation industry
Toroidal magnetic cores are made of a Fe-based thin (20 microns) nanocrystalline ribbon and have low loss, high induction of saturation, high operating temperature (up to 150 C), high magnetic permeability. Magnetic cores have a negative temperature coefficient of losses that provides stabilization mode transformer temperature. Application in power high- frequency transformers push-pull,bicyclic SMPS, DC-DC converters, audiotransformers. High permeability provides good electromagnetic connection of windings and low leakage inductance values. HIGHLIGHTS OF THE MATERIAL: Induction amplitude, Bm (25 C) 1,2 T Induction amplitude, Bm (90 C) 1,1 T Curie temperature, Tc 570 C Magnetostriction less than 0,5 x10 ^ -6 Magnetic Permeability (100 kHz) - up to 20,000
KF series split-core current transformers. The CT can be mounted to existing panels, such as control centers or load centers, to measure or monitor voltage. These CTs can be mounted without removing existing cables for easily installation.
The initial magnetic permeability and temperature stability between nanocrystalline soft magnet alloy and permalloy are similar. Under the same conditions of core sizes and characteristics, the weight of the former is much lighter (about 1/3 lighter), cost much lower. Applications: Electronic kwh meter Precise power meter Overcurrent protection in mechanical control apparatus Current control in industrial automation Good thermal stability Paper ctn
Application Current transformers can convert large currents into small currents in a certain proportion, thereby providing current for various instruments and relay protection, and isolating the secondary system from high voltage. This way can protect workers and equipment, can also simplifies and standardizes the manufacture of meters and relays. Advantagesï¼? In order to improve the current transformer precision, has to improve the magnetic permeability of current transformer cores. Compared with silicon steel core, nanocrystalline core has better magnetic permeability. Compared with permalloy core, the cost of nano core is lower. So nano core is the ideal material of current transformer. It is widely used in precision current transformer, zero sequence current transformer, medium and high frequency transformer.
Application Current transformers can convert large currents into small currents in a certain proportion, thereby providing current for various instruments and relay protection, and isolating the secondary system from high voltage. This way can protect workers and equipment, can also simplifies and standardizes the manufacture of meters and relays. Advantages In order to improve the current transformer precision, has to improve the magnetic permeability of current transformer cores. Compared with silicon steel core, nanocrystalline core has better magnetic permeability. Compared with permalloy core, the cost of nano core is lower. So nano core is the ideal material of current transformer. It is widely used in precision current transformer, zero sequence current transformer, medium and high frequency transformer.
Jiangyin Spark XH-SCT-T24 Series split-core current transformer , Diameter 24mm , Max rated current 300A ,output 0.333V ,1.0% class ,UL list Features: Small size, low cost High secondary turns Secure locking hinge Features: Maximum continuous primary current 5A to 300AAC Current Ratio: 3000: 1 Output: 0.333 Volt or mA at rated current Accuracy: �± 1% from 5% to 120% of rated current Insulation Voltage: 600VAC Maximum Primary Voltage: 5000VAC(Insulated Conductor) Phase angle: Less than 2 degrees at 50% of rated current Frequency Range: 50 Hz to 400 Hz Operating Temperature: -15C to 60C. Leads: 4Foot(105cm), UL 1015, Twisted Pair, 0.34 mm2(22AWG) CE recognized, and RoHS compliant Output and leads can be customized
DAQGPCT485 split core current transformer is a kind of current sensor transformer which can convert AC analog signal into RS485 digital signal launched by Shanghai Data Acquisition IOT Technology Co LTD The product has builtin 32bit ARM series MCU and highprecision metering chip and is a multipoint calibrated current conversion module It has the characteristics of high precision and fast response DAQGPCT485 can directly interact with common data acquisition gateways DTU programmable controller PLC and host computer This product is widely used in AC motor lighting equipment air compressor heating ventilation and air conditioning equipment building selfcontrol system equipment OEE open rate industrial Internet rural power transformation projects and other scenarios of current monitoring and acquisition scenarios 2 Service Concept Our company solemnly promise you You buy more than just products but also meticulous and thoughtful technical support We provide free remote guidance remote configuration and commissioning services and send data to the server specified by the customer Free IOT solution consulting services 3 Product Characteristic Parameters Line Sequence Definition Red12V BlackGND Yellow485A White485B Length of LineDefault 1 meter Acquisition Characteristic Current detection range AC 02A100AOther large range transformers can be customized Electrical Characteristic Power supply mode524V DC Operating power consumption05W Operating frequency5060Hz Communication Characteristic Transmission modeRS485 Communication protocol Modbus RTU Structural Characteristic MaterialABS plastic housing Installation methodBuckle mounting Working Environment Temperature 20C70C Storage Environment Temperature 20C80C 4 The Core Advantages of the Product High precision measuring chip high measurement accuracy Open type design easy to install Easy installation and fast deployment helping IOT projects land quickly 5 Description of the Modbus Communication Protocol 51 Serial Port Communication Parameters Baud rate9600 Data bit8 Verify NONE Stop bit1 52 Function Code Definition The upper computer uses 03 function code to read data or receive alarm data The host computer controls the lower machine equipment transformer using 06 function code
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13 Accuracy Class 0.5S, 0.5%, 1%, 3% Range of primary rated current 100-1000A Range of Rated load 10VA Rated frequency 50/60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 150%I1n Secondary winding power frequency withstand voltage 3kV, 1min Safety Factor Rating (FS)
Quick Details Place of Origin: Beijing, China (Mainland) Brand Name: HYLITON POWER Model Number: LDZC-10/24/35kV Usage: Current Phase: Single/Three Coil Structure: Toroidal Coil Number: Autotransformer Rated frequency: 50Hz or 60Hz Rated secondary current: 5A or 1A Rated short-time thermal current: 40kA,1s Rated continuous thermal current: 120%In Continuous power-frequency voltage: 3kV , 1min Instrument security factor: FSâ?¤10