Feature: Electrical and mechanical interlocks prevent cross connection of power sources. Quick change circuit board is easily replaced in the event of failure. No need to disconnect and reinstall the entire unit. Time delay ensures generator voltage is at a stable level before transfer occurs. The time delay can be disabled when an inverter is used as the alternate source. Rugged, heavy-duty, screw-type wiring terminals allow direct connection to contactor for more reliable operation. Heavy Duty metal enclosure with easy to use wiring diagram permanently attached. 1 year limited warranty.
Feature: Electrical and mechanical interlocks prevent cross connection of power sources. Quick change circuit board is easily replaced in the event of failure. No need to disconnect and reinstall the entire unit. Time delay ensures generator voltage is at a stable level before transfer occurs. The time delay can be disabled when an inverter is used as the alternate source. Rugged, heavy-duty, screw-type wiring terminals allow direct connection to contactor for more reliable operation. Heavy Duty metal enclosure with easy to use wiring diagram permanently attached. 1 year limited warranty.
PC Type Load Auto Transfer Switch for Generators It adopted double complex contact/ horizontal pulling mechanism/micro motor energy pre storage and micro-computer control technology, basically come to Zero arc ( no arcing chamber); Adopted reliable mechanical interlock and electric interlock, executive unit adopt independent load disconnect switch, it makes more reliable and safety; Adopt "Zero Position" technology, it can force to set to Zero Position under emergency situation ( cutoff two way power supply, meet the fire linkage requirements; Load disconnect switch change over adopt singleness motor drive, switch over smooth and reliable, no noise, little impact; The driving motor have instant current across only under the load disconnect switch change over, stable working status no need to provide the working current, outstanding energy saving. Executive load disconnect switch have mechanical interlock, make sure the Normal power and Reserve Power working reliable and no interference; Distinct ON and OFF position indicator, padlock function etc., make reliable and safe isolation between power supply and loading. High security, high automatization, high reliability, working life more than 8000 times; Electromechanical integration design, accuracy change over, flexible, smoothly, adopt international advanced logical control technology, high anti-interference ability, no interference outward. Have main power ON, backup power OFF; main power OFF, backup power ON; main and backup power OFF; three working mode (I-o-II); Easy installation, control circuit adopt plug type terminal connection Four operating functions: Emergency manual, motor remote control, emergency OFF under auto control status, auto control operation. Basic Type Switch Control Characteristic Suitable for two way main and backup power system, auto transfer with auto recovery; Can expand functions by outer connection; Auto, Remote, Manual control functions; Delay 0.5s signal detect, avoid miss actuation; Under Auto control status have "O" position remote control; Can with RS-485 communication port ( optional), according to customer required.
PC Type Load Auto Transfer Switch for Generators It adopted double complex contact/ horizontal pulling mechanism/micro motor energy pre storage and micro-computer control technology, basically come to Zero arc ( no arcing chamber); Adopted reliable mechanical interlock and electric interlock, executive unit adopt independent load disconnect switch, it makes more reliable and safety; Adopt "Zero Position" technology, it can force to set to Zero Position under emergency situation ( cutoff two way power supply, meet the fire linkage requirements; Load disconnect switch change over adopt singleness motor drive, switch over smooth and reliable, no noise, little impact; The driving motor have instant current across only under the load disconnect switch change over, stable working status no need to provide the working current, outstanding energy saving. Executive load disconnect switch have mechanical interlock, make sure the Normal power and Reserve Power working reliable and no interference; Distinct ON and OFF position indicator, padlock function etc., make reliable and safe isolation between power supply and loading. High security, high automatization, high reliability, working life more than 8000 times; Electromechanical integration design, accuracy change over, flexible, smoothly, adopt international advanced logical control technology, high anti-interference ability, no interference outward. Have main power ON, backup power OFF; main power OFF, backup power ON; main and backup power OFF; three working mode (I-o-II); Easy installation, control circuit adopt plug type terminal connection Four operating functions: Emergency manual, motor remote control, emergency OFF under auto control status, auto control operation. Basic Type Switch Control Characteristic Suitable for two way main and backup power system, auto transfer with auto recovery; Can expand functions by outer connection; Auto, Remote, Manual control functions; Delay 0.5s signal detect, avoid miss actuation; Under Auto control status have "O" position remote control; Can with RS-485 communication port ( optional), according to customer required.
Features: Electrical and mechanical interlocks prevent cross connection of power sources. Quick change circuit board is easily replaced in the event of failure. No need to disconnect and reinstall the entire unit. Rugged, heavy-duty, screw-type wiring terminals allow direct connection to contactor for more reliable operation. Heavy Duty metal enclosure with easy to use wiring diagram permanently attached. 1 year limited warranty
Features: Electrical and mechanical interlocks prevent cross connection of power sources. Quick change circuit board is easily replaced in the event of failure. No need to disconnect and reinstall the entire unit. Rugged, heavy-duty, screw-type wiring terminals allow direct connection to contactor for more reliable operation. Heavy Duty metal enclosure with easy to use wiring diagram permanently attached. 1 year limited warranty
Generator Load Transfer Switch ATS for Diesel Generators Radin Electric provides ATS design, engineering, and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements. RDQ3NM Series Advantages: 1. There is a reliable mechanical interlock device and electric interlock protection between two MCCB, completely avoid the possibility of two MCCB closed at same time; 2. Intelligentized controller adopt the single chip microcomputer (SCM) as the control core, simple hardware, strong functions, easy extension, high reliability; 3. Intelligent controller circuit layout design adopt power sampling separate with SCM control, from the hardware to overcome the electromagnetic interference; 4. With short circuit, over load protection functions, over-volt & under-volt,phase missing auto transfer function and intelligent alarm function; 5. Auto transfer data by external setting freely, with operation motor protect function; 6. Signal connecting cable have passed FLUKE instrument channel test, anti near crosstalk,attenuation crosstalk and back wave loss, can meet the test criteria for permanent link; 7. The ATS controller installation method provide customer with highly autonomy, ( split installation only need simply connect the attached RJ45 signal cable to the corresponding terminal port);
200A MCCB Automatic Transfer Switch Radin Electric provides ATS design, engineering, and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements. Technical Specification Model RDQ3CM Working Voltage AC400V 50/60Hz Operation Mode Auto and Manual Transfer Mode Auto Transfer with Auto Recovery Auto Transfer without Auto Recovery Grid·Generator Rated Current 100A to 1250A Poles 3P and 4P Color White / Black Controller A / B Type as per customer RDQ3CM series intelligent dual power auto transfer switch (brief as ATS) suitable for emergency power supply system with rated AC voltage 400V, 50/60Hz. When one power source fault, can auto interchange from main power to backup power, no need manual operation, to protect the power supply stability. Mainly apply to the important place which not allow power cutoff such as Hospital, shopping mall, bank, chemical industry, metallurgy, high building, military facilities and fire-fighting etc. Product Structure RDQ3CM series intelligent ATS comprised with two 3P or 4P MCCB and its accessories (Aux. contact,Alarm contact), Mechanical interlocking transmission mechanism, intelligent controller etc. Have two constructions of integral and split type. Integral type is controller and executive unit installed at a same base; Split type is controller installed on the panel and the executive unit installed on the base inside the panel box, a 2m length signal cable connecting the controller with the executive unit.
Radin Electric provides ATS design engineering and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements. a. Control power voltage AC 230V b. Auto Transfer Auto transfer auto recovery auto transfer no auto recovery power grid generator c. Manual transfer Manual main power manual backup power manual OFF d. Isolation lock Off position have isolation function also can padlock locked e. Generator control Generator start and stop f. Fire linkage With passove fire linkage signal to switch OFF the device with one set passive NO feedback contact. g. Display mode Mechanical indication device ON/OFF status operating mode LED device ON/OFF status power status LCD device ON/OFF status power status data setting h. Setting mode Key press operation Chinese/English display interface can set the working mode low voltage value over voltage value delay time auto transfer mode etc. i. Power monitoring ABC three phase over voltage (240 290v adjustable) ABC three phase low voltage (150 200v adjustable) ABC three phase missing monitor j. Delay time Transfer delay (0 300s adjustable) Recovery delay (0 300s adjustable) Generator start stop delay (0 300s adjustable) k. Mounting mode Integated mounting Controller Type A Basic type single phase monitor B. Standard type threee phase monitor fire fighting generator control C Intelligent type three phase monitor fire fighting generator control LCD display D Intelligent type three phase monitor fire fighting generator control split LCD display
Radin Electric  provides ATS design, engineering, and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements. Technical Specification Model RDQ3-63 Working Voltage AC150-265V  50/60Hz Operation Mode Auto and Manual Transfer Mode Auto Transfer with Auto Recovery Transfer time delay 0.2s Fixed / 0~30s adjustable Rated Current 6A to 63A  3P and 4P About ATS RDQ3-63 is CB type dual power transfer switch,mainly apply to the two power systems with neutral line earthed and rated current below 63A, rated voltage 230V,50/60Hz, transfer between two power source when one power source fault,to ensure the power supply reliable and safety. Product Structure RDQ3-63 Series ATS usage category AC-33IB,electrical appliance grade CB class,its structure comprise with two MCB and accessories,mechanical interlock transmission mechanism,automatic controller,motor operation mechanism etc.Meanwhile the MCB inside the ATS have its original over load and short circuit protection function,can also used as ON/OFF and protection of the main circuit. Delivery Terms Shipment & Express & Air express
63A Solar Panel Load Auto Changeover Switch ATS RDQ3NX-A/B/C/D series ATS is our company introduced to the market on 2009, effectively solved the problems of MCB type ATS 's insufficient functions, poor reliability, un-convenient replacement etc., this product have three patent certificates ( Invention patent, Utility models patent, Appearance patent), C/D series is a new type introduced to market on 2010, this product have complete functions, concept innovation, is a unique product among the similar products. Product Structure RDQ3-63-A/B/C/D series ATS comprised with two MCB and accessories, mechanical interlock system, intelligent controller etc. Product have A, B,C,D four type control construction, A type is basic type ( Only provide with auto change auto recovery, phase missing protect, auto/manual control), B type is intelligent type( including the A type functions and have Generator start, fire linkage, time delay functions), C and D type is improved type, increased three phase voltage monitoring function on A and B type. This ATS series circuit breaker keeps the original breaker's overload and short circuit protection function. RDQ3NX Series Advantages: 1. Product with modularized design, executive unit, transmission mechanism, control circuit completely independent, easy for replacement. 2. Mechanical transmission device adopt gear transmission, completely eliminate the possibility of closing at same time; 3. Compact appearance, it is one of the smallest product on the market; 4. The control circuit layout adopt working power and sampling power separate with single chip control, to overcome the electromagnetic interference from the hardware construction; 5. Working power voltage range: AC200-400V; 6. Less power consumption, max. peak power loss 4.8W, only 20% of other similar products; 7. Product have complete functions, with generator start, fire linkage, ON delay functions etc.; 8. Modularized design, good components interchange performance, easy installation; 9. Can use various executive circuit breaker;
63A Solar Panel Load Auto Changeover Switch ATS RDQ3NX-A/B/C/D series ATS is our company introduced to the market on 2009, effectively solved the problems of MCB type ATS 's insufficient functions, poor reliability, un-convenient replacement etc., this product have three patent certificates ( Invention patent, Utility models patent, Appearance patent), C/D series is a new type introduced to market on 2010, this product have complete functions, concept innovation, is a unique product among the similar products. Product Structure RDQ3-63-A/B/C/D series ATS comprised with two MCB and accessories, mechanical interlock system, intelligent controller etc. Product have A, B,C,D four type control construction, A type is basic type ( Only provide with auto change auto recovery, phase missing protect, auto/manual control), B type is intelligent type( including the A type functions and have Generator start, fire linkage, time delay functions), C and D type is improved type, increased three phase voltage monitoring function on A and B type. This ATS series circuit breaker keeps the original breaker's overload and short circuit protection function. RDQ3NX Series Advantages: 1. Product with modularized design, executive unit, transmission mechanism, control circuit completely independent, easy for replacement. 2. Mechanical transmission device adopt gear transmission, completely eliminate the possibility of closing at same time; 3. Compact appearance, it is one of the smallest product on the market; 4. The control circuit layout adopt working power and sampling power separate with single chip control, to overcome the electromagnetic interference from the hardware construction; 5. Working power voltage range: AC200-400V; 6. Less power consumption, max. peak power loss 4.8W, only 20% of other similar products; 7. Product have complete functions, with generator start, fire linkage, ON delay functions etc.; 8. Modularized design, good components interchange performance, easy installation; 9. Can use various executive circuit breaker;
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb Wattage: 10W Blue UV light Lumen: 900-1000lm Color Temperature (CCT): 6500K Input Voltage: AC 90-130V & 220v-240V With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
We supply attractive variety qualitative range of Toilet and Bathroom accessories. Features of our Shower door hinges · CNC machined precision pivot pins · Dimension 90mmx 55mm (varies from hinge to hinge) · Chrome plated, Brushed Nickel, Brass Polished, Polished Chrome, Gold Plated, Oil Rubbed Bronze. · Solid brass, Zinc as per customer choice. · Glass to Glass, wall to Glass shower door hinges. · Closing angles 90°, 135°,180°degree. · Straight edges, beveled edges, round edges. · Glass preparation- Mickey Mouse ear, square and round glass cut. · Glass thickness 8mm-12mm. · Glass door weight 35~36Kgs with two hinges. · Glass door weight 54Kgs with three hinges. · Also available in some models of shower door hinges with adjustable hinges. · Also available in auto- self closing for some models. · Also available in Bi-fold Hinge.